PubMed Health⌕ Search

Biomedical subjects

Anja Hennemuth

Publications and source records attributed to Anja Hennemuth.

3 recordsLinked to original sources

Three-dimensional visualization and virtual simulation of resections in pediatric solid tumors.

PURPOSE: Three-dimensional visualization of solid tumors is possible because of high-resolution computed tomography and magnetic resonance imaging scans. However, additional preoperative information is often desirable in complex malignancies. For the first time, the authors present a model of preoperative 3-dimensional visualization and virtual resections in pediatric solid tumors. METHODS: Image analysis of various pediatric tumors was performed using the research software HepaVision2 (MeVis, Bremen). Organs, tumors, and the vascular system were extracted from multislice computed tomography scans. After hierarchical analysis of the vascular system, territories supplied or drained by the major vascular branches were calculated. Results were explored and virtual resections of organs were carried out using the research software InterventionPlanner (MeVis, Bremen). Data were correlated to intraoperative findings. RESULTS: Four hepatic malignancies, 4 renal tumors, and 3 other neoplasms were analyzed. The technique of 3-dimensional visualization was feasible for all investigated children (mean age 5 years and 9 months). Spatial relations between physiological and pathological structures were identified, and anatomical structures (vessels, tumor tissue, and organ parenchyma) were determined using colorimetric encoding. Virtual simulations of tumor resection were used successfully for planning of surgical procedures in the hepatic and renal tumors. CONCLUSIONS: The technique of 3-dimensional tumor visualization and virtual simulation of tumor resections provides the basis for a successful planning of complex tumor resections in children. The efficiency of these techniques should be further analyzed in series with higher numbers and differentiations of tumors.

Child↗

Determination of cardiac output with multislice spiral computed tomography: a validation study.

OBJECTIVE: To validate and to determine the reproducibility of cardiac output (CO) measurements based on a test-bolus examination in multislice spiral computed tomography (MSCT) in comparison with invasively measured CO using the thermal dilution technique. MATERIAL AND METHODS: In 8 swine, CO was determined by invasive thermal dilution technique and by analysis of enhancement data from dynamic MSCT test-bolus examinations. To assess reproducibility, all MSCT examinations were performed twice. Results were compared using Pearson's correlation coefficient and Bland-Altman plots. RESULTS: Measure by thermal dilution technique CO was 3.71 +/- 1.12 L/min, whereas CO was 3.67 +/- 1.30 L/min using MSCT. Pearson's correlation coefficient was 0.89. The average deviation between MSCT and thermal dilution technique was 0.04 L/min with a standard deviation of 0.59 L/min. There was a good agreement between both MSCT measurements with a mean deviation of -0.03 L/min and a standard deviation of 0.51 L/min. CONCLUSION: CO can reliably be determined from MSCT by means of indicator dilution technique. Measurements are reproducible and provide valuable information on the overall cardiovascular performance without application of additional contrast material or radiation. As this technique does not require time-consuming postprocessing it can be added to routine reporting.

Animals↗

Measurement of cardiac output from a test-bolus injection in multislice computed tomography.

The aim of this study was to assess the feasibility of non-invasive determination of cardiac function from test-bolus data in multislice spiral computed tomography (MSCT). In 25 patients enhancement data gathered from a standardized test-bolus injection were analyzed. The test-bolus examination was performed prior to a retrospectively ECG-gated MSCT of the heart. A time-attenuation curve was obtained in the ascending aorta at the level of the pulmonary arteries. A gamma variate fit was applied to the curve in order to exclude recirculation and get pure first-pass data. Using the known amount of iodine injected, cardiac output (CO), and stroke volume (SV) were determined from integration of the fitted contrast enhancement curve using a reformation of the Stewart-Hamilton equation. Results were compared with CO and SV calculated from the geometric analysis of the retrospectively gated MSCT data using the ARGUS Software (Siemens, Forchheim, Germany). The CO and SV determined from test-bolus analysis and from geometric analysis correlated well with Pearson's correlation coefficients of 0.87 and 0.88, respectively. The standard deviation of the difference between both methods was 0.51 l/min for CO (8.6%) and 11.0 ml for SV (12.3%). Non-invasive quantification of CO seems to be feasible from a standard test-bolus injection. It provides valuable information on cardiac function without additional radiation or application of contrast material.

Cardiac Output↗