PubMed Health⌕ Search

Biomedical subjects

Antonius A C M Kalker

Publications and source records attributed to Antonius A C M Kalker.

2 recordsLinked to original sources

Cardiac image segmentation for contrast agent videodensitometry.

Indicator dilution techniques are widely used in the intensive care unit and operating room for cardiac parameter measurements. However, the invasiveness of current techniques represents a limitation for their clinical use. The development of stable ultrasound contrast agents allows new applications of the indicator dilution method. Ultrasound contrast agent dilutions permit an echographic noninvasive measurement of cardiac output, ejection fraction, and blood volumes. The indicator dilution curves are measured by videodensitometry of specific regions of interest and processed for the cardiac parameter assessment. Therefore, the major indicator dilution imaging issue is the detection of proper contrast videodensitometry regions that maximize the signal-to-noise ratio of the measured indicator dilution curves. This paper presents an automatic contour detection algorithm for indicator dilution videodensitometry. The algorithm consists of a radial filter combined with an outlier correction. It maximizes the region of interest by excluding cardiac structures that act as interference to the videodensitometric analysis. It is fast, projection independent, and allows the simultaneous detection of multiple contours in real time. The system is compared to manual contour definition on both echographic and magnetic resonance images.

Algorithms↗

Identification of ultrasound contrast agent dilution systems for ejection fraction measurements.

Left ventricular ejection fraction is an important cardiac-efficiency measure. Standard estimations are based on geometric analysis and modeling; they require time and experienced cardiologists. Alternative methods make use of indicator dilutions, but they are invasive due to the need for catheterization. This study presents a new minimally invasive indicator dilution technique for ejection fraction quantification. It is based on a peripheral injection of an ultrasound contrast agent bolus. Left atrium and left ventricle acoustic intensities are recorded versus time by transthoracic echocardiography. The measured curves are corrected for attenuation distortion and processed by an adaptive Wiener deconvolution algorithm for the estimation of the left ventricle impulse response, which is interpolated by a monocompartment exponential model for the ejection fraction assessment. This technique measures forward ejection fraction, which excludes regurgitant volumes. The feasibility of the method was tested on a group of 20 patients with left ventricular ejection fractions going from 10% to 70%. The results are promising and show a 0.93 correlation coefficient with echographic bi-plane ejection fraction measurements. A more extensive validation as well as an investigation on the method applicability for valve insufficiency and right ventricular ejection fraction quantification will be an object of future study.

Algorithms↗