PubMed Health⌕ Search

Biomedical subjects

Anna Göransson

Publications and source records attributed to Anna Göransson.

3 recordsLinked to original sources

Inflammatory response to a titanium surface with potential bioactive properties: an in vitro study.

BACKGROUND: The current hard tissue implants research aims to accelerate bone healing by designing surfaces that are bioactive. However, the role of the inflammatory response to these surfaces is so far incompletely described. PURPOSE: The aim of the study was to evaluate early inflammatory response in vitro to a potentially bioactive surface--an anodized surface with Mg ions incorporated (anodized/Mg)--and to compare it to a turned, a blasted, and an anodized surface. MATERIALS AND METHODS: An interferometer was used for topographical characterizations. The disks were incubated with human mononuclear cells. Adherent cells were investigated with respect to number of cells, viability, differentiation, and cytokine production with and without lipopolysaccharide stimulation after 24 and 72 hours. RESULTS: The number of adhered mononuclear cells differed significantly between the different modified surfaces, with the highest number on the anodized surface. However, there were no significant differences in cytokine production and differentiation between the different modified surfaces. The amount of anti-inflammatory mediator interleukin-10 remained over time, while the number of cells and pro-inflammatory cytokine tumor necrosis factor-alpha decreased. The cells were viable on all surfaces, respectively. CONCLUSION: The anodized surfaces with and without Mg ions showed an increased cell adherence, however, otherwise an inflammatory response similar to the turned and blasted surfaces. Furthermore, the potentially bioactive anodized/Mg surface showed a similar response to the TiUnite-like anodized surface despite the former having a surface roughness of a smoother character.

Cell Adhesion↗

Bone formation at titanium implants prepared with iso- and anisotropic surfaces of similar roughness: an in vivo study.

BACKGROUND: Implant surface topography influences the bone response after implantation. However, the importance of surface orientation is not known. PURPOSE: The aim of this study was to investigate the bone tissue response and the stability of titanium implants prepared with isotropic and anisotropic surfaces of similar roughness. MATERIALS AND METHODS: A total of 18 implants were divided into two groups and were inserted into the femurs of nine rabbits for 12 weeks. Confocal laser scanning microscopy was used for the topographic description to verify that the two different surfaces were modified as intended. The stability of the implants was recorded by resonance frequency (RF) measurements at insertion and at time of removal, after which the implants were evaluated histomorphometrically. RESULTS: RF measurements showed that implant stability increased with time. However, there was no significant difference between the two different surface modifications at insertion and after 12 weeks. The histomorphometric comparison revealed no statistically significant differences in regard to either bone-to-metal contact or bone area inside the threads. CONCLUSION: Titanium implants prepared with isotropic and anisotropic surfaces of similar roughness integrate similarly to bone during the 3 months after implantation.

Animals↗

Influence of pH and time on organic substance release from a model dental composite: a fluorescence spectrophotometry and gas chromatography/mass spectrometry analysis.

In this study we assessed the influence of pH and time on the degradation and elution of organic substances from the composite resin material, Z-100. To accomplish this, fluorescence spectrophotometry was evaluated as an appropriate technique for the identification of six organic substances (methacrylic acid, methyl methacrylate, hydroquinone, ethylene glycol dimethacrylate, triethylene glycol dimethacrylate and 4,4'-isopropylidenediphenol) that were eluted from resin composite material stored for 24 h or 6 months at pH 4.0, 6.0 or 8.0. In addition, complementary analyses (solid-phase microextraction/gas chromatography/mass spectrometry) were carried out to identify and quantify the substances. The main substances leached from the resin composite were methacrylic acid, triethylene glycol dimethacrylate and hydroquinone. It was concluded that fluorescence spectrophotometry seems to be a suitable, non-destructive technique for the qualitative analysis of eluted organic components. Critical combinations of time and pH allowed the elution of several organic substances, predominantly methacrylic acid, triethylene glycol dimethacrylate and hydroquinone, from the model resin composite, Z-100.

Acrylates↗