Integrating polymerase chain reaction, valving, and electrophoresis in a plastic device for bacterial detection.

An integrated plastic microfluidic device was designed and fabricated for bacterial detection and identification. The device, made from poly(cyclic olefin) with integrated graphite ink electrodes and photopatterned gel domains, accomplishes DNA amplification, microfluidic valving, sample injection, on-column labeling, and separation. Polymerase chain reaction (PCR) is conducted in a channel reactor containing a volume as small as 29 nL; thermal cycling utilizes screen-printed graphite ink resistors. In situ gel polymerization was employed to form local microfluidic valves that minimize convective flow of the PCR mixture into other regions. After PCR, amplicons (products) are electrokinetically injected through the gel valve, followed by on-chip electrophoretic separation. An intercalating dye is admixed to label the amplicons; they are detected using laser-induced fluorescence. Two model bacteria, Escherichia coli O157 and Salmonella typhimurium, were chosen to demonstrate bacterial detection and identification based on amplification of several of their unique DNA sequences. The limit of detection is about six copies of target DNA.

Bacteria↗

Use of floating electrodes in transient isotachophoresis to increase the sensitivity of detection.

We report a protocol for on-chip electrophoretic sample loading and sample component separation in which each operation requires simultaneous control of the potential of only two electrodes: during the sample-loading phase, the potentials at the ends of the separation channel are electrically floating; during electrophoresis of the sample mixture down the separation channel, the potentials at the ends of the sample-introduction channel are floating. This method, which we call "floating-stacking," avoids the dispersion/distortion of the sample plug that is commonly associated with simultaneous electrical control of only two electrodes in a crossed-channel or offset-double-tee injection system. Further, when this floating loading/separation is done in the presence of back-transient-isotachophoresis, sample loss from the plug of material being injected is minimal and a significant concentration increase--up to 13x--of the sample components in the separated bands occurs relative to the commonly used "pinch-and-pull-back" technique (which requires simultaneous electrical control of four electrodes).

CSK Tyrosine-Protein Kinase↗

Miniaturized capillary isoelectric focusing in plastic microfluidic devices.

We report the demonstration of miniaturized capillary isoelectric focusing (CIEF) in plastic microfluidic devices. Conventional CIEF technique was adapted to the microfluidic devices to separate proteins and to detect protein-protein interactions. Both acidic and basic proteins with isoelectric points (pI) ranging from 5.4 to 11.0 were rapidly focused, mobilized, and detected in a 1.2 cm long channel (50 microm deep x 120 microm wide) with a total analysis time of 150 s. In a device with a focusing distance of 4.7 cm, the separation efficiency for a basic protein, lysozyme, was achieved as high as 1.5 x 10(5) plates, corresponding to 3.2 million plates per meter. We also experimentally confirmed that IEF resolution is essentially independent of focusing length when the applied voltage is kept the same and within a range that it does not cause Joule heating. Further, we demonstrated the use of miniaturized CIEF to study the interactions between two pairs of proteins, immunoglobulin G (IgG) with protein G and anti-six histidine (anti-6xHis) with 6xHis-tagged green fluorescent protein (GFP). Using this approach, protein-protein interactions can be detected for as little as 50 fmol of protein. We believe miniaturized CIEF is useful for studying protein-protein interactions when there is a difference in pI between a protein-protein complex and its constitutent proteins.