4 recordsLinked to original sources

Burn depths evaluation based on active dynamic IR thermal imaging--a preliminary study.

Proper diagnostic assessment of burn wound depth is of the highest importance in selecting the mode of burn wound treatment. Several diagnostic methods--clinical and histopathological evaluation, as well as methods employing IR imaging--static thermography and active dynamic thermography (ADT)--are compared on the basis of in vivo experiments conducted on three domestic pigs (23 burn wounds). ADT is presented here as a new, reliable and quantitative method of assessing burn wound depth on the basis of discrimination of the thermal properties of burnt tissue. In the case of ADT registration of thermal images was performed following thermal pulse excitation. A series of captured infrared images was used as the basis for calculating the thermal time constant tau for each pixel. The parameter values were compared with histopathological and clinical assessments of burn depth. The mean value of tau was found for burns, which heal within 3 weeks (tau=12.08+/-1.94s) and for burns, which did not heal during this period (tau=9.07+/-0.68s), p<0.05. The accuracy, sensitivity and specificity of all the methods tested were compared, the best results coming from ADT. The ADT method is fast, non-invasive and relatively inexpensive, although it still requires further animal experimentation as well as clinical study to confirm the results.

Animals↗

A six-ring probe for monitoring conductivity changes.

This paper presents the construction of a six-ring probe for monitoring immittance changes. The spatial sensitivity of the probe is defined. This is used to examine the uniqueness of the probe in terms of its application to monitoring conductivity changes. A spatial distribution of the sensitivity is presented for isotropic and anisotropic cases. The latter case is restricted only to anisotropy met when measuring muscles, i.e. diagonal anisotropy. Theoretical calculations performed using the finite element method were verified experimentally using a specially developed measuring system. An example of in vivo measurements is included.

Animals↗

Static thermography revisited--an adjunct method for determining the depth of the burn injury.

The aim of the study was to investigate the relationship between the static thermography figure of merit DeltaT (the difference in mean values of skin area temperature for the burn wound area and the unaffected reference skin area) and a means of burn classification which would be most suitable for the choice of treatment. The work was an in vivo animal experiment. Statistical analysis showed a high correlation between the DeltaT parameter and histopathological assessment. With regard to the choice of treatment, the most useful correlation was found to be that between DeltaT and the classification of burn wounds into those healed in 3 weeks and those unhealed. The results of this study have revealed a quantitative criterion DeltaT for burn classification. The study suggests that particular burn centres using static thermography use a DeltaT parameter based on their own values for burn classification so as to group burn wounds into those that healed in 3 weeks and those that did not heal. This criterion should be independent of and replace other classification systems. A criterion for the proper choice of burn treatment would then be made more readily available.