PubMed Health⌕ Search

Biomedical subjects

Ardawan Rastan

Publications and source records attributed to Ardawan Rastan.

9 recordsLinked to original sources

Replacing cardiopulmonary bypass with extracorporeal membrane oxygenation in lung transplantation operations.

OBJECTIVE: Cardiopulmonary bypass (CPB) support is required in some lung transplantation (LTX) operations. CPB support and full-dose heparin increases the risks of bleeding and early graft dysfunction. We report our experiences of replacing CPB with heparin-bonded low-dose heparin extracorporeal membrane oxygenation (ECMO) support in LTX surgery. METHODS: From 2003 to 2005 forty-seven patients were transplanted. Thirty-seven LTX patients were retrospectively evaluated for this study (10 patients were excluded due to heart-lung-, lung-kidney transplantation, LTX with bypass grafting, and ASD closure or emergency CPB support). Extracorporeal circulation support was necessary in 40% of the 37 LTX patients due to severe primary or secondary pulmonary hypertension (P or SPHTN), right heart dysfunction, or hemodynamic instability. There were seven LTX procedures with CPB and eight implantations with ECMO support. CPB (high-dose heparin) and ECMO support (ACT 160-220 s) was always set up through femoral veno-arterial canulation. All patients had limited access thoracotomies without transsection of the sternum. Normothermia was maintained in all patients. CPB patients: PPH 15%, COPD 15%, IPF with mean PAP>40 mmHg 70%. ECMO patients: PPH 13%, COPD 13%, IPF with severe PAP pressure elevation 74%. RESULTS: In patients undergoing LTX for PPH, the ECMO support was directly extended into the post-operative period. Packed red blood cell (PRBC) transfusion requirements during the operation and the first 24h were 13.25+/-1.6 PRBC units versus 5.1+/-2.8 PRBC units on CBP (p=0.02). Operative time was longer (p=0.11) in the ECMO LTX (451 min+/-76 vs 346+/-140). The increased 90-day mortality rate of the ECMO patients showed a trend toward significance (p=0.056), which was related to infectious complications (3 vs 1 patient). Severe graft ischemia/reperfusion injury occurred in 9% in the CPB versus 13% in the ECMO group. The 1-year survival was significantly reduced in ECMO patients (p=0.004, log-rank test). CONCLUSIONS: The advantages of femoral canulation rather than conventional central connections in lung transplantation procedures led to an undisturbed operative field. A significantly higher blood product amount was required in ECMO patients, which might lead to increased infection and mortality rates. CPB, obviously, should remain the standard support technique if extracorporeal circulation is required in lung transplantation surgery.

Adult↗

Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement.

OBJECTIVE: The aim of this study was to evaluate the impact of patient prosthesis mismatch (PPM) and additional risk factors on outcome after aortic valve replacement (AVR). METHODS: Four thousand one hundred and thirty-one patients who were operated between May 1996 and April 2004 were evaluated. One thousand eight hundred and fifty-six patients received bileaflet mechanical AVR and 2275 stented xenograft AVR. PPM was defined as severe if manufacturers effective orifice area (EOA) divided by body surface area (BSA) was <0.65 cm(2)/m(2) and as moderate in the range of 0.65-0.85 cm(2)/m(2). PPM, age, gender, EOA index, emergency indication for surgery (within 24h), EuroSCORE as well as requirement for additional procedures were tested. Univariate (Fisher's exact test) and multivariate logistic regression analysis as well as survival analysis (Kaplan-Meier) were performed. RESULTS: Severe PPM was present in 97 (2.4%) and moderate PPM in 1103 (26.7%) patients. PPM occurs more frequently with xenograft AVR. In-hospital mortality was 5.2% for severe, 10.6% for moderate and 6.9% with no PPM (p=0.018, OR 1.4). Moderate PPM was independently predictive for short- and long-term mortality. Further analysis revealed patient age >70 years (n=1589, p=0.002, OR 1.85), emergency indication (n=374, p<0.001, OR 4.4), EuroSCORE >10 (n=494, p<0.001, OR 4.7) and additional cardiac procedures (n=2049, p<0.001, OR 2.0) as predictors for adverse outcome after AVR. CONCLUSION: Severe PPM is rare; moderate PPM is present in a quarter of patients. PPM has a significant impact on short- and long-term mortality after AVR.

Aged↗

Reverse remodeling of cardiac collagen protein expression after surgical therapy for experimental aortic stenosis.

BACKGROUND AND AIM OF THE STUDY: Reversal of myocardial collagen gene expression was examined in parallel to left ventricular reverse remodeling after surgical correction of experimental aortic stenosis. METHODS: A standard growing sheep model (age at baseline 6-8 months) was used. Measurements were performed at baseline (point A) when inducing left ventricular hypertrophy (LVH) through supracoronary banding, at 8.3 +/- 1.0 months later at surgical correction (point B), and after another 10.1 +/- 2.0 months during final examinations (point C). Gene expression for collagen I and III was also studied. RESULTS: Left ventricular function was stable throughout the study. The left ventricular mass index (LVMI) was 82 +/- 21 g/m2 at point A, 150 +/- 33 g/m2 at B, and 78 +/- 18 g/m2 at C (p <0.01). Myocardial fiber diameter was 11.3 +/- 0.8, 15.9 +/- 1.2 and 11.4 +/- 1 microm at points A, B and C, respectively (p <0.01). Protein expression for collagen I was 0.71 +/- 0.2 (at A), 1.13 +/- 0.3 (at B) and 0.85 +/- 0.4 (at C) (p <0.01), while that for collagen III was 0.72 +/- 0.4 (at A), 1.26 +/- 0.8 (at B) and 0.83 +/- 0.3 (at C) (p <0.01). There was a significant correlation between changes in LVMI and myocardial collagen expression. CONCLUSION: Complete reverse remodeling with regression of LVH and myocardial collagen protein expression can be anticipated after surgical correction of experimental aortic stenosis.

Animals↗

Clinical experience with stentless mitral valve replacement.

BACKGROUND: Our aim is to describe the clinical experience with stentless mitral valve (SMV) replacement with special focus on the functionality of the SMV. METHODS: Fifty-two patients (68 +/- 8.5 years old; 36 female) have been prospectively evaluated since August 1997. The chordally supported SMV (Quattro) was implanted for mitral stenosis (n = 26), severe incompetence (n = 17), or mixed lesion (n = 9). Preoperative New York Heart Association class was 3.1 +/- 0.6. Twenty patients received additional intraoperative ablation therapy. Mean follow-up is 37.3 +/- 18.7 months (range, 1 to 65). RESULTS: Surgery was performed using conventional sternotomy (33) or anterolateral minithoracotomy (19). Atrial rhythm was reestablished in 17 of 20 patients. Six patients operated on early in this series required reoperation, 2 for paravalvular leakage, 2 for functional stenosis, 1 with pannus formation due to underlying rheumatoid disease, and 1 for papillary flap rupture after 5.1 years. Mortality was 1 perioperative (1.9%, nonvalve related) and 1 after reoperation due to multiorgan failure. During late follow-up (30 +/- 7 months postoperatively) 5 patients died of noncardiac causes. Regular echocardiographic control revealed good SMV function (maximum transmitral blood flow velocity 1.7 +/- 0.2 m/s; mean transmitral pressure gradient 3.9 +/- 1.2 mm Hg) and well-preserved ejection fraction postoperatively as well as at most recent follow-up. CONCLUSIONS: The clinical experience after 5.5 years of SMV implantation is promising. Preservation of annuloventricular continuity is advantageous. However, long-term durability remains to be proved.

Aged↗

A novel adhesion barrier facilitates reoperations in complex congenital cardiac surgery.

OBJECTIVE: Reoperations are associated with an increased surgical risk due to adhesions. We prospectively evaluated a bioresorbable membrane after surgery for congenital heart defects over a 3.5-year period. METHODS: The surgical membrane (CV Seprafilm, Genzyme, Cambridge, Mass) was applied in 350 of 1024 patients; 30 of them underwent reoperation and were evaluated in comparison to 10 random reoperated patients. Adhesions were evaluated using a subjective scoring system [1 (lowest tenacity) to 5 (highest tenacity)] and extent in percent at different regions of the heart. RESULTS: Patients were operated for atrioventricular septal defect (69), tetralogy of Fallot (65), functional single ventricle (75), valve surgery (48), ventricular septal defect (20), subaortic stenosis (17), hypoplastic left heart syndrome (17), and other diagnoses (39). Application of the surgical membrane was safe in all patients, without any infections. At reoperation patients received Glenn (14), total cavopulmonary connection (6), and others (10). Overall mortality was 2/350 (0.57%). There was a remarkable reduction in tenacity score (3.3 vs 4.3) and in the extent of adhesions (77.7% vs 86%). Duration of reoperation was significantly reduced. CONCLUSIONS: A bioresorbable surgical membrane leads to a significant reduction in the tenacity and amount of adhesions. It is recommended for general use whenever repeat operation is anticipated in congenital as well as in adult cardiac surgery.

Aortic Valve Stenosis↗

Prospectively randomized evaluation of stented xenograft hemodynamic function in the aortic position.

BACKGROUND: Standard stented aortic xenograft valves have not yet been compared regarding their hemodynamic function using a stratified intraoperative randomization protocol. METHODS AND RESULTS: 100 patients were prospectively included after intraoperative metric sizing of the decalcified aortic annulus. They received Mosaic (M) or Perimount (P) aortic valve replacement. Patient age was 73+/-5 years, 51 were female, and New York Heart Association (NYHA) functional class was 2.8+/-0.5. The 21-mm annulus group consisted of 5 (M)/7 (P) patients, the 23-mm annulus group of 20 (M)/20 (P), the 25-mm annulus group of 18 (M)/19 (P), and the 27-mm annulus group of 4 (M)/7 (P) patients, respectively. Hemodynamic function was evaluated using transthoracic echocardiography before discharge and at follow-up (438+/-352 days). Surgery was uncomplicated in all patients. Labeled valve sizes were 0.93 (M) and 1.05 (P) mm smaller than the annulus diameters (p=NS). In-hospital mortality was 5%, all nonvalve-related. Transvalvular blood flow velocities and transvalvular pressure gradients were significantly lower in the 25 P versus the 25 M group at baseline and in the 23 P and 25 P groups at follow-up. There was a significant regression of left ventricular mass index in all patients at follow-up. However, left ventricular mass regression was more pronounced after P aortic valve replacement. CONCLUSIONS: Labeled sizes of prosthetic heart valves implanted are smaller than the true aortic annulus. Both standard aortic xenografts compared in this prospectively randomized trial provide a sufficient hemodynamic and functional outcome.

Aged↗

Primary repair for aortic arch obstruction associated with ventricular septal defect.

BACKGROUND: The aim of the present study was to evaluate the current outcome and reoperation rate after applying a one-stage correction strategy for interrupted aortic arch (IAA) with ventricular septal defect (VSD) and also for aortic coarctation and hypoplastic aortic arch (CoA-HyAA) with VSD beginning September 1999. METHODS: Twenty-four consecutive patients with IAA (n = 12) or CoA-HyAA (n = 12) with VSD underwent early one-stage correction. Patients' mean age was 12 days (range, 2 to 188); mean weight was 3.6 kg (range, 2.1 to 7.3), 6 patients were less than 2.5 kg. Three IAA were type A, 5 type B1, 3 type B2, and 1 type C. Associated anomalies included a large VSD in all, left ventricular outlet tract obstruction in 5, transposition of the great arteries, aortopulmonary window, persistent truncus arteriosus, and double-outlet right ventricle in 1 patient. Selective brain perfusion through innominate artery and selective coronary perfusion through aortic root during aortic arch reconstruction was used in all patients. Mean follow-up was 2.2 +/- 0.9 years. RESULTS: There was no early, no late mortality, and no postoperative neurologic complications. Mean crossclamp duration was 72 +/- 32 minutes, lowest temperature 22.8 +/- 4 degrees C and selective brain and coronary perfusion duration was 34 +/- 13 minutes. Eighteen patients required delayed sternal closure at 1.7 days postoperatively. New perioperative management reduced the overall morbidity. Four patients after IAA plus VSD repair developed aortic arch restenosis and were successfully treated by balloon dilatation. One patient with d-TGA underwent right ventricular outflow tract reconstruction of right ventricular outlet tract obstruction 7 months after the initial repair. Pressure gradients across the anastomosis at most recent follow up were less than 10 mm Hg. All patients are asymptomatic and are developing normally. CONCLUSIONS: One-stage complete correction is feasible in newborns with aortic arch obstruction with VSD. Complex cardiac anatomy presents no additional risk for the procedure. The early one-stage correction yields excellent surgical results and good functional outcome.

Aorta, Thoracic↗

Midterm results after stentless mitral valve replacement.

BACKGROUND: To analyze the midterm clinical results after stentless mitral valve (SMV) replacement. METHODS AND RESULTS: Fifty one patients (68.3+/-8.4 years, 35 female) with severe mitral valve disease (stenosis 25, incompetence 17, mixed lesion 9) received a chordally supported SMV (Quattro, St. Jude Medical Inc.) since August 1997. Preoperative New York Heart Association class was 3.1+/-0.6; left ventricular ejection fraction 64+/-13%, and cardiac index 2.1+/-0.8 l/min/m2. Additional intraoperative ablation therapy was performed on 19 patients with chronic atrial fibrillation. Mean follow-up is 35.4+/-19.2 months (range 5 to 63). SMV implantation was performed using a conventional (32) or a minimally invasive (19) approach, valve size was 29+/-1.5 mm, cross-clamp duration was 81+/-33 minutes. Atrial rhythm was reestablished in 16 of 19 patients. Five patients required reoperation early in this series, two for paravalvular leakage, two for functional stenosis, and one with underlying rheumatoid disease. Mortality was one perioperative (1.96%, non-valve-related), one after reoperation as a result of multiple organ failure (MOF), and five during late follow-up (30+/-7 months postoperatively) for noncardiac causes. Regular echocardiographic control revealed good SMV function (Vmax 1.7+/-0.2m/s, P(mean) 3.9+/-1.2 mm Hg) and well-preserved ejection fraction postoperatively and at most recent follow-up. CONCLUSIONS: Midterm results after SMV implantation are promising. Preservation of the annuloventricular continuity leads to stable left ventricular function and combined with ablation therapy to physiological hemodynamics. Long-term durability remains to be proven.

Aged↗

Ultrastructural alterations in acquired aortic and mitral valve disease as revealed by scanning and transmission electron microscopical investigations.

Scanning and transmission electron microscopical investigations were carried out on explanted human aortic and mitral valves to study the prevalence of hyperplastic and degenerative lesions in acquired valvular dysfunction. Biopsies were taken from 67 aortic and 23 mitral valves. All of the valves examined showed degenerative lesions including a loose binding of the endothelial cells, a partial denudation of the endothelial cover and areas of fibrous hyperplasia surrounded by calcium deposits. Additionally, the formation of various excrescences was detected by means of scanning electron microscopy. Of all excrescences identified, 90% were localized at the free margin of the leaflet, 3% in the subnodular region and 7% in the nodule of Arantius. The ratio of filiform to lamellar forms of hyperplastic lesions was approximately 80% in most of the samples examined. The results presented demonstrate the complex ultrastructural features of surgically explanted human valves showing both degenerative and hyperplastic lesions in the same valve.

Aged↗