PubMed Health⌕ Search

Biomedical subjects

Arben Merkoçi

Publications and source records attributed to Arben Merkoçi.

8 recordsLinked to original sources

Electrochemical biosensing with nanoparticles.

This minireview looks at the latest trends in the use of nanoparticles (NPs) in electrochemical biosensing systems. It includes electrochemical characterization of NPs for use as labels in affinity biosensors and other applications. DNA analysis involving NPs is one of the most important topics of current research in bionanotechnology. The advantages of the use of NPs in designing novel electrochemical sensors for DNA analysis are reviewed. Electrochemical NPs can also be used in designing immunoassays, offering the possibility of easy, low cost and simultaneous detection of several proteins. Research into NP applications in electrochemical analysis is in its infancy. Several aspects related to sensitivity as well integration of all the assay steps into a single one need to be improved.

Animals↗

Graphite epoxy composite electrodes modified with bacterial cells.

The modification of a graphite-epoxy composite electrode (GECE) with bacterial cells along with an analytical application are presented. Pseudomonas putida DSM 50026 was used as a biological component and the measurement was based on the respiratory activity of the cells. The optimization of working conditions of resulting biosensor (including pH and temperature) was conducted and the limit of detection was calculated as 7 microM phenol based on the signal to noise ratio. Then the system was applied for xenobiotic detection. Resulting sample signals were found to be very similar with the standard solutions having the same concentration while the recoveries of the spiked samples were close to 100%.

Biosensing Techniques↗

Microchip electrophoresis with wall-jet electrochemical detector: influence of detection potential upon resolution of solutes.

This report studies the electrochemical response of wall-jet detector for microchip electrophoresis (microCE). It shows that in wall-jet configuration, the electrochemical detector operates in coulometric mode and that there is an influence of detection potential upon peak width and therefore upon the resolution of solutes. Upon raising the detection potential from +0.3 to +0.9 V, the resolution between model analytes, dopamine and catechol, increases from 0.63 to 2.90. The reasons for this behavior originate in wall-jet detector design and in its typically significant higher detector volume than the volume of injected sample. The conversion efficiency of the wall-jet electrochemical detection cell was found to be 97.4% for dopamine and 98.0% for catechol. The paper brings deeper understanding of operations of wall-jet electrochemical detectors for microchip devices, and it explains previously reported significantly sharper peaks when electrocatalytic electrodes (i.e., palladium and carbon nanotube) were used in microCE-electrochemistry wall-jet detector.

Catechols↗

Magnetically trigged direct electrochemical detection of DNA hybridization using Au67 quantum dot as electrical tracer.

A novel gold nanoparticle-based protocol for detection of DNA hybridization based on a magnetically trigged direct electrochemical detection of gold quantum dot tracers is described. It relies on binding target DNA (here called DNA1) with Au(67) quantum dot in a ratio 1:1, followed by a genomagnetic hybridization assay between Au(67)-DNA1 and complementary probe DNA (here called DNA2) marked paramagnetic beads. Differential pulse voltammetry is used for a direct voltammetric detection of resulting Au(67) quantum dot-DNA1/DNA2-paramagnetic bead conjugate on magnetic graphite-epoxy composite electrode. The characterization, optimization, and advantages of the direct electrochemical detection assay for target DNA are demonstrated. The two main highlights of presented assay are (1) the direct voltammetric detection of metal quantum dots obviates their chemical dissolution and (2) the Au(67) quantum dot-DNA1/DNA2-paramagnetic bead conjugate does not create the interconnected three-dimensional network of Au-DNA duplex-paramagnetic beads as previously developed nanoparticle DNA assays, pushing down the achievable detection limits.

DNA↗

Toward an ICPMS-linked DNA assay based on gold nanoparticles immunoconnected through peptide sequences.

Gold nanoparticles modified with anti-mouse IgG have been used to trace oligonucleotides carrying a c-myc peptide. Two strategies, a dot-blot format as well as inductively coupled plasma mass spectrometry (ICPMS) have been used to detect the nanoparticle tracer. For both cases, oligonucleotide-peptide conjugates were first applied to a nitrocellulose membrane using a manifold attached to a suction device. After immobilization of the oligonucleotide by UV radiation, the samples were incubated with an anti-c-myc monoclonal antibody. In the case of the dot-blot format strategy, it was followed by incubation with a secondary antibody conjugated to horseradish peroxidase and development with luminol as chemiluminescent substrate. In the case of ICPMS strategy, it was followed by incubation with the secondary antibody (anti-mouse IgG) conjugated to gold nanoparticles and their ICPMS detection after dissolving. The nonspecific adsorptions were found to be around zero. The limit of detection for peptide-modified DNA was 0.2 pmol. The method may have significant potential as an important ICPMS-based nonradioactive DNA detection method for the simultaneous determination of various sequences by labeling different kinds of inorganic nanoparticles.

DNA↗

Glucose biosensor based on carbon nanotube epoxy composites.

A novel glucose biosensor based on a rigid and renewable carbon nanotube (CNT) based biocomposite is reported. The biosensor was based on the immobilization of glucose oxidase (GOx) within the CNT epoxy-composite matrix prepared by dispersion of multi-wall CNT inside the epoxy resin. The use of CNT, as the conductive part of the composite, ensures better incorporation of enzyme into the epoxy matrix and faster electron transfer rates between the enzyme and the transducer. Experimental results show that the CNT epoxy composite biosensor (GOx-CNTEC) offers an excellent sensitivity, reliable calibration profile, and stable electrochemical properties together with significantly lower detection potential (+0.55 V) than GOx-graphite epoxy composites (+0.90 V; difference deltaE = 0.35 V). The results obtained favorably compare to those of a glucose biosensor based on a graphite epoxy composite (GOx-GEC).

Biosensing Techniques↗

Graphite-epoxy composites as a new transducing material for electrochemical genosensing.

The use of a rigid carbon-polymer composite material as an electrochemical transducer in hybridisation genosensors is reported. Graphite-epoxy composites (GEC) have an uneven surface where DNA can be adsorbed using a simple dry-adsorption procedure. Single-stranded-DNA binds strongly to GEC in a way that prevents the strands from self-associating, while permitting hybridisation with complementary DNA. Hybridisation has been detected through biotin-streptavidin interaction using a streptavidin conjugated to horseradish peroxidase. Non-specific adsorption onto GEC is almost non-existent even when the surface has not been treated by blocking reagents. The analytical signal obtained was higher when compared with other electrochemical genosensors. Results can be achieved in 150 min, and the detection limit is in the order of fmol. Additionally, surface regeneration is possible using a simple polishing procedure, allowing for multiple use. The new genosensor based on GEC fulfils the requirements desired for these devices: ease of preparation as dry-adsorption of DNA is very simple and easily automated, robustness, sensitivity, low cost of production, ease of miniaturisation and simple use and fast response. Additionally, it can be used for field measurements and can be produced as a genosensor kit. Also, this material can be implemented for screen-printing procedures for the mass production of genosensors. The utility of the genosensor based on GEC is also illustrated with the detection of a sequence related to novel determinant of beta-lactamase resistance in Staphylococcus aureus.

Adsorption↗

Electrochemical coding technology for simultaneous detection of multiple DNA targets.

Nucleic-acid hybridization assays based on the use of different inorganic-colloid (quantum dots) nanocrystal tracers for the simultaneous electrochemical measurements of multiple DNA targets are described. Three encoding nanoparticles (zinc sulfide, cadmium sulfide, and lead sulfide) are used to differentiate the signals of three DNA targets in connection to stripping-voltammetric measurements of the heavy metal dissolution products. These products yield well-defined and resolved stripping peaks at -1.12 V (Zn), -0.68 V (Cd), and -0.53 V (Pb) at the mercury-coated glassy-carbon electrode (vs Ag/AgCl reference). The position and size of these peaks reflect the identity and level of the corresponding DNA target. The multi-target detection capability is coupled to the amplification feature of stripping voltammetry (to yield femtomole detection limits) and with an efficient magnetic removal of nonhybridized nucleic acids to offer high sensitivity and selectivity. The protocol is illustrated for the simultaneous detection of three DNA sequences related to the BCRA1 breast-cancer gene in a single sample in connection to magnetic beads bearing the corresponding oligonucleotide probes. The new electrochemical coding is expected to bring new capabilities for DNA diagnostics, and for bioanalysis, in general.

Breast Neoplasms↗