PubMed Health⌕ Search

Biomedical subjects

Anne W Kusterbeck

Publications and source records attributed to Anne W Kusterbeck.

5 recordsLinked to original sources

Self-assembled TNT biosensor based on modular multifunctional surface-tethered components.

We demonstrate a self-assembled reagentless biosensor based on a modular design strategy that functions in the detection of TNT and related explosive compounds. The sensor consists of a dye-labeled anti-TNT antibody fragment that interacts with a cofunctional surface-tethered DNA arm. The arm consists of a flexible biotinylated DNA oligonucleotide base specifically modified with a dye and terminating in a TNB recognition element, which is an analogue of TNT. Both of these elements are tethered to a Neutravidin surface with the TNB recognition element bound in the antibody fragment binding site, bringing the two dyes into proximity and establishing a baseline level of fluorescence resonance energy transfer (FRET). Addition of TNT, or related explosive compounds, to the sensor environment alters FRET in a concentration-dependent manner. The sensor can be regenerated repeatedly through washing away of analyte and specific reformation of the sensor assembly, allowing for subsequent detection events. Sensor dynamic range can be usefully altered through the addition of a DNA oligonucleotide that hybridizes to a portion of the cofunctional arm. The modular design of the sensor demonstrates that it can be easily adapted to detect a variety of different analytes.

Biosensing Techniques↗

Characterization and performance evaluation of in vivo and in vitro produced monoclonal anti-TNT antibodies for the detection of TNT.

In this paper are the experimental results used to characterize four distinct monoclonal anti-TNT antibodies (in vivo and in vitro cloned) for potential use in a field-portable immunosensor. Direct and competitive enzyme-linked immunosorbent assays (ELISA) were performed to determine their affinity for TNT and a fluorescently labeled analog of TNT for use in an immunosensor. Effective concentrations (EC(50)), inhibition concentration (IC(50)) and cross-reactivity measurements to related nitroaromatics (e.g., 2,4,6-trinitrobenzene [TNB], methyl-2,4,6-trinitrophenyl nitramine [tetryl], 2-amino-4,6-dinitrotoluene [2A-4,6-DNT], 2,4-dinitrotoluene [2,4-DNT] and 1,3-dinitrotoluene [1,3-DNT]) were measured. Final characterization of the monoclonal antibodies was based on performance (measured by fluorescence dose response) using a fluorescence-based microcapillary displacement assay. Analytical techniques showed a high degree of affinity for TNT and varying degrees of cross-reactivity with each respective monoclonal antibody. Microcapillary displacement immunoassays with each of the antibodies resulted in detection capabilities at the lowest applied TNT concentration (10 ng/ml).

Animals↗

Detection of 2,4,6-trinitrotoluene in environmental samples using a homogeneous fluoroimmunoassay.

We have tested both soil and water environmental samples for 2,4,6-trinitrotoluene (TNT) using a simple homogeneous assay. This assay is based on changes in fluorescence emission intensity when a fluorescently labeled TNT analogue, bound to an anti-TNT antibody, is competitively displaced by TNT. Fluoroimmunoassay results for TNT concentrations in diluted acetone extracts prepared from archived soils were in good agreement with the results from high-performance liquid chromatography analysis of the same sample extracts. In addition, assays of TNT-spiked environmental well water gave results essentially identical with assays conducted in a TNT-spiked laboratory buffer. The homogeneous fluoroimmunoassay, which is rapid, simple, sensitive, and amenable to high throughput screening, shows promise for near real-time evaluation of TNT contamination in environmental samples.

Chromatography, High Pressure Liquid↗

Non-aerosol detection of explosives with a continuous flow immunosensor.

Contamination of groundwater, soil, and the marine environment by explosives is a global issue. Identification, characterization and remediation are all required for a site recognized as contaminated with 2,4,6-trinitrotoluene (TNT) or hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX). For each step, a method to accurately measure the contaminant level is needed. This paper reviews some of the current methods with emphasis on a single biosensor developed in our laboratory. Current regulatory methods require samples to be sent off-site to a certified laboratory resulting in time delays up to a month. A continuous flow biosensor for detection of explosives has been developed and tested for the rapid field screening of environmental samples. The detection system is based on a displacement immunoassay in which monoclonal antibodies to (TNT) and RDX are immobilized on solid substrates, allowed to bind fluorescently labeled antigens, and then exposed to explosives in aqueous samples. Explosive compounds present in the sample displace proportional amounts of the fluorescent label, which can then be measured to determine the original TNT or RDX concentration. The system can accurately detect ppb to ppt levels of explosives in groundwater or seawater samples and in extracts of contaminated soil. The biosensor has applications in environmental monitoring at remediation sites or in the location of underwater unexploded ordnance.

Aerosols↗

Fabrication of a capillary immunosensor in polymethyl methacrylate.

A method for fabricating capillary-based immunosensors in a coupon milled from an inexpensive, commodity plastic (PMMA, plexiglass) is demonstrated. The key feature of the technique is the use of sol-gel technology to deposit a glass-like (Si [bond] OH) film on surfaces of the plastic capillary channels to facilitate antibody immobilization. The utility of this method was demonstrated in the context of continuous flow displacement immunosensors for the explosive hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX). These sensors exhibited sensitivity to low microg/l RDX concentrations and peak-to-peak signal variations that were generally less than 10% for multiple injections at a single RDX concentration. The useful lifetime of the coupons in these experiments was greater than 10 h even after multiple exposures to high (1000 microg/l) RDX levels. This sensor platform has the physical characteristics needed for a portable field instrument: small, light-weight, and rugged.

Biosensing Techniques↗