Living autologous heart valves engineered from human prenatally harvested progenitors.

BACKGROUND: Heart valve tissue engineering is a promising strategy to overcome the lack of autologous growing replacements, particularly for the repair of congenital malformations. Here, we present a novel concept using human prenatal progenitor cells as new and exclusive cell source to generate autologous implants ready for use at birth. METHODS AND RESULTS: Human fetal mesenchymal progenitors were isolated from routinely sampled prenatal chorionic villus specimens and expanded in vitro. A portion was cryopreserved. After phenotyping and genotyping, cells were seeded onto synthetic biodegradable leaflet scaffolds (n=12) and conditioned in a bioreactor. After 21 days, leaflets were endothelialized with umbilical cord blood-derived endothelial progenitor cells and conditioned for additional 7 days. Resulting tissues were analyzed by histology, immunohistochemistry, biochemistry (amounts of extracellular matrix, DNA), mechanical testing, and scanning electron microscopy (SEM) and were compared with native neonatal heart valve leaflets. Fresh and cryopreserved cells showed comparable myofibroblast-like phenotypes. Genotyping confirmed their fetal origin. Neo-tissues exhibited organization, cell phenotypes, extracellular matrix production, and DNA content comparable to their native counterparts. Leaflet surfaces were covered with functional endothelia. SEM showed cellular distribution throughout the polymer and smooth surfaces. Mechanical profiles approximated those of native heart valves. CONCLUSIONS: Prenatal fetal progenitors obtained from routine chorionic villus sampling were successfully used as an exclusive, new cell source for the engineering of living heart valve leaflets. This concept may enable autologous replacements with growth potential ready for use at birth. Combined with the use of cell banking technology, this approach may be applied also for postnatal applications.

Absorbable Implants↗

Autologous human tissue-engineered heart valves: prospects for systemic application.

BACKGROUND: Tissue engineering represents a promising approach for the development of living heart valve replacements. In vivo animal studies of tissue-engineered autologous heart valves have focused on pulmonary valve replacements, leaving the challenge to tissue engineer heart valves suitable for systemic application using human cells. METHODS AND RESULTS: Tissue-engineered human heart valves were analyzed up to 4 weeks and conditioning using bioreactors was compared with static culturing. Tissue formation and mechanical properties increased with time and when using conditioning. Organization of the tissue, in terms of anisotropic properties, increased when conditioning was dynamic in nature. Exposure of the valves to physiological aortic valve flow demonstrated proper opening motion. Closure dynamics were suboptimal, most likely caused by the lower degree of anisotropy when compared with native aortic valve leaflets. CONCLUSIONS: This study presents autologous tissue-engineered heart valves based on human saphenous vein cells and a rapid degrading synthetic scaffold. Tissue properties and mechanical behavior might allow for use as living aortic valve replacements.

Absorbable Implants↗

Functional growth in tissue-engineered living, vascular grafts: follow-up at 100 weeks in a large animal model.

BACKGROUND: Living autologous vascular grafts with the capacity for regeneration and growth may overcome the limitations of contemporary artificial prostheses. Particularly in congenital cardiovascular surgery, there is an unmet medical need for growing replacement materials. Here we investigate growth capacity of tissue-engineered living pulmonary arteries in a growing lamb model. METHODS AND RESULTS: Vascular grafts fabricated from biodegradable scaffolds (ID 18+/-l mm) were sequentially seeded with vascular cells. The seeded constructs were grown in vitro for 21 days using biomimetic conditions. Thereafter, these tissue-engineered vascular grafts (TEVGs) were surgically implanted as main pulmonary artery replacements in 14 lambs using cardiopulmonary bypass and followed up for < or = 100 weeks. The animals more than doubled their body weight during the 2-year period. The TEVG showed good functional performance demonstrated by regular echocardiography at 20, 50, 80, and 100 weeks and computed tomography-angiography. In particular, there was no evidence of thrombus, calcification, stenosis, suture dehiscence, or aneurysm. There was a significant increase in diameter by 30% and length by 45%. Histology showed tissue formation reminiscent of native artery. Biochemical analysis revealed cellularity and proteoglycans and increased collagen contents in all of the groups, analogous to those of native vessels. The mechanical profiles of the TEVG showed stronger but less elastic tissue properties than native pulmonary arteries. CONCLUSIONS: This study provides evidence of growth in living, functional pulmonary arteries engineered from vascular cells in a full growth animal model.

Absorbable Implants↗

Modeling the mechanics of tissue-engineered human heart valve leaflets.

Mathematical models can provide valuable information to assess and evaluate the mechanical behavior of tissue-engineered constructs. In this study, a structurally based model is applied to describe and analyze the mechanics of tissue-engineered human heart valve leaflets. The results from two orthogonal uniaxial tensile tests are used to determine the model parameters of the constructs after two, three and four weeks of culturing. Subsequently, finite element analyses are performed to simulate the mechanical response of the engineered leaflets to a pressure load. The stresses in the leaflets induced by the pressure load increase monotonically with culture time due to a decrease in the construct's thickness. The strains, on the other hand, eventually decrease as a result of an increase in the elastic modulus. Compared to native porcine leaflets, the mechanical response of the engineered tissues after four weeks of culturing is more linear, stiffer and less anisotropic.

Biomechanical Phenomena↗

Platelet binding to monocytes increases the adhesive properties of monocytes by up-regulating the expression and functionality of beta1 and beta2 integrins.

Human monocytes adhere to activated platelets, resulting in the formation of platelet-monocyte complexes (PMC). Complex formation depends on the interaction between platelet-displayed P-selectin and the specific ligand for P-selectin on leukocytes, P-selectin glycoprotein ligand-1 (PSGL-1). We have recently shown that monocytes within PMC have increased adhesive capacity to the activated endothelium. To better understand the effect of platelet binding on the capacity of monocytes to adhere to activated endothelium, the P-selectin-PSGL-1 interaction-induced changes in integrin functionality were studied. The binding of platelets to monocytes via P-selectin-PSGL-1 interactions was shown to increase expression and activity of alpha4beta1 and alphaMbeta2integrin, with a concomitant decrease in L-selectin expression. Furthermore, the binding of platelets to monocytes resulted in increased monocyte adhesion to intercellular adhesion molecule-1, vascular cell adhesion molecule-1, and fibronectin. Platelet binding was also responsible for an increase in monocyte transendothelial migration. Similar effects were observed after engagement of PSGL-1 with specific antibodies or with P-selectin immunoglobulin protein. Our data suggest that platelets, by binding via P-selectin to PSGL-1 on monocytes, induce up-regulation and activation of beta1 and beta2integrins and increased adhesion of monocytes to activated endothelium. Hence, monocytes within PMC are in a higher state of activation and may have, therefore, an increased atherogenic capacity.

Antibodies↗

Tissue engineering of human heart valve leaflets: a novel bioreactor for a strain-based conditioning approach.

Current mechanical conditioning approaches for heart valve tissue engineering concentrate on mimicking the opening and closing behavior of the leaflets, either or not in combination with tissue straining. This study describes a novel approach by mimicking only the diastolic phase of the cardiac cycle, resulting in tissue straining. A novel, yet simplified, bioreactor system was developed for this purpose by applying a dynamic pressure difference over a closed tissue engineered valve, thereby inducing dynamic strains within the leaflets. Besides the use of dynamic strains, the developing leaflet tissues were exposed to pre-strain induced by the use of a stented geometry. To demonstrate the feasibility of this strain-based conditioning approach, human heart valve leaflets were engineered and their mechanical behavior evaluated. The actual dynamic strain magnitude in the leaflets over time was estimated using numerical analyses. Preliminary results showed superior tissue formation and non-linear tissue-like mechanical properties in the strained valves when compared to non-loaded tissue strips. In conclusion, the strain-based conditioning approach, using both pre-strain and dynamic strains, offers new possibilities for bioreactor design and optimization of tissue properties towards a tissue-engineered aortic human heart valve replacement.

Aortic Valve↗

Fibrin as a cell carrier in cardiovascular tissue engineering applications.

In cardiovascular tissue engineering approaches, efficient seeding methods are essential. To achieve this and to save time, cells can be encapsulated in gels. Combining the advantages of a gel as a cell carrier with the advantages of a fiber-based scaffold, providing structural integrity to the developing tissue, might offer several advantages. In this study, seeding by using fibrin as a cell carrier is compared to the conventional static seeding method with regard to tissue development. Seeding with fibrin resulted in less loss of soluble collagen into the medium and a more mature extracellular matrix in a shorter period of time. The use of fibrin degradation inhibitors was shown to inhibit extracellular matrix formation, although it did not hamper cell proliferation. The use of fibrin as a cell carrier to seed cells into a fiber-based scaffold may represent a promising, timesaving approach in cardiovascular tissue engineering applications.

Biocompatible Materials↗

Living patches engineered from human umbilical cord derived fibroblasts and endothelial progenitor cells.

OBJECTIVE: A major shortcoming in contemporary congenital heart surgery is the lack of viable replacement materials with the capacity of growth and regeneration. Here we focused on living autologous patches engineered from human umbilical cord derived fibroblasts and endothelial progenitor cells (EPCs) as a ready-to-use cell source for paediatric cardiovascular tissue engineering. METHODS: EPCs were isolated from 20 ml fresh umbilical cord blood by density gradient centrifugation and myofibroblasts were harvested from umbilical cord tissue. Cells were differentiated and expanded in vitro using nutrient media containing growth factors. Before seeding, cell-phenotypes were assessed by immuno-histochemistry. Biodegradable patches fabricated from synthetic polymers (PGA/P4HB) were seeded with myofibroblasts followed by endothelialization with EPCs. All patches were cultured in a perfusion bioreactor. A subgroup of patches was additionally stimulated by cyclic strain. Analysis of the neo-tissues comprised histology, immuno-histochemistry, extracellular matrix (ECM) analysis and biomechanical testing. RESULTS: Endothelial phenotypes of EPCs before seeding were confirmed by Ac-Dil-LDL, CD 31, von-Willebrand-Factor and eNOS staining. Histology of the seeded patches demonstrated layered viable tissue formation in all samples. The cells in the newly formed tissues expressed myofibroblast markers, such as desmin and alpha-SMA. The EPCs derived neo-endothelia showed constant endothelial phenotypes (CD 31, vWF). major constituents of ECM such as collagen and proteoglycans were biochemically detected. Stress-strain properties of the patches showed features of native-analogous tissues. CONCLUSIONS: Living tissue engineered patches can be successfully generated from human umbilical cord derived myofibroblasts and EPCs. This new cell source may enable the tissue engineering of versatile, living, autologous replacement materials for congenital cardiac interventions.

Biocompatible Materials↗

Review article: Tissue engineering of semilunar heart valves: current status and future developments.

Heart valve replacement represents the most common surgical therapy for end-stage valvular heart diseases. One major drawback that all heart valve replacements have in common is the lack of growth, repair, and remodeling capability once implanted into the body. The emerging field of tissue engineering is focusing on the in-vitro generation of functional, living semilunar heart valve replacements. This review presents a state-of-the-art overview of the physiological and biomechanical requirements of semilunar heart valves, focusing on the aortic valve. Moreover, recent heart valve tissue engineering is summarized and future options and improvements on the way towards clinical applications are discussed.

Animals↗

Monitoring local cell viability in engineered tissues: a fast, quantitative, and nondestructive approach.

Assessment of cell viability is a key issue in monitoring in vitro engineered tissue constructs. In this study we describe a fully automated, quantitative, and nondestructive approach, which is particularly suitable for tissue engineering. The approach offers several advantages above existing methods. Living and dead cell numbers can be separately determined for both isolated cells and cells that form networks during tissue formation. Moreover, viability can be locally monitored in time throughout the three-dimensional tissue. The viability assay is based on a dual fluorescent staining technique using CellTracker Green (CTG) for detection of living cells and propidium iodide (PI) for dead cells. CTG and PI images are created with a confocal laser scanning microscope. To determine the number of living cells, CTG fluorescence intensity is determined from the CTG image. Thereby, novel image-processing techniques have been developed, normalizing for various undesired influences that alter measurements of absolute CTG fluorescence intensities. Dead cell numbers are determined from the PI image, using an improved computerized counting method. The approach was first evaluated on C2C12 monolayers, of which images were taken directly after probe addition and 24 h later. Results show that at both times, computed living and dead cell numbers highly correlate with manually counted cell numbers (r > 0.996). Next, the approach was applied for monitoring viability in three-dimensional engineered skeletal muscle tissue constructs, which were subjected to unfavorable environmental conditions. This example illustrated that local viability can be quantitatively, nondestructively, and locally monitored in three-dimensional tissue constructs, making it a promising tool in the field of tissue engineering.

Animals↗