PubMed Health⌕ Search

Biomedical subjects

Antonio Guirao

Publications and source records attributed to Antonio Guirao.

12 recordsLinked to original sources

Image metrics for predicting subjective image quality.

PURPOSE: Despite the proliferation of wavefront sensors to characterize the optical quality of individual eyes, there is not yet an accurate way to determine from a wave aberration how severely it will impact the patient's vision. Some of the most commonly used metrics, such as RMS wavefront error and the Strehl ratio, predict subjective image quality poorly. Our goal is to establish a better metric to predict subjective image quality from the wave aberration. METHODS: We describe three kinds of experiments designed to compare the effectiveness of different metrics in determining the subjective impact of the wave aberration. Subjects viewed a visual stimulus through a deformable mirror in an adaptive optics system that compensated for the subject's wave aberration. In the first experiment, we show that some Zernike modes such as spherical aberration and defocus interact strongly in determining subjective image quality. In the second experiment, the subject's wave aberration was replaced by the wave aberration corresponding to an individual Zernike mode. The subject then adjusted the coefficient of the Zernike mode to match the blur of a standard stimulus. In the third experiment, the subject viewed the same stimulus through the wave aberration of one of 59 different postoperative patients who had undergone LASIK and matched the blur by adjusting defocus. We then determined which among many image quality metrics best predicted these matching data. RESULTS: RMS wavefront error was a poor predictor of the data, as was the Strehl ratio. CONCLUSIONS: The neural sharpness metric best described the subjective sharpness of images viewed through the wave aberrations of real eyes. This metric can provide a single number that describes the subjective impact of each patient's wave aberration and will also increase the accuracy of refraction estimates from wavefront-based autorefractors and phoropters.

Humans↗

Corneal aberrations before and after small-incision cataract surgery.

PURPOSE: To study the effect of small-incision cataract surgery on the optical aberrations of the cornea. METHODS: Corneal topography was measured before and after cataract surgery on 70 eyes of 70 patients. Monofocal foldable IOLs were implanted after phacoemulsification through a clear-cornea, 3.5-mm incision without suture. Corneal aberrations, up to the fifth order and 6-mm pupil, were calculated by ray-tracing from the corneal topography. Pre- and postoperative aberrations were compared in each patient and the optical changes induced by surgery investigated. RESULTS: The root mean square of the wave aberration slightly increased on average after surgery (pre, 0.65 +/- 0.46 microm; post, 0.85 +/- 0.63 microm). Most aberration terms were similar, averaged across the 70 patients, before and after surgery (spherical aberration: pre, 0.32 +/- 0.12 microm, and post, 0.34 +/- 0.19 microm; astigmatism: pre, 0.9 +/- 0.8 D, and post, 1.1 +/- 1.0 D; coma: pre, 0.27 +/- 0.18 microm, and post, 0.32 +/- 0.33 microm). However, in each patient, there were changes after surgery in the magnitude (either increasing or decreasing) and/or orientation of aberrations. The mean induced astigmatism was -1.0 +/- 0.9 D at the orientation of the surgical meridian. Induced trefoil also showed a predominant pattern at this direction. Patients with nasal incisions experienced larger changes. CONCLUSIONS: Small-incision surgery does not systematically degrade the optical quality of the anterior corneal surface. However, it introduces changes in some aberrations, especially in nonrotationally symmetric terms such as astigmatism, coma, and trefoil. The incision site plays a main role in the corneal changes after surgery.

Adult↗

A method to predict refractive errors from wave aberration data.

We explored the impact of the eye's higher-order aberrations on subjective refraction comparing two classes of methods for estimating refractive state, one based directly on the wave aberration defined in the pupil plane and another based on the retinal image plane. The method defined in the pupil plane chose the sphere and cylinder that either minimized the wave aberration root mean square or minimized the sum of all the spherical and cylindrical components in the wave aberration. The method defined in the image plane chose the sphere and cylinder that optimized an image-quality metric such as the Strehl intensity ratio, the entropy and the intensity variance of the point-spread function, the volume under the modulation transfer function, or the volume under the contrast-sensitivity function. All these methods were compared in a population of six eyes for which we measured both the wave aberration with a Shack-Hartmann wavefront sensor and the subjective refraction under identical conditions. Pupil plane methods predicted subjective refraction poorly. The mean absolute error of the prediction, in spherical equivalent, was about 0.5 D (range, 0.1 to 0.8 D) and increased with increases in higher-order aberrations. However, for all the retinal image plane methods, the mean error between predicted and subjective refraction was about 0.1 D (range, 0 to 0.25 D). The reliability of the method based on the image-quality optimization was further confirmed in a large population of 146 eyes. In conclusion, higher-order aberrations influence the amount of sphere and cylinder required to correct vision. The results indicate that subjective refraction can be predicted from the eye's optics alone by optimizing computed retinal image quality.

Adult↗

Corneal optical aberrations and retinal image quality in patients in whom monofocal intraocular lenses were implanted.

OBJECTIVES: To compare retinal image quality and optical corneal aberrations in patients in whom monofocal polymethyl methacrylate intraocular lenses (IOLs) were implanted with those in healthy subjects of a similar older age (60-70 years old) and to use the results to suggest improved optical designs of IOLs to maximize retinal image quality. METHODS: A double-pass apparatus was used to measure retinal image quality for 3-, 4-, and 6-mm pupil diameters. Corneal aberrations for a 4-mm pupil were calculated by a ray-tracing technique from the elevations provided by corneal topography. Two groups of 20 subjects of a similar older age were studied: in one group, polymethyl methacrylate monofocal IOLs were implanted; and in a second group, healthy subjects were used as a reference. RESULTS: The average retinal image quality was similar in older healthy patients and in patients in whom IOLs were implanted, with both groups having a significantly worse image quality than healthy younger subjects (aged 20-30 years). Both groups were more tolerant to defocus than younger subjects. CONCLUSIONS: The average retinal image quality of patients in whom IOLs were implanted was worse than that of healthy younger subjects despite the good optical quality of isolated IOLs. This apparent paradox can be understood by the nature of the aberration coupling in the eyes that undergo implantation. The ideal substitute for the natural lens is not an IOL with the best-isolated optical performance, but rather one designed to compensate for the aberrations of the cornea-a design somehow inspired by the crystalline lens of younger subjects.

Aged↗

Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes.

We calculated the impact of higher-order aberrations on retinal image quality and the magnitude of the visual benefit expected from their correction in a large population of human eyes. Wave aberrations for both eyes of 109 normal subjects and 4 keratoconic patients were measured for 3-, 4-, and 5.7-mm pupils with a Shack-Hartmann sensor. Retinal image quality was estimated by means of the modulation transfer function (MTF) in white light. The visual benefit was calculated as the ratio of the MTF when the monochromatic higher-order aberrations are corrected to the MTF corresponding to the best correction of defocus and astigmatism. On average, the impact of the higher-order aberrations for a 5.7-mm pupil in normal eyes is similar to an equivalent defocus of approximately 0.3 D. The average visual benefit for normal eyes at 16 c/deg is approximately 2.5 for a 5.7-mm pupil and is negligible for small pupils (1.25 for a 3-mm pupil). The benefit varies greatly among eyes, with some normal eyes showing almost no benefit and others a benefit higher than 4 at 16 c/deg across a 5.7-mm pupil. The benefit for keratoconic eyes is much larger. The benefit at 16 c/deg is 12 and 3 for 5.7- and 3-mm pupils, respectively, averaged across four keratoconics. These theoretical benefits could be realized in normal viewing conditions but only under specific conditions.

Adult↗

Method for optimizing the correction of the eye's higher-order aberrations in the presence of decentrations.

The use of a correcting element to compensate for higher-order aberrations in an optical system often requires accurate alignment of the correcting element. This is not always possible, as in the case of a contact lens on the eye. We propose a method consisting of partial correction of every aberration term to minimize the average variance of the residual wave-front aberration produced by Gaussian decentrations (translations and rotations). Analytical expressions to estimate the fraction of every aberration term that should be corrected for a given amount of decentration are derived. To demonstrate the application of this method, three examples are used to compare performance with total and with partial correction. The partial correction is more robust and always yields some benefit regardless of the amount of decentration.

Humans↗

Contribution of the cornea and internal surfaces to the change of ocular aberrations with age.

We studied the age dependence of the relative contributions of the aberrations of the cornea and the internal ocular surfaces to the total aberrations of the eye. We measured the wave-front aberration of the eye with a Hartmann-Shack sensor and the aberrations of the anterior corneal surface from the elevation data provided by a corneal topography system. The aberrations of the internal surfaces were obtained by direct subtraction of the ocular and corneal wave-front data. Measurements were obtained for normal healthy subjects with ages ranging from 20 to 70 years. The magnitude of the RMS wave-front aberration (excluding defocus and astigmatism) of the eye increases more than threefold within the age range considered. However, the aberrations of the anterior corneal surface increase only slightly with age. In most of the younger subjects, total ocular aberrations are lower than corneal aberrations, while in the older subjects the reverse condition occurs. Astigmatism, coma, and spherical aberration of the cornea are larger than in the complete eye in younger subjects, whereas the contrary is true for the older subjects. The internal ocular surfaces compensate, at least in part, for the aberrations associated with the cornea in most younger subjects, but this compensation is not present in the older subjects. These results suggest that the degradation of the ocular optics with age can be explained largely by the loss of the balance between the aberrations of the corneal and the internal surfaces.

Adult↗

Calculated impact of higher-order monochromatic aberrations on retinal image quality in a population of human eyes.

We calculated the impact of higher-order aberrations on retinal image quality and the magnitude of the visual benefit expected from their correction in a large population of human eyes. Wave aberrations for both eyes of 109 normal subjects and 4 keratoconic patients were measured for 3-, 4-, and 5.7-mm pupils with a Shack-Hartmann sensor. Retinal image quality was estimated by means of the modulation transfer function (MTF) in white light. The visual benefit was calculated as the ratio of the MTF when the monochromatic higher-order aberrations are corrected to the MTF corresponding to the best correction of defocus and astigmatism. On average, the impact of the higher-order aberrations for a 5.7-mm pupil in normal eyes is similar to an equivalent defocus of approximately 0.3 D. The average visual benefit for normal eyes at 16 c/deg is approximately 2.5 for a 5.7-mm pupil and is negligible for small pupils (1.25 for a 3-mm pupil). The benefit varies greatly among eyes, with some normal eyes showing almost no benefit and others a benefit higher than 4 at 16 c/deg across a 5.7-mm pupil. The benefit for keratoconic eyes is much larger. The benefit at 16 c/deg is 12 and 3 for 5.7- and 3-mm pupils, respectively, averaged across four keratoconics. These theoretical benefits could be realized in normal viewing conditions but only under specific conditions.

Adult↗

Peripheral refractive errors in myopic, emmetropic, and hyperopic young subjects.

To gain more insight into the relationship between foveal and peripheral refractive errors in humans, spheres, cylinders, and their axes were binocularly measured across the visual field in myopic, emmetropic, and hyperopic groups of young subjects. Both automated infrared photorefraction (the "PowerRefractor"; www. plusoptix.de) and a double-pass technique were used because the PowerRefractor provided extensive data from the central 44 deg of the visual field in a very convenient and fast way. Two-dimensional maps for the average cross cylinders and spherical equivalents, as well as for the axes of the power meridians of the cylinders, were created. A small amount of lower-field myopia was detected with a significant vertical gradient in spherical equivalents. In the central visual field there was little difference among the three refractive groups. The established double-pass technique provided complementary data also from the far periphery. At 45 deg eccentricity the double-pass technique revealed relatively more hyperopic spherical equivalents in myopic subjects than in emmetropic subjects [+/-2.73 +/- 2.85 D relative to the fovea, p < 0.01 (+/- standard deviation)] and more myopic spherical equivalents in hyperopic subjects (-3.84 +/- 2.86 D relative to the fovea, p < 0.01). Owing to the pronounced peripheral astigmatism, spherical equivalents (refractions with respect to the plane of the circle of least confusion) became myopic relative to the fovea in all three groups. The finding of general peripheral myopia was unexpected. Its possible roles in foveal refractive development are discussed.

Adult↗

Effect of beam size on the expected benefit of customized laser refractive surgery.

PURPOSE: Customized laser surgery attempts to correct higher order aberrations, as well as defocus and astigmatism. The success of such a procedure depends on using a laser beam that is small enough to produce fine ablation profiles needed to correct higher order aberrations. METHODS: Wave aberrations were obtained from a population of 109 normal eyes and 4 keratoconic eyes using a Shack-Hartmann wavefront sensor. We considered a theoretical customized ablation in each eye, performed with beams of 0.5, 1.0, 1.5, and 2.0 mm in diameter. We then calculated the residual aberrations remaining in the eye for the different beam sizes. Retinal image quality was estimated by means of the modulation transfer function (MTF), computed from the residual aberrations. Fourier analysis was used to study spatial filtering of each beam size. RESULTS: The laser beam acts like a spatial filter, smoothing the finest features in the ablation profile. The quality of the correction declines steadily when the beam size increases. A beam of 2 mm is capable of correcting defocus and astigmatism. Beam diameters of 1 mm or less may effectively correct aberrations up to fifth order. CONCLUSION: Large diameter laser beams decrease the ability to correct higher order aberrations. A top-hat laser beam of 1 mm (Gaussian with FWHM of 0.76 mm) is small enough to produce a customized ablation for typical human eyes.

Adult↗

Theoretical elastic response of the cornea to refractive surgery: risk factors for keratectasia.

PURPOSE: To explore the role that mechanical elastic factors may have in post-refractive surgery corneal phenomena, from mild curvature changes to keratectasia. METHODS: The central cornea near the apex was modeled as an elastic spherical thin shell loaded by the intraocular pressure (IOP). Equations for myopic laser in situ keratomileusis (LASIK) were obtained to estimate shifts and curvature changes of the posterior corneal surface at the apex. The effect of every parameter was studied, identifying potential risk factors for ectasia. RESULTS: Theoretically, corneal thinning by ablation will produce an elastic deformation of the posterior surface that depends on the corneal parameters (curvature, Young's modulus, Poisson ratio, and thickness), the IOP, and the ablation profile. In particular, a forward shift and an increase in power of the posterior surface was predicted for myopic LASIK, in agreement with previous experimental findings. These changes rise non-linearly with the attempted correction, and are greater for thinner preoperative corneas, higher IOP smaller Young's modulus, and thicker flaps. Corneas with Young's modulus half the average or less, or thickness <500 microm, may present high risk of ectasia, especially for high IOP and thick flaps. CONCLUSIONS: Some postoperative effects may be explained in part by elasticity. Research efforts are needed to explain other biomechanical behaviors. The accepted criterion of 250 microm residual bed is insufficient for fine patient screening--depending on the individual ocular parameters, it could be more restrictive. Advances in technology are needed to create a preoperative examination including two-dimensional maps of topography, pachymetry, and Young's modulus.

Cornea↗