Single acquisition water-fat separation: feasibility study for dynamic imaging.

Water-fat separation can be challenging in the presence of field inhomogeneities. Three-point (3-pt) water-fat separation methods achieve robust performance by measuring and compensating for field inhomogeneities; however, they triple the scan time. The "1+-pt" water-fat separation method proposed in this article for dynamic or repetitive imaging situations combines 3-pt methods' ability to correct for field inhomogeneities with the scan efficiency of a single acquisition method to achieve high temporal and spatial resolutions and robust water-fat separation. Single-echo data are collected with water and fat at a relative phase shift of an odd multiple of pi/2. To correct for undesired phase modulation, phase maps are estimated from a 3-pt calibration scan acquired prior to dynamic imaging. The phase maps are assumed to be slowly varying in time, so they may be used for correcting the phase of the subsequent single-echo signals at the same imaging location. Noise performance was investigated and shown to be equivalent to a single excitation acquisition. The 1+-pt method can also be used in conjunction with parallel imaging. In this situation, the calibration scans required by both methods can be integrated into a shared calibration scan. Promising results were obtained in breast, abdominal, and cardiac imaging applications.

Abdomen↗

Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imaging.

Patient motion remains a primary obstacle to diagnostic image quality, especially in the abdomen, despite the existence of various motion artifact reduction techniques. This work presents a self-navigated motion detection method that can be generalized for most pulse sequences and k-space trajectories. Motion information is extracted directly from raw MR data, requiring no additional gradient or RF pulses, no physiologic monitoring equipment, and minimal--if any--impact on scan time. Initial feasibility results with a two-dimensional gradient echo sequence are shown in phantom studies and in vivo volunteer abdominal studies, demonstrating the sensitivity of the method to both respiratory motion and cardiovascular pulsatility. Prospectively gated images were acquired using the self-navigated data to synchronize image acquisition with motion. These preliminary results suggest that the self-navigated method is a promising technique for reducing motion artifacts in clinical abdominal and cardiac applications.

Abdomen↗

Cine magnetic resonance microscopy of the rat heart using cardiorespiratory-synchronous projection reconstruction.

PURPOSE: To tailor a cardiac magnetic resonance (MR) microscopy technique for the rat that combines improvements in pulse sequence design and physiologic control to acquire high-resolution images of cardiac structure and function. MATERIALS AND METHODS: Projection reconstruction (PR) was compared to conventional Cartesian techniques in point-spread function simulations and experimental studies to evaluate its artifact sensitivity. Female Sprague-Dawley rats were imaged at 2.0 T using PR with direct encoding of the free induction decay. Specialized physiologic support and monitoring equipment ensured consistency of biological motion and permitted synchronization of imaging with the cardiac and respiratory cycles. RESULTS: The reduced artifact sensitivity of PR offered improved delineation of cardiac and pulmonary structures. Ventilatory synchronization further increased the signal-to-noise ratio by reducing inter-view variability. High-quality short-axis and long-axis cine images of the rat heart were acquired with 10-msec temporal resolution and microscopic spatial resolution down to 175 microm x 175 microm x 1 mm. CONCLUSION: Integrating careful biological control with an optimized pulse sequence significantly limits both the source and impact of image artifacts. This work represents a novel integration of techniques designed to support measurement of cardiac morphology and function in rodent models of cardiovascular disease.

Animals↗

Measurement of regional lung function in rats using hyperpolarized 3helium dynamic MRI.

Dynamic regional lung function was investigated in rats using a radial acquisition cine (RA-CINE) pulse sequence together with hyperpolarized (HP) (3)He gas delivered by a constant flow ventilator. Based on regional differences in the behavior of inspired air, the lung was conceptually divided into two regions (the major airways and the peripheral airspace) for purposes of functional analysis. To measure regional function in the major airways, a large RF flip angle (24 degrees) was applied to reduce (3)He magnetization in the peripheral airspace, and signal intensity (SI) was normalized with the projected airway diameter to estimate local airflow. Higher normalized signal intensity was observed in the left branch airway as compared to the right branch airway. To determine regional function in the peripheral airspace, a small RF flip angle (6 degrees) was used. Incremental increases of peripheral SI in successive lung images were consistent with the increase in lung volume. A new "skipping" scanning strategy using dummy frames allows a trade-off between the number of frames acquired for dynamic information, the RF flip angle, and the penetration depth of (3)He magnetization into the lung. This work provides a novel approach to simultaneously assess dynamic regional function and morphology.

Animals↗

Fiber-optic stethoscope: a cardiac monitoring and gating system for magnetic resonance microscopy.

A fundamental problem associated with using the conventional electrocardiograph (ECG) to monitor a subject's cardiac activity during magnetic resonance imaging (MRI) is the distortion of the ECG due to electromagnetic interference. This problem is particularly pronounced in MR microscopy (MRI of small animals at microscopic resolutions (< 0.03 mm(3))) because the strong, rapidly-switching magnetic field gradients induce artifacts in the animal's ECG that often mimic electrophysiologic activity, impairing the use of the ECG for cardiac monitoring and gating purposes. The fiber-optic stethoscope system offers a novel approach to measuring cardiac activity that, unlike the ECG, is immune to electromagnetic effects. The fiber-optic stethoscope is perorally inserted into the esophagus of small animals to optically detect pulsatile compression of the esophageal wall. The optical system is shown to provide a robust cardiac monitoring and gating signal in rats and mice during routine cardiac MR microscopy.

Animals↗