PubMed Health⌕ Search

Biomedical subjects

Anthony J Sherbondy

Publications and source records attributed to Anthony J Sherbondy.

3 recordsLinked to original sources

CT colonography: influence of 3D viewing and polyp candidate features on interpretation with computer-aided detection.

PURPOSE: To retrospectively determine if three-dimensional (3D) viewing improves radiologists' accuracy in classifying true-positive (TP) and false-positive (FP) polyp candidates identified with computer-aided detection (CAD) and to determine candidate polyp features that are associated with classification accuracy, with known polyps serving as the reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained; this study was HIPAA compliant. Forty-seven computed tomographic (CT) colonography data sets were obtained in 26 men and 10 women (age range, 42-76 years). Four radiologists classified 705 polyp candidates (53 TP candidates, 652 FP candidates) identified with CAD; initially, only two-dimensional images were used, but these were later supplemented with 3D rendering. Another radiologist unblinded to colonoscopy findings characterized the features of each candidate, assessed colon distention and preparation, and defined the true nature of FP candidates. Receiver operating characteristic curves were used to compare readers' performance, and repeated-measures analysis of variance was used to test features that affect interpretation. RESULTS: Use of 3D viewing improved classification accuracy for three readers and increased the area under the receiver operating characteristic curve to 0.96-0.97 (P<.001). For TP candidates, maximum polyp width (P=.038), polyp height (P=.019), and preparation (P=.004) significantly affected accuracy. For FP candidates, colonic segment (P=.007), attenuation (P<.001), surface smoothness (P<.001), distention (P=.034), preparation (P<.001), and true nature of candidate lesions (P<.001) significantly affected accuracy. CONCLUSION: Use of 3D viewing increases reader accuracy in the classification of polyp candidates identified with CAD. Polyp size and examination quality are significantly associated with accuracy.

Adult↗

Alternative input devices for efficient navigation of large CT angiography data sets.

PURPOSE: To compare devices for the task of navigating through large computed tomographic (CT) data sets at a picture archiving and communication system workstation. MATERIALS AND METHODS: The institutional review board approved this study, and all subjects provided informed consent. Five radiologists were asked to find 25 different vascular targets in three CT angiography data sets (average number of sections, 1025) by using several devices (trackball, tablet, jog-shuttle wheel, and mouse). For each trial, the total time to acquire the targets (T1) was recorded. A secondary study in which 13 nonradiologists performed seven trials with an artificial target inserted at a random location in the same image data was also performed. For each trial, the following items were recorded: time until first target sighting (t2), time to manipulate the device after seeing the target, sections traversed during t2 (d1), time from first sight to target acquisition (t4), sections traversed during t4 (d2), and total trial time. Statistical analysis involved repeated-measures analysis of variance (ANOVA) and pairwise comparisons. RESULTS: Repeated-measures ANOVA revealed that the device used had a significant (P < .05) effect on T1. Pairwise comparisons revealed that the trackball was significantly slower than the tablet (P < .05) and marginally slower than the jog-shuttle wheel (P < .10). Further repeated-measures ANOVA for each secondary outcome measure revealed significant differences between devices for all outcome measures (P < .005). Pairwise comparisons revealed the trackball to be significantly slower than the other devices in all measures (P < .05). The trackball was significantly (P < .05) more accurate than the other devices for d1 and d2. CONCLUSION: The trackball may not be the optimal device for navigation of large CT angiography data sets; the use of other existing devices may improve the efficiency of interpretation of these sets.

Angiography↗

Pulmonary nodules on multi-detector row CT scans: performance comparison of radiologists and computer-aided detection.

PURPOSE: To compare the performance of radiologists and of a computer-aided detection (CAD) algorithm for pulmonary nodule detection on thin-section thoracic computed tomographic (CT) scans. MATERIALS AND METHODS: The study was approved by the institutional review board. The requirement of informed consent was waived. Twenty outpatients (age range, 15-91 years; mean, 64 years) were examined with chest CT (multi-detector row scanner, four detector rows, 1.25-mm section thickness, and 0.6-mm interval) for pulmonary nodules. Three radiologists independently analyzed CT scans, recorded the locus of each nodule candidate, and assigned each a confidence score. A CAD algorithm with parameters chosen by using cross validation was applied to the 20 scans. The reference standard was established by two experienced thoracic radiologists in consensus, with blind review of all nodule candidates and free search for additional nodules at a dedicated workstation for three-dimensional image analysis. True-positive (TP) and false-positive (FP) results and confidence levels were used to generate free-response receiver operating characteristic (ROC) plots. Double-reading performance was determined on the basis of TP detections by either reader. RESULTS: The 20 scans showed 195 noncalcified nodules with a diameter of 3 mm or more (reference reading). Area under the alternative free-response ROC curve was 0.54, 0.48, 0.55, and 0.36 for CAD and readers 1-3, respectively. Differences between reader 3 and CAD and between readers 2 and 3 were significant (P < .05); those between CAD and readers 1 and 2 were not significant. Mean sensitivity for individual readings was 50% (range, 41%-60%); double reading resulted in increase to 63% (range, 56%-67%). With CAD used at a threshold allowing only three FP detections per CT scan, mean sensitivity was increased to 76% (range, 73%-78%). CAD complemented individual readers by detecting additional nodules more effectively than did a second reader; CAD-reader weighted kappa values were significantly lower than reader-reader weighted kappa values (Wilcoxon rank sum test, P < .05). CONCLUSION: With CAD used at a level allowing only three FP detections per CT scan, sensitivity was substantially higher than with conventional double reading.

Adolescent↗