PubMed Health⌕ Search

Biomedical subjects

Antonello De Martino

Publications and source records attributed to Antonello De Martino.

6 recordsLinked to original sources

Application of Mueller polarimetry in conical diffraction for critical dimension measurements in microelectronics.

Fast and efficient metrology tools are required in microelectronics for control of ever-decreasing feature sizes. Optical techniques such as spectroscopic ellipsometry (SE) and normal incidence reflectometry are widely used for this task. In this work we investigate the potential of spectral Mueller polarimetry in conical diffraction for the characterization of 1D gratings, with particular emphasis on small critical dimensions (CDs). Mueller matrix spectra were taken in the visible (450-700 nm) wavelength range on a photoresist grating on a Si substrate with 70/240 nm CD/period nominal values, set at nine different azimuthal angles. These spectra were fitted with a rigorous coupled-wave analysis (RCWA) algorithm by using different models for the grating profile (rectangular and trapezoidal, with or without rounded corners). A detailed study of the stability and consistency of the optimal CD values, together with the variation of the merit function (the mean square deviation D2) around these values, clearly showed that for a given wavelength range, this technique can decouple some critical parameters (e.g., top and bottom CDs, left and right sidewall projections) much more efficiently than the usual SE.

Journal Article↗

Mueller polarimetric imaging system with liquid crystals.

We present a new polarimetric imaging system based on liquid-crystal modulators, a spectrally filtered white-light source, and a CCD camera. The whole Mueller matrix image of the sample is measured in approximately 5 s in the transmission mode. The instrument design, together with an original and easy-to-operate calibration procedure, provides high accuracy over a wide spectral range (500-700 nm). This accuracy has been assessed by measurement of a linear polarizer at different orientations and a thick wedged quartz plate as an example of a partially depolarized retarder. Polarimetric images of a stained hepatic biopsy with significant fibrosis have been taken at several wavelengths. The optical properties of Picrosirius Red stained collagen (diattenuation, retardance, and polarizance) have been measured independently from each other between 500 and 700 nm.

Collagen↗

Characterization of bidimensional gratings by spectroscopic ellipsometry and angle-resolved Mueller polarimetry.

We studied two bidimensional square gratings of square holes formed in photoresist layers deposited on silicon wafers, both by classical spectroscopic ellipsometry (1.5-4.5-eV spectral range) at a constant incidence angle (70.7 degrees) and by angle-resolved Mueller polarimetry at a constant wavelength (532 nm). The grating period was 1 microm in both directions, and the nominal hole sizes were 250 and 500 nm, respectively. The ellipsometric spectra were fitted by rigorous coupled-wave analysis simulations with two adjustable parameters, the resist layer thickness and the hole size. These parameters were found to be in good agreement with independent scanning electron microscopy measurements. The experimental angle-resolved Mueller spectra were remarkably well reproduced by the simulations, showing that angle-resolved Mueller polarimetry has a great potential for grating metrology applications.

Journal Article↗

Optimized Mueller polarimeter with liquid crystals.

We demonstrate a Mueller polarimeter in which the polarization-state generator and analyzer are both composed of a linear polarizer and two liquid-crystal variable retarders. The polarimeter is designed to optimize the accuracy of the final results by minimization of the condition numbers of the modulation and analysis matrices. The polarimeter calibration, a difficult task by conventional procedures, is achieved easily by use of the eigenvalue method of Compain et al. [Appl. Opt. 38, 3490 (1999)]. The overall polarimeter performance is tested with a linear polarizer at various angles and a compensator at various retardations.

Journal Article↗

Application of Fourier transform infrared ellipsometry to assess the concentration of biological molecules.

Spectroscopic ellipsometry is a noninvasive optical characterization technique mainly used in the semiconductor field to characterize bare substrates and thin films. In particular, it allows the gathering of information concerning the physical structure of the sample, such as roughness and film thickness, as well as its optical response. In the mid-infrared (IR) range each molecule exhibits a characteristic absorption fingerprint, which makes this technique chemically selective. Phase-modulated IR ellipsometry does not require a baseline correction procedure or suppression of atmospheric CO2 and water-vapor absorption bands, thus greatly reducing the subjectivity in data analysis. We have found that ellipsometric measurements of thin films, such as the solid residuals left on a plane surface after evaporation of a liquid drop containing a given compound in solution, are particularly favorable for dosing purposes because the intensity of IR absorptions shows a linear behavior along a wide range of solution concentrations of the given compound. Our aim is to illustrate with a concrete example and to justify theoretically the linearity experimentally found between radiation absorption and molecule concentration. For the example, we prepared aqueous solutions of glycogen, a molecule of huge biological importance currently tested in biochemical analyses, at concentrations ranging from 1 mg/l to 1 g/l which correspond to those found in physiological conditions. The results of this example are promising for the application of ellipsometry for dosing purposes in biochemistry and biomedicine.

Glycogen↗

Full-field optical coherence tomography with thermal light.

A simple optical coherence tomography system has been developed based on a white-light Linnik interferometric microscope with its reference mirror mounted on a piezoelectric translator. The geometrical extension of the optics allows efficient illumination of this device with a low-power (3-W) light bulb, yielding full-field interferometric images at 50 Hz with a fast CCD camera. Owing to the very broad spectral width of the light source and of the camera response, we achieved axial resolutions equal to 1.1 microm in free space and 0.7 microm through a standard microscope cover plate. Tomographic images of an epithelial cell smear and of an hematological sample are shown.

Hot Temperature↗