PubMed Health⌕ Search

Biomedical subjects

Annelise E Barron

Publications and source records attributed to Annelise E Barron.

At least 19 recordsLinked to original sources

Effects of including an N-terminal insertion region and arginine-mimetic side chains in helical peptoid analogues of lung surfactant protein B.

Surfactant protein B (SP-B) is one of two helical, amphipathic proteins critical for the biophysical functioning of lung surfactant (LS) and hence is an important therapeutic protein. This small, complex 79mer has three internal disulfide bonds and homodimerizes via another disulfide bridge. A helical, amphipathic 25mer from the amino terminus (SP-B(1-25)) exhibits surface-active properties similar to those of full-length, synthetic SP-B. In previous work, we created helical, non-natural mimics of SP-B(1-25) based on sequence-specific peptoid 17mers and demonstrated their biomimetic surface activity. Like SP-B(1-25), the peptoids were designed to adopt helical structures with cationic and nonpolar faces. Here, we compare the surface activities of six different helical peptoid analogues of SP-B(1-25) to investigate the importance of mimicking its N-terminal insertion domain as well as its two arginine residues, both thought to be important for the peptide's proper function. Although the peptoid analogues of SP-B(1-25) studied here share many similar features and all functionally mimic SP-B(1-25) to some degree, it is notable that small differences in their sequences and side chain chemistries lead to substantial differences in their observed interactions with a lipid film. A peptoid comprising a hydrophobic, helical insertion region with aromatic side chains shows more biomimetic surface activity than simpler peptoids, and even better activity, by comparison to natural LS, than SP-B(1-25). However, the substitution of lysine-like side chains for arginine-like side chains in the peptoid has little effect on biomimetic surface activity, indicating that interactions of the guanidino groups with lipids may not be critical for the function of these SP-B mimics.

Arginine↗

A bio-barcode assay for on-chip attomolar-sensitivity protein detection.

Functionalized nanoparticles hold great promise in realizing highly sensitive and selective biodetection. We report a single disposable chip which is capable of carrying out a multi-step process that employs nanoparticles--a bio-barcode assay (BCA) for single protein marker detection. To illustrate the capability of the system, we tested for the presence of prostate specific antigen (PSA) in buffer solution and goat serum. Detection was accomplished at PSA concentrations as low as 500 aM. This corresponds to only 300 copies of protein analytes using 1 microL total sample volume. We established that the on-chip BCA for PSA detection offers four orders of magnitude higher sensitivity compared to commercially available ELISA-based PSA tests.

Animals↗

Self-associating block copolymer networks for microchip electrophoresis provide enhanced DNA separation via "inchworm" chain dynamics.

We describe a novel class of DNA separation media for microchip electrophoresis, "physically cross-linked" block copolymer networks, which provide rapid (<4.5 min) and remarkably enhanced resolution of DNA in a size range critical for genotyping. Linear poly(acrylamide-co-dihexylacrylamide) (LPA-co-DHA) comprising as little as 0.13 mol % dihexylacrylamide yields substantially improved electrophoretic DNA separations compared to matched molar mass linear polyacrylamide. Single-molecule videomicroscopic images of DNA electrophoresis reveal novel chain dynamics in LPA-co-DHA matrixes, resembling inchworm movement, to which we attribute the increased DNA resolution. Substantial improvements in DNA peak separation are obtained, in particular, in LPA-co-DHA solutions at polymer/copolymer concentrations near the interchain entanglement threshold. Higher polymer concentrations yield enhanced separations only for small DNA molecules (<120 base pairs). Hydrophobically cross-linked networks offer advantages over conventional linear polymers based on enhanced separation performance (or speed) and over chemically cross-linked gels because hydrophobic cross-links can be reversibly broken, allowing facile microchannel loading.

DNA↗

A threaded loop conformation adopted by a family of peptoid nonamers.

Non-natural polymers with well-defined three-dimensional folds offer considerable potential for engineering novel functions that are outside the scope of biological polymers. Here we describe a family of N-substituted glycine or "peptoid" nonamers that folds into an unusual "threaded loop" structure of exceptional thermal stability and conformational homogeneity in acetonitrile. The structure is chain-length-specific and relies on bulky, chiral side chains and chain-terminating functional groups for stability. Notable elements of the structure include the engagement of the positively charged amino terminus by carbonyl groups of the backbone through hydrogen bonding interactions and shielding of polar groups from and near-complete exposure of hydrophobic groups to solvent, in a manner resembling a folded polypeptide globular domain turned inside-out. The structure is stable in a variety of organic solvents but is readily denatured in any solvent/cosolvent milieu with hydrogen bonding potential. The structure could serve as a scaffold for the elaboration of novel functions and could be used to test methodologies for predicting solvent-dependent polymer folding.

Circular Dichroism↗

Free-solution electrophoresis of DNA modified with drag-tags at both ends.

In end-labeled free-solution electrophoresis (ELFSE), DNA molecules are labeled with a frictional modifier or "drag-tag", allowing their size-based electrophoretic separation in free solution. Among the interesting observations from early work with dsDNA using streptavidin as a drag-tag was that the drag induced by including a streptavidin label at both ends was significantly more than double that from a single streptavidin (Heller, C. et al.., J. Chromatogr. A 1998, 806, 113-121). This finding was assumed to be in error, and subsequent work focused on experiments in which only a single drag-tag is appended to one end of the DNA molecule. Recent theoretical work (McCormick, L. C., Slater, G. W., Electrophoresis 2005, 26, 1659-1667) has examined the contribution of end-effects to the free-solution electrophoretic mobility of charged-uncharged polymer conjugates, reopening the question of enhanced drag from placing a drag-tag at both ends. In this study, this effect is investigated experimentally, using custom-synthesized ssDNA oligonucleotides allowing the attachment of drag-tags to one or both ends, as well as dsDNA PCR products generated with primers appropriate for the attachment of drag-tags at one or both ends. A range of sizes of drag-tags are used, including synthetic polypeptoid drag-tags as well as genetically engineered protein polymer drag-tags. The enhanced drag arising from labeling both ends has been confirmed, with 6-9% additional drag for the ssDNA and 10-23% additional drag for the dsDNA arising from labeling both ends than would be expected from simply doubling the size of the drag-tag at one end. The experimental results for ssDNA labeled at both ends are compared to the predictions of the recent theory of end-effects, with reasonably good quantitative agreement. These experimental findings demonstrate the feasibility of enhancing ELFSE separations by labeling both ends of the DNA molecule, leading to greater resolving power and a wider range of applications for this technique.

DNA↗

An optimized microchip electrophoresis system for mutation detection by tandem SSCP and heteroduplex analysis for p53 gene exons 5-9.

With the complete sequencing of the human genome, there is a growing need for rapid, highly sensitive genetic mutation detection methods suitable for clinical implementation. DNA-based diagnostics such as single-strand conformational polymorphism (SSCP) and heteroduplex analysis (HA) are commonly used in research laboratories to screen for mutations, but the slab gel electrophoresis (SGE) format is ill-suited for routine clinical use. The translation of these assays from SGE to microfluidic chips offers significant speed, cost, and sensitivity advantages; however, numerous parameters must be optimized to provide highly sensitive mutation detection. Here we present a methodical study of system parameters including polymer matrix, wall coating, analysis temperature, and electric field strengths on the effectiveness of mutation detection by tandem SSCP/HA for DNA samples from exons 5-9 of the p53 gene. The effects of polymer matrix concentration and average molar mass were studied for linear polyacrylamide (LPA) solutions. We determined that a matrix of 8% w/v 600 kDa LPA provides the most reliable SSCP/HA mutation detection on chips. The inclusion of a small amount of the dynamic wall-coating polymer poly-N-hydroxyethylacrylamide in the matrix substantially improves the resolution of SSCP conformers and extends the coating lifetime. We investigated electrophoresis temperatures between 17 and 35 degrees C and found that the lowest temperature accessible on our chip electrophoresis system gives the best condition for high sensitivity of the tandem SSCP/HA method, especially for the SSCP conformers. Finally, the use of electrical fields between 350 and 450 V/cm provided rapid separations (<10 min) with well-resolved DNA peaks for both SSCP and HA.

Acrylic Resins↗

What is the future of electrophoresis in large-scale genomic sequencing?

Although a finished human genome reference sequence is now available, the ability to sequence large, complex genomes remains critically important for researchers in the biological sciences, and in particular, continued human genomic sequence determination will ultimately help to realize the promise of medical care tailored to an individual's unique genetic identity. Many new technologies are being developed to decrease the costs and to dramatically increase the data acquisition rate of such sequencing projects. These new sequencing approaches include Sanger reaction-based technologies that have electrophoresis as the final separation step as well as those that use completely novel, nonelectrophoretic methods to generate sequence data. In this review, we discuss the various advances in sequencing technologies and evaluate the current limitations of novel methods that currently preclude their complete acceptance in large-scale sequencing projects. Our primary goal is to analyze and predict the continuing role of electrophoresis in large-scale DNA sequencing, both in the near and longer term.

Animals↗

The potential of electrophoretic mobility shift assays for clinical mutation detection.

As the understanding of the links between genetic mutations and diseases continues to grow, there is an increasing need for techniques that can rapidly, inexpensively, and sensitively detect DNA sequence alterations. Typically, such analyses are performed on PCR-amplified gene regions. Automated DNA sequencing by capillary array electrophoresis can be used, but is expensive to apply to large numbers of patient samples and/or large genes, and may not always reveal low-abundance mutations in heterozygous samples. Many different types of genetic differences need to be detected, including single-base substitutions and larger sequence alterations such as insertions, deletions, and inversions. Electrophoretic mobility shift assays seem well suited to this purpose and could be used for the efficient screening of patient samples for sequence alterations, effectively reducing the number of samples that must be subjected to full and careful sequencing. While there is much promise, many of the mobility shift assays presently under development have yet to be demonstrated to have the high sensitivity and specificity of mutation detection required for routine clinical application. Hence, further studies and optimization are required, in particular the application of these methods not only to particular genes but also to large numbers of patient samples in blinded studies aimed at the rigorous determination of sensitivity and specificity. This review examines the state-of-the-art of the most commonly used mobility shift assays for mutation detection, including denaturing gradient gel electrophoresis, TGGE, SSCP, heteroduplex analysis, and denaturing HPLC.

DNA Mutational Analysis↗

A modular microfluidic architecture for integrated biochemical analysis.

Microfluidic laboratory-on-a-chip (LOC) systems based on a modular architecture are presented. The architecture is conceptualized on two levels: a single-chip level and a multiple-chip module (MCM) system level. At the individual chip level, a multilayer approach segregates components belonging to two fundamental categories: passive fluidic components (channels and reaction chambers) and active electromechanical control structures (sensors and actuators). This distinction is explicitly made to simplify the development process and minimize cost. Components belonging to these two categories are built separately on different physical layers and can communicate fluidically via cross-layer interconnects. The chip that hosts the electromechanical control structures is called the microfluidic breadboard (FBB). A single LOC module is constructed by attaching a chip comprised of a custom arrangement of fluid routing channels and reactors (passive chip) to the FBB. Many different LOC functions can be achieved by using different passive chips on an FBB with a standard resource configuration. Multiple modules can be interconnected to form a larger LOC system (MCM level). We demonstrated the utility of this architecture by developing systems for two separate biochemical applications: one for detection of protein markers of cancer and another for detection of metal ions. In the first case, free prostate-specific antigen was detected at 500 aM concentration by using a nanoparticle-based bio-bar-code protocol on a parallel MCM system. In the second case, we used a DNAzyme-based biosensor to identify the presence of Pb(2+) (lead) at a sensitivity of 500 nM in <1 nl of solution.

Biochemistry↗

New peptidomimetic polymers for antifouling surfaces.

Exposure of therapeutic and diagnostic medical devices to biological fluids is often accompanied by interfacial adsorption of proteins, cells, and microorganisms. Biofouling of surfaces can lead to compromised device performance or increased cost and in some cases may be life-threatening to the patient. Although numerous antifouling polymer coatings have enjoyed short-term success in preventing protein and cell adsorption on surfaces, none have proven ideal for conferring long-term biofouling resistance. Here we describe a new biomimetic antifouling N-substituted glycine polymer (peptoid) containing a C-terminal peptide anchor derived from residues found in mussel adhesive proteins for robust attachment of the polymer onto surfaces. The methoxyethyl side chain of the peptoid portion of the polymer was chosen for its chemical resemblance to the repeat unit of the known antifouling polymer poly(ethylene glycol) (PEG), whereas the composition of the 5-mer anchoring peptide was chosen to directly mimic the DOPA- and Lys-rich sequence of a known mussel adhesive protein. Surfaces modified with this biomimetic peptide-peptoid conjugate exhibited dramatic reduction of serum protein adsorption and resistance to mammalian cell attachment for over 5 months in an in vitro assay. These new synthetic peptide based antifouling polymers may provide long-term control of surface biofouling in the physiologic, marine, and industrial environments.

Biomimetic Materials↗

Optical monitoring of bubble size and shape in a pulsating bubble surfactometer.

The pulsating bubble surfactometer (PBS) is often used for in vitro characterization of exogenous lung surfactant replacements and lung surfactant components. However, the commercially available PBS is not able to dynamically track bubble size and shape. The PBS therefore does not account for bubble growth or elliptical bubble shape that frequently occur during device use. More importantly, the oscillatory volume changes of the pulsating bubble are different than those assumed by the software of the commercial unit. This leads to errors in both surface area and surface tension measurements. We have modified a commercial PBS through the addition of an image-acquisition system, allowing real-time determination of bubble size and shape and hence the accurate tracking of surface area and surface tension. Compression-expansion loops obtained with the commercially available PBS software were compared with those provided by the image-analysis system for dipalmitoylphosphatidylcholine, Infasurf, and Tanaka lipids (dipalmitoylphosphatidylcholine-palmitoyloleoylphosphatidyl-glycerol-palmitic acid, 68:22:9) at concentrations of 0.1 and 1.0 mg/ml and at frequencies of 1 and 20 cycles/min. Whereas minimum surface tension as determined by the image-analysis system is similar to that measured by the commercially available software, the maximum surface tension and the shapes of the interfacial area-surface tension loops are quite different. Differences are attributable to bubble drift, nonsinusoidal volume changes, and variable volume excursions seen with the modified system but neglected by the original system. Image analysis reveals that the extent of loop hysteresis is greatly overestimated by the commercial device and that an apparent, rapid increase in surface tension upon film expansion seen in PBS loops is not observed with the image-analysis system. The modified PBS system reveals new dynamic characteristics of lung surfactant preparations that have not previously been reported.

Equipment Design↗

Poly(acrylamide-co-alkylacrylamides) for electrophoretic DNA purification in microchannels.

We have created a family of water-soluble block copolymers of acrylamide and N-alkylacrylamides that are designed to selectively remove proteins from DNA via microchannel electrophoresis. It was hypothesized that the inclusion of hydrophobic subunits in the polymer chain, in sufficient concentration, could lead to protein adsorption due to hydrophobic interactions. A series ofN-alkylacrylamide comonomers with varying alkyl chain lengths (C4, C6, C8) and also an N,N-dialkyl group (C6-C6) were synthesized via reactions between acryloyl chloride and the respective alkylamines. Copolymers were synthesized using an aqueous "micellar" polymerization technique, which involves dissolving acrylamide in the aqueous phase while hydrophobic monomers are solubilized in sodium dodecyl sulfate micelles. Copolymers comprising up to 4 mol % of a hydrophobic subunit (as verified by (1)H NMR) were synthesized. Polymer molecular weights were determined by tandem gel permeation chromatography-multiangle laser light scattering, and ranged from 1.5 x 10(6) to 4.3 x 10(6). Capillary electrophoresis analysis of bovine serum albumin and beta-lactoglobulin migration in these matrixes revealed that the octylacrylamide and dihexylacrylamide copolymers show the most significant extent of protein adsorption while butylacrylamides show no noteworthy adsorption trend. All copolymer matrixes studied allowed the passage of a dsDNA digest, and displayed some DNA sieving ability at 0.5% (w/w) in TTE (50 mM Tris, 50 mM TAPS, 2 mM EDTA, pH 8.4) buffer. These matrixes are demonstrated in on-chip experiments to adsorb protein, in a step toward meeting the front-end processing goals of mu-TAS for genetic analysis applications.

Acrylamides↗

Protein polymer drag-tags for DNA separations by end-labeled free-solution electrophoresis.

We demonstrate the feasibility of end-labeled free-solution electrophoresis (ELFSE) separation of DNA using genetically engineered protein polymers as drag-tags. Protein polymers are promising candidates for ELFSE drag-tags because their sequences and lengths are controllable not only to generate monodisperse polymers with high frictional drag, but also to meet other drag-tag requirements for high-resolution separations by microchannel electrophoresis. A series of repetitive polypeptides was designed, expressed in Escherichia coli, and purified. By performing an end-on conjugation of the protein polymers to a fluorescently labeled DNA oligomer (22 bases) and analyzing the electrophoretic mobilities of the conjugate molecules by free-solution capillary electrophoresis (CE), effects of the size and charge of the protein polymer drag-tags were investigated. In addition, the electrophoretic behavior of bioconjugates comprising relatively long DNA fragments (108 and 208 bases) and attached to uncharged drag-tags was observed, by conjugating fluorescently labeled polymerase chain reaction (PCR) products to charge-neutral protein polymers, and analyzing via CE. We calculated the amount of friction generated by the various drag-tags, and estimated the potential read-lengths that could be obtained if these drag-tags were used for DNA sequencing in our current system. The results of these studies indicate that larger and uncharged drag-tags will have the best DNA-resolving capability for ELFSE separations, and that theoretically, up to 233 DNA bases could be sequenced using one of the protein polymer drag-tags we produced, which is electrostatically neutral with a chain length of 337 amino acids. We also show that denatured (unfolded) polypeptide chains impose much greater frictional drag per unit molecular weight than folded proteins, such as streptavidin, which has been used as a drag-tag before.

DNA↗

End-labeled free-solution electrophoresis of DNA.

DNA is a free-draining polymer. This subtle but "unfortunate" property of highly charged polyelectrolytes makes it impossible to separate nucleic acids by free-flow electrophoresis. This is why one must typically use a sieving matrix, such as a gel or an entangled polymer solution, in order to obtain some electrophoretic size separation. An alternative approach consists of breaking the charge to friction balance of free-draining DNA molecules. This can be achieved by labeling the DNA with a large, uncharged molecule (essentially a hydrodynamic parachute, which we also call a drag-tag) prior to electrophoresis; the resulting methodology is called end-labeled free-solution electrophoresis (ELFSE). In this article, we review the development of ELFSE over the last decade. In particular, we examine the theoretical concepts used to predict the ultimate performance of ELFSE for single-stranded (ssDNA) sequencing, the experimental results showing that ELFSE can indeed overcome the free-draining issue raised above, and the technological advances that are needed to speed the development of competitive ELFSE-based sequencing and separation technologies. Finally, we also review the reverse process, called free-solution conjugate electrophoresis (FSCE), wherein uncharged polymers of different sizes can be analyzed using a short DNA molecule as an electrophoretic engine.

DNA↗

Effect of polymer matrix and glycerol on rapid single-strand conformation polymorphism analysis by capillary and microchip electrophoresis for detection of mutations in K-ras gene.

We present the rapid single-strand conformation polymorphism (SSCP) analysis by capillary and microchip electrophoresis to detect the mutations in K-ras gene. Parameters that might affect the analysis of mutation in K-ras gene, such as the polymer and the additive in the sieving matrix, have been studied systematically. Under the optimal conditions, the analysis of seven mutants of K-ras gene could be finished within 10 min by capillary electrophoresis (CE). Furthermore, with the wild-type gene as the inner standard, the analysis accuracy of mutations could be improved. In addition, by studying the properties of polymer solutions, the matrix suitable for microchip electrophoresis was found, and the detection of mutations in K-ras gene could be further shortened to 1 min.

Base Sequence↗

Simple, helical peptoid analogs of lung surfactant protein B.

The helical, amphipathic surfactant protein, SP-B, is a critical element of pulmonary surfactant and hence is an important therapeutic molecule. However, it is difficult to isolate from natural sources in high purity. We have created and studied three different, nonnatural analogs of a bioactive SP-B fragment (SP-B(1-25)), using oligo-N-substituted glycines (peptoids) with simple, repetitive sequences designed to favor the formation of amphiphilic helices. For comparison, a peptide with a similar repetitive sequence previously shown to be a good SP mimic was also studied, along with SP-B(1-25) itself. Surface pressure-area isotherms, surfactant film phase morphology, and dynamic adsorption behavior all indicate that the peptoids are promising mimics of SP-B(1-25). The extent of biomimicry appears to correlate with peptoid helicity and lipophilicity. These biostable oligomers could serve in a synthetic surfactant replacement to treat respiratory distress syndrome.

Circular Dichroism↗

Sparsely cross-linked "nanogel" matrixes as fluid, mechanically stabilized polymer networks for high-throughput microchannel DNA sequencing.

We have developed sparsely cross-linked "nanogels", subcolloidal polymer structures composed of covalently linked, linear polyacrylamide chains, as novel replaceable DNA sequencing matrixes for capillary and microchip electrophoresis. Nanogels were synthesized via inverse emulsion (water-in-oil) copolymerization of acrylamide and a low percentage (approximately 10(-4) mol %) of N,N-methylene bisacrylamide (Bis). Nanogels and nanogel networks were characterized by multiangle laser light scattering and rheometry, respectively, and tested for DNA sequencing in both capillaries and chips with four-color LIF detection. Typical nanogels have an average radius of approximately 230 nm, with approximately 75% of chains incorporating a Bis cross-linker. The properties and performance of nanogel matrixes are compared here to those of a linear polyacrylamide (LPA) network, matched for both polymer weight-average molar mass (M(w)) and the extent of interchain entanglements (c/c). At sequencing concentrations, the two matrixes have similar flow characteristics, important for capillary and microchip loading. However, because of the physical network stability provided by the internally cross-linked structure of the nanogels, substantially longer average read lengths are obtained under standard conditions with the nanogel matrix at a 98.5% accuracy of base-calling (for CE: 680 bases, an 18.7% improvement over LPA, with the best reads as long as 726 bases, compared to 568 bases for the LPA matrix). We further investigated the use of the nanogel matrixes in a high-throughput microfabricated DNA sequencing device consists of 96 separation channels densely fabricated on a 6-in. glass wafer. Again, preliminary DNA sequencing results show that the nanogel matrixes are capable of delivering significantly longer average read length, compared to an LPA matrix of comparable properties. Moreover, nanogel matrixes require 30% less polymer per unit volume than LPA. The addition of a small amount of low molar mass LPA or ultrahigh molar mass LPA to the optimized nanogel sequencing matrix further improves read length as well as the reproducibility of read length (RSD < 1.6%). This is the first report of a replaceable DNA sequencing matrix that provides better performance than LPA, in a side-by-side comparison of polymer matrixes appropriately matched for molar mass and the extent of interchain entanglements. These results could have significant implications for the improvement of microchip-based DNA sequencing technology.

Acrylic Resins↗

A very thin coating for capillary zone electrophoresis of proteins based on a tri(ethylene glycol)-terminated alkyltrichlorosilane.

We describe the use of a tri(ethylene glycol)-terminated alkyltrichlorosilane to create a very thin, protein-resistant "self-assembled monolayer" coating on the inner surface of a fused-silica capillary. The same compound has been demonstrated previously on flat silica substrates to resist adsorption of many proteins. As a covalently bound capillary coating, it displays good resistance to the adsorption of cationic proteins, providing clean separations of a mixture of lysozyme, cytochrome c, ribonuclease A, and myoglobin for more than 200 consecutive runs. Electroosmotic flow (EOF) was measured as a function of pH; the coated capillary retains significant cathodal EOF, with roughly 50% of the EOF of an uncoated capillary at neutral pH, making this coating promising for applications requiring some EOF. The EOF was reasonably stable, with a 2.9% relative standard deviation during a 24 h period consisting of 72 consecutive separations of cationic proteins. Efficiencies for cationic protein separations were moderate, in the range of 190,000-290,000 theoretical plates per meter. The coating procedure was simple, requiring only a standard cleaning procedure followed by a rinse with the silane reagent at room temperature. No buffer additives are required to maintain the stability of the coating, making it flexible for a range of applications, potentially including capillary electrophoresis-mass spectrometry (CE-MS).

Adsorption↗