PubMed Health⌕ Search

Biomedical subjects

Angelo A Caputo

Publications and source records attributed to Angelo A Caputo.

21 records · Page 2Linked to original sources

Load transfer by an implant in a sinus-grafted maxillary model.

PURPOSE: This in vitro study determined the stress distribution around an implant placed in a posterior edentulous maxillary model with simulated sinus grafts that had different degrees of stiffness. MATERIALS AND METHODS: The composite photoelastic model with a standard threaded implant consisted of simulated crestal cortical, cancellous, sinus cortical, and grafted bone. The graft maturation process and inherent graft quality were represented in the model by varying the stiffness of the graft. Prior to placement of the simulated graft, axial and inclined loads were applied to the implant The stresses that developed in the supporting structures were analyzed photoelastically. The graft was then placed and the testing procedure was repeated over 4 consecutive days, during which time the simulated graft stiffened. RESULTS: The stress analysis indicated that before placement of the simulated graft, loading on the implant transferred the highest stresses to cortical bone. The presence of the simulated graft transferred stress from the native bone simulants to the simulated grafted bone. DISCUSSION: As the stiffness of the graft increased, a more equitable stress distribution was observed in the multilayer bone surrounding the implant. CONCLUSION: Loading of an implant in a less stiff grafted sinus could lead to overloading of the native bone as well as the maturing grafted bone.

Alveolar Process↗

Dimensional accuracy analysis of implant framework castings from 2 casting systems.

PURPOSE: To compare the dimensional accuracy of implant framework castings from an argon vacuum casting machine with those from a centrifugal casting machine. MATERIALS AND METHODS: Three 4 x 10-mm external hex-type implants (3i/Implant Innovations) were embedded in an acrylic resin block 7 mm apart, with a 2 mm offset of the middle implant. Eight reference points were marked on the implant collars. Twenty implant bar frameworks were waxed with UCLA abutments, invested with a ringless system, and subjected to the same thermal cycle. Ten wax patterns were cast in gold alloy using an oxygen-propane torch and centrifugal casting system; 10 were cast using an argon vacuum casting machine (KDF; Denken). The White 1-screw technique was applied after sequentially tightening the mesial and distal abutment screws to 10 Ncm. Fit of the implant framework castings was evaluated by measuring the marginal opening between the casting and implant at the reference points. These measurements were averaged and statistically compared for differences. RESULTS: The mean marginal openings at the most distant measuring locations from the tightened retaining screw at location 1 was between 44 to 48 microm for the centrifugal system compared to between 28 to 32 mm for KDF (P < .01). For screws tightened at location 3, the mean marginal openings at the most distant measuring locations were between 40 to 51 mm for the centrifugal system compared to between 27 to 29 microm for KDF (P < .01). DISCUSSION: In comparison with the centrifugal casting and oxygen-propane system, the argon vacuum system was more accurate and user friendly and less technique-sensitive. CONCLUSION: The argon vacuum casting machine tested produced more accurate, better fitting implant-supported prosthesis frameworks than a conventional centrifugal casting system. The "1-screw" method of evaluating casting fit was most effective when either of the prostheses' end screws were tightened.

Analysis of Variance↗

Comparing cutting efficiencies of diamond burs using a high-speed electric handpiece.

This study sought to compare the cutting efficiency of different diamond burs on initial use as well as during repeated use, alternating with sterilization. Long, round-end, tapered diamond burs with similar diameter, profile, and diamond coarseness (125-150 microm grit) were used. A high-torque, high-speed electric handpiece (set at 200,000 rpm) was utilized with a coolant flow rate of 25 mL/min. Burs were tested under a constant load of 170 g while cuts were made on a machinable ceramic substrate block. Each bur was subjected to five consecutive cuts for 30 seconds of continuous operation and the cutting depths were measured. All burs performed similarly on the first cut. Cutting efficiencies for three of the bur groups decreased significantly after the first cycle; however, by the fifth cycle, all bur groups performed similarly without any significant differences (p > 0.05). A scanning electron microscope revealed significant crystal loss after each use.

Ceramics↗