PubMed Health⌕ Search

Biomedical subjects

Anna Maślanka

Publications and source records attributed to Anna Maślanka.

2 recordsLinked to original sources

Densitometric high performance thin-layer chromatography identification and quantitative analysis of psychotropic drugs.

A thin-layer chromatography (TLC)-densitometry method has been developed to identify and quantify haloperidol, amitriptyline, sulpiride, promazine, fluphenazine, doxepin, diazepam, trifluoperazine, clonazepam, and chlorpromazine in selected psychotropic drugs. Separation was performed on precoated silica gel 60 F254 TLC plates. Chromatograms were developed in various mobile phases, and 8 of 30 tested phases were selected based on spot location and developing time. The identification and quantification were carried out based on ultraviolet densitometric measurements at chosen wavelengths. In addition to retention coefficients, the absorption spectra recorded directly from chromatograms were also used in qualitative analysis. Under established experimental conditions, high sensitivity of the method was achieved. The limit of detection ranged from 0.009 to 0.260 microg, depending on the wavelength selected for measuring. A satisfactory recovery, ranging from 92.99 to 104.70%, was achieved for individual constituents.

Amitriptyline↗

Identification and quantitation of polymyxin B, framycetin, and dexamethasone in an ointment by using thin-layer chromatography with densitometry.

A new thin-layer chromatographic-densitometric method has been developed for rapid identification and quantitative determination of polymyxin B, framycetin, and dexamethasone in a dental ointment. Silica gel 60 and F254 silica gel 60 plates were used for separating antibiotics and dexamethasone acetate, respectively. When determining framycetin and polymyxin B, chromatograms were developed by using 2 mobile phases, namely methanol and methanol-n-butanol-ammonia (25%)-chloroform (14 + 4 + 9 + 12, v/v/v/v/). The densitometric measurements were made at 550 nm after detection with 0.3% ninhydrin solution. Dexamethasone was determined by using the mobile phase cyclohexane-ethyl acetate (2 + 3, v/v) and ultraviolet densitometric recording at 245 nm. The results obtained for individual constituents with the chromatographic-densitometric method demonstrate similar accuracy, relative standard deviation values from 1.49 to 2.47%, and relative error values from 0.02 to 0.81% and are comparable to those obtained with the reference methods.

Chromatography, Thin Layer↗