A direct antigen heterologous enzyme immunoassay for measuring progesterone in serum without using displacer.

An antigen heterologous enzyme-linked immunosorbent assay (ELISA) for directly measuring progesterone in serum is described. Six combinations of antigens and enzyme conjugates were tested; the enzyme conjugate 17-alphaOH-progesterone-3-O-carboxymethyloxime-alkalinephosphatase (17-alphaOH-P-3-CMO-ALP) and the immunogen progesterone-3-carboxymethyloxime-bovine serum albumin (P-3-CMO-BSA) were found to be best. Fifty microliters of standard or serum sample and 100 microL of the 17-alphaOH-P-3-CMO-ALP enzyme conjugate were added to the antibody coated wells, and incubated for 1 h at 37 degrees C. Bound enzyme activity was measured by using p-nitrophenyl phosphate as substrate. The sensitivity of the assay was 0.11 ng/mL, and intra- and inter-assay CVs ranged from 5.1% to 9.6%. The analytical recoveries were 97-105%. The serum progesterone values obtained by this method correlated well with those obtained by radioimmunoassay; r=0.97 (n=44). Moreover, in this ELISA no displacing agent was used or special means was required to displace progesterone from corticosteroid binding globulin (CBG). Serum progesterone concentrations of subjects, with histories of recurrent spontaneous abortions were also measured, and correlated well with clinical history.

17-alpha-Hydroxyprogesterone↗

The influence of spacer-containing enzyme conjugate on the sensitivity and specificity of enzyme immunoassays for hapten.

BACKGROUND: In hapten enzyme immunoassays (EIA), there is an increase or decrease of labeled hapten recognition by antibody that affects sensitivity of the assay. We incorporated a spacer between a hapten derivative and enzyme to test its influence on the sensitivity and specificity of enzyme immunoassays. METHOD: Antibodies were generated against cortisol-3-O-carboxymethyl-oxime-bovine serum albumin (cortisol-3-O-CMO-BSA) and cortisol-21-hemisuccinate-bovine serum albumin (cortisol-21-HS-BSA) as an immunogen. Four cortisol horseradish peroxidase (HRP) enzyme conjugates were prepared using 2 cortisol derivatives (cortisol-3-O-CMO and cortisol-21-HS) with and without adipic acid dihydrazide (ADH) as a spacer. Eight combinations of homologous and heterologous assays were evaluated. RESULT: The incorporation of ADH spacer in cortisol-enzyme conjugate improved the sensitivity in heterologous (bridge and site plus bridge) EIA systems. In heterologous assays (site plus bridge), the presence of spacer in enzyme conjugate reduced the cross-reactivity with cross-reacting steroids. CONCLUSION: Spacer in the enzyme conjugate for hapten ELISA can improve the sensitivity of heterologous assay of hapten-like steroids. It may also reduce the cross-reactivity for some assays.

Adipates↗

Development of isotopic and non-isotopic microwell based immunoassays for hCG using 125I and biotin labeled hCG.

Isotopic and non-isotopic immunoassays of hCG, based on the principle of competitive inhibition, using micro-well as solid support and 125I and biotin as labels for hCG, have been developed. In both the assays, rabbit polyclonal antibody was immobilized onto micro-wells. In the non-isotopic assay, to the hCG antibody coated micro-wells, 50 microL of standard or samples along with 100 microL of biotinylated hCG were incubated for 1 hour at 37 degrees C. After incubation, wells were washed and 100 microL of streptavidin-HRP conjugate was added to each well and incubated again for a half hour at 37 degrees C. Bound enzyme activity was measured using tertramethyl benzidine/hydrogen peroxide (TMB/H2O2) as substrate. In the isotopic assay, to the hCG antibody coated micro-wells, 50 microL of standard or samples along with 100 microL of 125I-hCG were incubated for 1 hour at 37 degrees C. The bound radioactivity was measured using a gamma counter. The sensitivities of the non-isotopic and isotopic assays were 0.12 IU/mL and 0.1 IU/mL, respectively. The intra- and inter-assay CVs for both the assays were less than 12.3%. There was a good correlation between the developed non-isotopic and isotopic immunoassays (r = 0.97, n = 20).

Animals↗

Your diagnosis? Scaphoid fracture.

Fractures of the scaphoid are the most common carpal bone fracture. With careful management, prognosis is excellent. Imaging is critical, not only for early diagnosis, but also for monitoring patients after initial treatment to detect unstable fractures, the common complications of nonunion and avascular necrosis, and the need for surgical treatment.

Adult↗

Coordinated problem solving through resource sharing in a distributed environment.

An important feature in a distributed problem solving system is that the resources of different nodes can be shared through cooperation. In this paper, the generalized partial global planning (GPGP) approach used for multiagent systems is extended by providing a coordination mechanism for resource sharing across nodes. In our framework, multiple conflicting criteria (or objectives) like quality, cost, and duration may be associated with an input task. Preference ratings expressed subjectively may be assigned to each of the criteria. Task assignment in this system, which is a multiobjective decision making problem, is important for the satisfaction of the criteria. It has to be done with imprecise information since the system is dynamic and preference ratings are specified subjectively. A technique for task assignment using the fuzzy set approach is also presented in this paper. Simulation studies for the coordination mechanism and the task assignment have been performed to demonstrate their effectiveness.

Letter↗

Substitution of carbonate buffer by water for IgG immobilization in enzyme linked immunosorbent assay.

The first step of enzyme linked immunosorbent assay (ELISA), namely, adsorption of antigen or antibody to the plastic microtiter well plate, was studied as a function of insolubility of IgG in water. Immobilization efficiency was assessed in terms of number of wells coated per milliliter of primary antiserum. We have compared different coating/immobilization protocols, i.e., direct and indirect immobilization of primary antibody to the plastic microtiter well plate using carbonate buffer and phosphate buffer with glutaraldehyde. We have observed efficient coating when the immobilization of primary antibody through an immunobridge technique was performed, where water was used as a coating medium. It gave a higher number of wells coated per milliliter of anti-serum (primary or secondary) than other compared coating protocols and it allowed the use of serum (non-immune) and anti-serum (primary and secondary antibody) dilutions, avoiding the need for gamma-globulin purification from normal and immunized serum.

Adipates↗

One step enzyme linked immunosorbent assay for direct estimation of serum testosterone.

One step competitive enzyme linked immunosorbent assay (ELISA) for direct estimation of testosterone in human serum is described. Testosterone-3-O-carboxymethyl-oxime-bovine serum albumin (testosterone-3-O-CMO-BSA), was used as immunogen and testosterone-3-O-carboxymethyl-oxime-adipic-acid dihydrazide-horseradish peroxidase (testosterone-3-O-CMO-ADH-HRP) was used as tracer. To the testosterone antibody coated microtiter wells, standard or serum samples (100 microL), along with testosterone-3-O-CMO-ADH-HRP conjugate (100 microL) were incubated for 1 h at 37 degrees C. Bound enzyme activity was measured by using tetra methyl benzidine/hydrogen peroxide (TMB/H2O2) as a substrate. In this new strategy, charcoal stripped pooled human serum spiked with non-cross reactive C18, C19, C21, and C27 steroids, used for preparing the standards and blocking the sex hormone binding globulin (SHBG)/and other steroid binding globulins (SBG). The sensitivity of the assay was 0.015 ng/mL. The intra-assay and inter-assay coefficients of variation (CVs) were ranged from 7.8 to 11.8 and 4.8 to 10.4, respectively. The serum testosterone values, obtained by this method, were correlated well with those obtained by radioimmunoassay r = .98 (n = 100).

Adipates↗