PubMed Health⌕ Search

Biomedical subjects

Anthony J Hickey

Publications and source records attributed to Anthony J Hickey.

At least 19 recordsLinked to original sources

Investigation of triboelectric charging in dry powder inhalers using electrical low pressure impactor (ELPI).

Electrostatics and triboelectrification phenomena in dry powder inhalers (DPI) are not well understood, but as shown in this study they may play an important role. Using model formulations of albuterol in lactose, the extent of triboelectrification in the operation of DPI was investigated using an electrical low pressure impactor (ELPI). An experimental apparatus was developed, the performance of the ELPI was evaluated for consistency and reproducibility, and compared to a conventional inertial impactor. Using a statistical experimental design the effects of lactose type, drug load, capsule fill, capsule material, and inhaler were assessed. DPI formulations appear to be subject to strong triboelectric effects. Charge separation can occur between different size fractions, i.e. different fractions can carry charges of different sign. In particular, lactose type, inhaler, and capsule material have a strong effect on the magnitude and polarity of the charge developed during DPI operation. The study suggests that the polarity of the aerosol can be controlled by choice of lactose type, capsule material, and inhaler, which could be exploited for targeting different lung physiologies.

Adrenergic beta-Agonists↗

Spray pattern analysis for metered dose inhalers: effect of actuator design.

PURPOSE: This study was conducted to identify the device factors influencing spray pattern and particle size to gain a more complete understanding of spray plume measurements. METHODS: A statistically designed experiment was used to investigate the influence of three actuator features (orifice diameter, expansion chamber depth, and orifice length) on spray pattern and particle size profiles. Custom-built actuators were manufactured and analyzed with laser light sheet illumination methods for spray patterns and laser diffraction for particle size analysis. RESULTS: In addition to orifice size, spray patterns were significantly influenced by the actuator orifice length and sump depth. Particle size analysis of the plumes generated from actuators used in these studies showed that all actuator features (orifice size, length, and sump depth) were significant factors influencing particle size. CONCLUSIONS: The performance of propellant-based metered dose inhaler aerosols seems to be significantly related to sump depth and orifice length, in addition to orifice size. Rational design of propellant-based metered dose inhalers should therefore consider these variables in addition to formulation strategies and simply modifying orifice diameter.

Administration, Inhalation↗

Formulation of a dry powder influenza vaccine for nasal delivery.

The purpose of this research was to prepare a dry powder vaccine formulation containing whole inactivated influenza virus (WIIV) and a mucoadhesive compound suitable for nasal delivery. Powders containing WIIV and either lactose or trehalose were produced by lyophilization. A micro-ball mill was used to reduce the lyophilized cake to sizes suitable for nasal delivery. Chitosan flakes were reduced in size using a cryo-milling technique. Milled powders were sieved between 45 and 125 microm aggregate sizes and characterized for particle size and distribution, morphology, and flow properties. Powders were blended in the micro-ball mill without the ball. Lyophilization followed by milling produced irregularly shaped, polydisperse particles with a median primary particle diameter of approximately 21 microm and a yield of approximately 37% of particles in the 45 to 125 microm particle size range. Flow properties of lactose and trehalose powders after lyophilization followed by milling and sieving were similar. Cryo-milling produced a small yield of particles in the desired size range (<10%). Lyophilization followed by milling and sieving produced particles suitable for nasal delivery with different physicochemical properties as a function of processing conditions and components of the formulation. Further optimization of particle size and morphology is required for these powders to be suitable for clinical evaluation.

Administration, Intranasal↗

Palmitoyl-protein thioesterase 1 deficiency in Drosophila melanogaster causes accumulation of abnormal storage material and reduced life span.

Human neuronal ceroid lipofuscinoses (NCLs) are a group of genetic neurodegenerative diseases characterized by progressive death of neurons in the central nervous system (CNS) and accumulation of abnormal lysosomal storage material. Infantile NCL (INCL), the most severe form of NCL, is caused by mutations in the Ppt1 gene, which encodes the lysosomal enzyme palmitoyl-protein thioesterase 1 (Ppt1). We generated mutations in the Ppt1 ortholog of Drosophila melanogaster to characterize phenotypes caused by Ppt1 deficiency in flies. Ppt1-deficient flies accumulate abnormal autofluorescent storage material predominantly in the adult CNS and have a life span 30% shorter than wild type, phenotypes that generally recapitulate disease-associated phenotypes common to all forms of NCL. In contrast, some phenotypes of Ppt1-deficient flies differed from those observed in human INCL. Storage material in flies appeared as highly laminar spherical deposits in cells of the brain and as curvilinear profiles in cells of the thoracic ganglion. This contrasts with the granular deposits characteristic of human INCL. In addition, the reduced life span of Ppt1-deficient flies is not caused by progressive death of CNS neurons. No changes in brain morphology or increases in apoptotic cell death of CNS neurons were detected in Ppt1-deficient flies, even at advanced ages. Thus, Ppt1-deficient flies accumulate abnormal storage material and have a shortened life span without evidence of concomitant neurodegeneration.

Animals↗

Manufacture, characterization, and pharmacodynamic evaluation of engineered ipratropium bromide particles.

PURPOSE: The intent of this research was to generate and characterize respirable particles of ipratropium bromide (IPB), a short-acting anticholinergic bronchodilator, to achieve demonstrable sustained-release properties. The value of a long-acting anticholinergic agent is evident in the use of tiotropium for the treatment of chronic obstructive pulmonary disease. METHODS: Hollow, spherical particles of ipratropium bromide suitable for inhalation were generated using a spray-drying process and characterized by laser diffraction particle size analysis, scanning electron microscopy, dynamic vapor sorption, X-ray diffraction, differential scanning calorimetry, thermogravimetric analysis, and dissolution testing. Experimental design techniques were used to identify critical process parameters and optimize the spray drying process. Pharmacodynamic studies were conducted to determine duration of effect. RESULTS: Crystalline, stable, respirable particles with a range of dissolution profiles were manufactured by application of polylactic acid (PLA) coatings of 1, 5, 10, 15, 30, and 50% w/w. A novel, robust, modified Type IV dissolution method discriminated between formulations and guided their development. Preliminary studies in guinea pigs indicated an increased duration of bronchodilatory effect for 30% PLA-coated particles (56.3 min) particles compared with IPB powders alone (11.0 min). CONCLUSIONS: Sustained-release respirable particles of ipratropium bromide were developed using a PLA spray coating approach and a trend for increased duration of effect was demonstrated in guinea pigs.

1,2-Dipalmitoylphosphatidylcholine↗

Inhaled azithromycin therapy.

The treatment of pulmonary infectious diseases with pharmaceutical aerosols is an attractive option considering the accessibility of the lungs for topical drug delivery. Aerosols have been targeted to the lungs for the treatment of asthma with great success. Current therapies for other diseases, including Pseudomonas aeruginosa, Pneumocystis jirovecii (formerly Pneumocystis carinii), and mycobacterial infections, remain suboptimal due to the efficacy/safety profile. This may be improved by aerosol targeted pulmonary drug delivery. Azithromycin is a broad spectrum antibiotic that acts by inhibiting protein synthesis. It is associated with side effects that might be avoided by aerosol delivery to the lungs. In the present study three concentrations of azithromycin (10, 50, and 100 mg/mL) were delivered from three nebulizers (Acorn II, Updraft, and LC Plus) operated at 8 L/min. Particles size analyses were conducted by inertial impaction and laser diffraction. In addition, emitted doses were determined. A linear proportionality existed across the concentration range between nominal dose and both fine particle dose/fraction and emitted dose, with R2 > 0.999 in all cases. The mass median aerodynamic diameter increased from 1.4 to 1.9 microm between 10 and 100 mg/mL of azithromycin solution concentration for the Acorn II. The particle size distributions were not all log-normally distributed. The median particle size delivered from the devices was largest for the Updraft (2.8 microm) and smallest for the Acorn II (1.9 microm) for 100 mg/mL azithromycin solution concentrations. The efficiencies of small particle delivery (%<4.7 microm) were as follows, LC Plus = Acorn II (85%) > UpDraft (75%). However, the emitted dose from the LC Plus (55 mg/min) was higher than the Acorn II (31 mg/min) to maximize lung exposure to the aerosol, small median diameters and broad particle size distributions would be most effective. This study demonstrates that the dose delivered to the lungs will be maximized, under the current operating conditions by adopting the LC Plus, and high (100 mg/mL) azithromycin concentrations.

Administration, Inhalation↗

Liposomal dry powders as aerosols for pulmonary delivery of proteins.

The purpose of this research was to develop liposomal dry powder aerosols for protein delivery. The delivery of stable protein formulations is essential for protein subunit vaccine delivery, which requires local delivery to macrophages in the lungs. Beta-glucuronidase (GUS) was used as a model protein to evaluate dry powder liposomes as inhaled delivery vehicles. Dimyristoyl phosphatylcholine:cholesterol (7:3) was selected as the liposome composition. The lyophilization of liposomes, micronization of the powders, aerosolization using a dry powder inhaler (DPI), and in vitro aerodynamic fine particle fraction upon collection in a twin-stage liquid impinger were evaluated. After lyophilization and jet-milling, the total amount of GUS and its activity, representing encapsulation efficiency and stability, were evaluated. The GUS amount and activity were measured and compared with freshly-prepared liposomes in the presence of mannitol, 43% of initial GUS amount, 29% of GUS activity after lyophilization and 36% of GUS amount, 22% of activity after micronization were obtained. Emitted doses from dry powder inhaler were 53%, 58%, 66%, and 73% for liposome powder:mannitol carrier ratios of 1:0, 1:4, 1:9, and 1:19. Fifteen percent of the liposome particles were less than 6.4 mum in aerodynamic diameter. The results demonstrate that milled liposome powders containing protein molecules can be aerosolized effectively at a fixed flow rate. Influences of different cryoprotectants on lyophilization of protein liposome formulations are reported. The feasibility of using liposomal dry powder aerosols for protein delivery has been demonstrated but further optimization is required in the context of specific therapeutic proteins.

Administration, Inhalation↗

Population pharmacokinetic-pharmacodynamic modeling of subcutaneous and pulmonary insulin in rats.

PURPOSE: To develop a population pharmacokinetic-pharmacodynamic (PKPD) model for insulin in rats. METHODS: Rats were administered insulin either subcutaneously (s.c) (0.26,1.3,2.6 U/kg) or by pulmonary route (spray-instillation (s.i)) (0.26,1.3,2.6,13,26 U/kg). Insulin (0.26,1.3,2.6 U/kg) combined with different combinations of hydroxy methyl amino propionic acid (HMAP: 5,10,16,25 mg/kg) was also administered by spray-instillation. Plasma insulin and glucose concentrations at pre-determined time points were measured. Population pharmacokinetic-pharmacodynamic modeling was performed using NONMEM. RESULTS: Insulin exhibited dose-disproportional PK across formulations and routes of administration. The kinetic model suggested monoexponential disposition with simultaneous first order (64%-dimeric form of insulin) - zero order (36%-hexameric form of insulin) absorption. Maximum relative bioavailability (relative to s.c - 0.26 U/kg) of spray-instilled insulin was 46%. Addition of HMAP increased the relative bioavailability of insulin administered via spray-instilled route by 40%. The insulin-glucose relationship was characterized using an indirect response model, wherein, insulin stimulation of glucose uptake into muscle cells was assumed. The basal zero order production rate of glucose (k(G, prod)) was estimated as 0.98 mg/dl/min. The SC50 was fixed at 80 mu U/ml based on literature reports and the S(max) was estimated to be 6. CONCLUSIONS: The proposed PKPD model satisfactorily describes insulin disposition and glucose concentrations across range of doses with and without HMAP.

Adjuvants, Pharmaceutic↗

Dry powder inhaler formulation.

A drug product combines pharmacologic activity with pharmaceutical properties. Desirable performance characteristics are physical and chemical stability, ease of processing, accurate and reproducible delivery to the target organ, and availability at the site of action. For the dry powder inhaler (DPI), these goals can be met with a suitable powder formulation, an efficient metering system, and a carefully selected device. This review focuses on the DPI formulation and development process. Most DPI formulations consist of micronized drug blended with larger carrier particles, which enhance flow, reduce aggregation, and aid in dispersion. A combination of intrinsic physicochemical properties, particle size, shape, surface area, and morphology affects the forces of interaction and aerodynamic properties, which in turn determine fluidization, dispersion, delivery to the lungs, and deposition in the peripheral airways. When a DPI is actuated, the formulation is fluidized and enters the patient's airways. Under the influence of inspiratory airflow, the drug particles separate from the carrier particles and are carried deep into the lungs, while the larger carrier particles impact on the oropharyngeal surfaces and are cleared. If the cohesive forces acting on the powder are too strong, the shear of the airflow may not be sufficient to separate the drug from the carrier particles, which results in low deposition efficiency. Advances in understanding of aerosol and solid state physics and interfacial chemistry are moving formulation development from an empirical activity to a fundamental scientific foundation.

Administration, Inhalation↗

A novel dry powder influenza vaccine and intranasal delivery technology: induction of systemic and mucosal immune responses in rats.

Intranasal (i.n.) vaccination represents an attractive non-invasive alternative to needle-based injection and provides superior protection at mucosal surfaces. However, new formulations are needed to improve efficacy and reduce the refrigerated storage and distribution requirements associated with standard liquid vaccines. Here, we describe a powder formulation of whole inactivated influenza virus and a novel i.n. delivery platform. The powder-formulated vaccine elicited a significant serum antibody response in rats that was at least as strong as that provided by the liquid vaccine administered i.n. or via intramuscular (i.m.) injection. Significant nasal IgA responses were also observed solely after i.n. delivery. This study demonstrates for the first time the generation of potent nasal mucosal and systemic immune responses using an i.n. delivered influenza vaccine powder and suggests an alternative approach to vaccination against influenza and other infectious diseases.

Administration, Intranasal↗

Particle size analysis: AAPS workshop report, cosponsored by the Food and Drug Administration and the United States Pharmacopeia.

The concepts of particle engineering and dosage form design have become dominant themes in pharmaceutical manufacturing. This trend is not simply a reflection of the development of new, more sophisticated manufacturing methods of particles or dispersed systems but also recognition of the importance of quality control even in more traditional manufacturing processes. However, the diversity of particle treatments, methods of particle size analysis, expression and interpretation of data, and process applications results in complicated and sometimes confusing criteria for selection, adoption, or relevance of the available techniques.

Particle Size↗

The influence of formulation and spacer device on the in vitro performance of solution chlorofluorocarbon-free propellant-driven metered dose inhalers.

The purpose of this study was to evaluate the hypothesis that spacer devices have limited effect on the in vitro fine particle dose emitted from solution metered dose inhalers containing different proportions of HFA134a [1,1,1,2,-tetrafluoroethane] propellant. Two solution formulations (80% and 97.5% wt/wt HFA134a) were tested across the actuator alone, actuator plus Aerochamber, and Ace holding chamber. Particle size distributions were determined using laser diffraction (LD) and cascade impaction (CI). Multimodal particle size distributions were identified using LD. CI analyses were characterized by a major mode located at approximately 0.5 microm. The fine particle dose emitted from the inhaler spacer combinations containing 97.5% HFA134a was independent of the device setup used. Fine particle doses were influenced by spacer setup in 80% HFA134a formulations, indicating different plume dynamics of low vapor pressure formulations. Sampling inlet deposition was approximately 0 when spacer devices were used with either formulation. When spacers were not used, sampling inlet deposition was increased significantly. However, inlet deposition with the 97.5% HFA134a formulation was significantly less than that of the 80% HFA134a formulation (approximately 25% of emitted dose compared with 69%, respectively). Thus, high propellant concentration formulations appear to have more robust in vitro performance. This is particularly important given the preponderance of poor patient compliance that is associated with spacer use. High propellant concentrations had the advantage of fine particle doses that were independent of the device setup and significantly lowered sampling inlet deposition when no spacer was used.

Aerosol Propellants↗

Ionic interaction of amiloride and uridine 5'-triphosphate in nebulizer solutions.

Combination therapy using nebulized amiloride hydrochloride and uridine-5'-triphosphate (UTP) trisodium salt aerosols has been investigated for the treatment of cystic fibrosis (CF). Amiloride in aqueous solution precipitates in the presence of UTP, reducing drug concentrations. Interactions between these drugs and NaCl in solution were studied using phase-solubility techniques monitored by UV spectrophotometry. Elemental analyses were employed for precipitate characterization. Amiloride solubility was reduced by more than 85% in saline. Amiloride solubility decreased with increasing UTP concentration, resulting in formation of a precipitated complex. The theoretical molar ratio of complexes range from 1-3 amiloride:1 UTP. At most concentrations only 3 amiloride:1 UTP complex was observed in precipitate. This is a reflection of low Ksp for the 3:1 complex of 2.92 x 10(-11) M4 compared with 2.09 x 10(-4) M2 for amiloride alone. Equilibration over excess bulk solid resulted in higher solubility estimates and different phase solubility diagrams than solubility studies utilizing precipitation technique. This may be explained by the absence of amiloride in the solid state and its impact on complex equilibria with UTP. The solubility suppressing effects of UTP and saline were largely additive. A number of ionic interactions increase complex solubility profile of amiloride hydrochloride in the presence of UTP and NaCl.

Amiloride↗

Aerosol dispersion of respirable particles in narrow size distributions using drug-alone and lactose-blend formulations.

PURPOSE: To examine the effect of formulation type on the aerosolization of respirable particles in narrow size distributions. METHODS: Aerosol dispersion of two formulation types (drug alone and 2% w/w drug-lactose blends) containing micronized or spray-dried fluticasone propionate (FP) particles (d50% = 1.3 to 9.6 microm, GSD = 1.8 to 2.2) were examined using cascade impaction at 60 l/min with low and high resistance inhaler devices: Rotahaler and Inhalator, respectively. RESULTS: The aerosol dispersion of FP particles was significantly affected by the particle size, particle type, inhaler device, and formulation type. Interactions were observed between all factors. Generally, greater powder entrainment was obtained with smaller d50%. Higher emitted doses were obtained from drug-alone formulations of spray-dried FP particles and lactose blends of micronized FP particles. Greater aerosol dispersion of spray-dried FP particles was obtained using lactose-blend formulations with d50% around 4 microm. Greater aerosol dispersion of micronized FP particles was obtained using formulations of drug alone. Larger d50% produced larger mass median aerodynamic diameters. CONCLUSIONS: Small changes in the particle size within the 1-10-microm range exerted a major influence on aerosol dispersion of jet-milled and spray-dried FP particles using drug-alone and lactose-blend formulations.

Administration, Inhalation↗

Aerosol dispersion of respirable particles in narrow size distributions produced by jet-milling and spray-drying techniques.

PURPOSE: To examine the effect of particle size and morphology on aerosol dispersion using jet-milled and spray-dried mannitol particles in narrow size distributions within the respirable range. METHODS: Particle size and morphology were examined by laser diffraction and scanning electron microscopy, respectively. Aerosol dispersion was examined using a cascade impactor with a preseparator operating at a flow rate of 60 L/min, using two inhaler devices: Rotahaler (low-resistance device) and Inhalator (high-resistance device). Powder flow was examined using static and dynamic methods (Carr's compressibility index and vibrating spatula, respectively). RESULTS: Narrow size distributions of jet-milled and spray-dried particles were produced (d50% = 1.4 to 10.3 microm, GSD = 1.8 to 2.1, and d50% = 1.6 to 7.5 microm; GSD = 1.5 to 1.9, respectively). All particles were highly crystalline. Differences in particle shape were observed between jet-milled and spray-dried particles. Higher fine particle fraction (FPF) and relative fine particle fraction (FPFrel) (greater aerosol dispersion) and lower geometric standard deviation (GSD) (less variation) were obtained using particles with d50% between 2 and 5 microm. Higher mass median aerodynamic diameter were obtained with larger d50%. Spray-dried particles produced greater aerosol dispersion compared with jet-milled particles. Greater aerosol dispersion was obtained using the Inhalator than the Rotahaler. CONCLUSIONS: Small changes in the particle size within the 1-10-microm range produced a major impact in the aerosol dispersion of jet-milled and spray-dried particles. Even in these narrow size ranges, aggregation plays an important role in aerosol dispersion.

Administration, Inhalation↗

Development of a size-dependent aerosol deposition model utilising human airway epithelial cells for evaluating aerosol drug delivery.

Aerosol delivery to the airways of the human respiratory tract, followed by absorption, constitutes an alternative route of administration for compounds unsuitable for delivery by conventional oral and parenteral routes. The target for aerosol drug delivery is the airways epithelium, i.e. tracheal, bronchial, bronchiolar and alveolar cells, which become the site of drug deposition. These epithelial layers also serve as a barrier to the penetration of inhaled material. An in vitro model for aerosol deposition and transport across epithelia in the human airways may be a good predictor of in vivo disposition. The present preliminary studies begin an investigation that blends the dynamics of aerosol delivery and the basis of an in vitro simulated lung model to evaluate the transport properties of a series of molecular weight marker compounds across human-derived bronchiolar epithelial cell monolayers. An Andersen viable cascade impactor was used as a delivery apparatus for the deposition of size-segregated particles onto monolayers of small airway epithelial cells and Calu-3 cells. It was shown that these cell layers can withstand placement in the impactor, and that permeability can be tested subsequent to removal from the impactor.

Administration, Inhalation↗

Aerosol generation by metered-dose inhalers containing dimethyl ether/propane inverse microemulsions.

Water soluble compounds were incorporated into metered-dose inhalers (MDIs) by using water-in-propellant lecithin microemulsions, in which dimethyl ether (DME) and propane acted as both continuous phase and propellant. Lecithin, water, and water soluble compounds were added to glass MDI containers, valves were crimped on, and propellants were added using a pressure burette. Aerosols were produced using commercially available actuators, and inertial impaction was used to determine the mass median aerodynamic diameter (MMAD), geometric standard deviation (GSD), and fine particle fraction (FPF) of the resulting aerosols. The DME/propane/lecithin microemulsion MDIs generated aerosols with particle size distributions suitable for pulmonary delivery (eg, MMAD 3.1 microm, FPF 59% for DME with lecithin content 3%, water content 2.5% [wt/wt]). Increasing water concentration (up to 8% wt/wt) was correlated with a reduction in FPF. Freezing and rewarming had no adverse effect on MMAD, GSD, or FPF. Storage of microemulsion samples for up to 3 weeks did not adversely affect the MMAD, GSD, or FPF. This approach may enable the pulmonary delivery of water soluble therapeutic agents via MDIs.

Administration, Inhalation↗

Characterization of Drosophila palmitoyl-protein thioesterase 1.

Batten disease or neuronal ceroid lipofuscinoses (NCL) are a group of genetic neurodegenerative diseases that primarily afflict infants and children and are characterized by progressive loss of brain functions caused by the death of central nervous system (CNS) neurons. The most severe form of the disease is infantile NCL (INCL). INCL is caused by mutations in the palmitoyl-protein thioesterase 1 (PPT1) gene, which encodes a palmitoyl-protein thioesterase 1 enzyme that cleaves long-chain fatty acids from S-acylated proteins within the lysosome. How the loss of this activity causes the death of CNS neurons is not known. A PPT1 homolog and palmitoyl-protein thioesterase 1 enzyme activity were characterized in Drosophila melanogaster as an initial step in developing Drosophila as a model system for studying the etiology of INCL. Predicted gene CG12108 in region 8A2 of the X chromosome is 55% identical and 72% similar to human PPT1 and contains conserved catalytic residues and sites of glycosylation. Northern-blot hybridizations revealed a major 1.5 kb CG12108 transcript in unfertilized eggs, embryos, larvae, pupae, adult head and thorax, ovary, testis, and S2 tissue culture cells, as well as several minor mRNA species in some tissues. Levels of the 1.5 kb transcript were fairly uniform among tissues except in testis, where the transcript was enriched 5-fold. The same tissues also contained palmitoyl-protein thioesterase 1 enzyme activity measured using the fluorometric substrate 4-methylumbelliferyl-6-thiopalmitoyl-beta-D-glucoside. Enzyme activity was highest in testis and varied among the other tissues to a greater extent than did CG12108 message, suggesting that CG12108 is subjected to post-transcriptional regulation. Finally, flies homozygous for a deletion that removes CG12108 and three unrelated neighboring genes had less than 3% of wildtype levels of enzyme activity, consistent with CG12108 encoding functional palmitoyl-protein thioesterase 1 activity and being the fly ortholog of human PPT1. CG12108 has been appropriately renamed Ppt1.

Amino Acid Sequence↗