Efficiency of the glutaraldehyde test strip for monitoring the concentration of glutaraldehyde in reused solutions for disinfecting endoscopes.

BACKGROUND: Glutaraldehyde has been widely used for low-temperature disinfection of endoscopes. The current practice at Siriraj Hospital is to change the glutaraldehyde solution every 21 days or when the solution appears turbid. The disadvantages of this practice include inadequate disinfection of endoscopes if the concentration of glutaraldehyde in a reused solution is insufficient or wasted if the discarded solution is still active. OBJECTIVE: To determine the efficiency of a glutaraldehyde test strip (GTS) in monitoring the amount of glutaraldehyde in a reused solution for disinfecting endoscopes. METHOD: Reused glutaraldehyde solutions for disinfecting bronchoscopes, gastroscopes and colonoscopes were tested for the concentration of glutaraldehyde with a GTS thrice weekly for the first week and then every working day up to 56 days. If the GTS indicated a concentration of glutaraldehyde > or = 1.8 per cent after 21 days, 5 ml of the solution was taken to the laboratory to determine its mycobactericidal activity. RESULTS: All samples of the reused glutaraldehyde solution up to 56 days with a concentration of > or = 1.8 per cent glutaraldehyde on GTS from testings showed mycobactericidal activity. If the glutaraldehyde solution was reused for up to 28, 42 or 56 days, it could save 9,603; 22,813 and 29,415 baht per year respectively for the gastroscopy and colonoscopy units. The corresponding figures were -949; 2,726 and 4,564 baht per year for the bronchoscopy unit. It is estimated that up to 400,000 baht per year could be saved by adopting the strategy of GTS monitoring in all endoscopy units at Siriraj Hospital. CONCLUSION: The current strategy of discarding reused glutaraldehyde solution in the gastroscopy, colonoscopy and bronchoscopy units at Siriraj Hospital may be inappropriate since the reused solution is still mycobactericidal for up to 56 days.

Bronchoscopes↗

Evaluation of in-house optimized semi-nested PCR and EIA for direct detection of mycobacterial DNA in CSF.

A rapid and correct diagnosis of mycobacterial infections is important for effective patient treatment. Semi-nested-PCR with Fl-16 SOL, 16SOR and 16SNSR primers based on the 16S rRNA gene, under optimized conditions, can detect 499 bp amplified products from all tested mycobacteria. The assay could detect as little as 100 fg of mycobacterial DNA except for rapid growing mycobacteria, whose detection limits ranged from 1 ng to 10 pg. The specificities of the capture probes were assessed with 96 mycobacterial strains (22 species) and 33 nonmycobacterial strains (30 species). The specificities of pAll1, pTbc1 and pMar1 were 94%, 93% and 82%, respectively, and that of pAvi1, pInt1, pChe1 and pFor1 were 100%. The pTbc1 and pAvi1 were tested with DNA from 108 CSF samples, and the sensitivity and specificity of the detection method were 56% and 84% compared to culture and patient histories. The assay should be used for rapid detection and concurrent identification of slow growing mycobacteria without parallel conventional culture verification.

Animals↗