Comparison between different sheathless electrospray emitter configurations regarding the performance of nanoscale liquid chromatography-time-of-flight mass spectrometry analysis.

Four different sheathless electrospray ionization (ESI) configurations were investigated for a nano liquid chromatography (LC) system. The studied configurations were: a column with an integrated emitter, with the ESI potential applied before or after the column, and a column with separate emitter, with the ESI voltage applied at a union before the emitter or at the emitter tip. The results indicates that the efficiency of the LC system is rather independent of the configuration when using 95 microm i.d. columns, acetic mobile phase and standard peptides as a sample. Introduction of post column dead volume seems not to be a critical issue at least with flow rates down to 600 nl/min.

Nanotechnology↗

A feasibility study of solid supported enhanced microdialysis.

For the first time, a solid supported enhanced microdialysis methodology for analysis of neuropeptides is described. The microdialysis samples were, in this study, subsequently collected in fractions, dissolved from the solid particles, dried, and resolved in a formic acid buffer in order to make them suitable for capillary liquid chromatography-mass spectrometry. Different microdialysis flow profiles were evaluated where air-gapped continuous flow was considered most suitable for the solid supported microdialysis mode. Six endogenous neuropeptides were initially used to investigate the feasibility of this enhanced microdialysis methodology. The improved relative recovery obtained from the solid supported enhanced microdialysis was varying from no effect to 10 times higher as compared to ordinary microdialysis. The most efficient enrichment was obtained for luteinizing hormone releasing hormone, which was the largest but also the most hydrophilic of the peptides. In contrast, no significant difference in recovery was observed for Leu-enkephalin being the smallest and the most hydrophobic peptide tested. These results indicate an increased flux and selective uptake of hydrophilic peptides across the membrane and enrichment on the particles in solid supported microdialysis.

Chromatography, High Pressure Liquid↗

Interference of the electrospray voltage on chromatographic separations using porous graphitic carbon columns.

The electrospray ionization (ESI) voltage is shown to interfere with liquid chromatographic separations performed with packed porous graphitic carbon (PGC) capillary columns. This interference is ascribed to the presence of an electric field over the conductive column in the absence of an earth point between the column and the ESI emitter. The current evolved alters the chromatographic behavior of the catecholamine metabolite 3-O-methyl-DOPA significantly, as both peak splitting and a dramatic decrease in the retention time were observed. Furthermore, the response from the mass spectrometer was decreased by 33% at the same time. A related compound, tyrosine, exhibited decreased retention times but no peak splitting, whereas no shifts in the retention times (or peak splitting) were seen for the less retained dopamine and noradrenaline. When the current through the PGC column was eliminated by the use of an earth point between the column and the ESI emitter, the chromatographic behavior of the column was found to return slowly to normal after hours of equilibration with 60 : 40 (v/v) methanol-ammonium formate buffer of pH 2.9. The behavior of the PGC column with and without the earth point was found to be highly reproducible during a period of 1 month. We propose that the effect of the ESI voltage on the chromatographic behavior of the PGC column is due to associated redox reactions affecting both the PGC particles and the analytes. It is concluded that (for analytical reasons), care should be taken to ensure that no current is flowing through the chromatographic system when interfacing PGC columns, and conducting parts in general, to ESI mass spectrometry.

Chromatography, Liquid↗

Gold-coated fused-silica sheathless electrospray emitters based on vapor-deposited titanium adhesion layers.

Gold-coated fused-silica electrospray (ES) emitters based on vapor-deposited adhesion layers of titanium have been manufactured to investigate the possibilities of producing durable ES emitters applicable in chip-based analytical devices. The stabilities of the emitters were studied by both electrospray and electrochemical experiments and a marked increase in the emitter lifetime, compared to that for Cr/Au coated emitters, was found for the Ti/Au emitters in the ES durability tests. This indicates that Ti (rather than Cr) adhesion layers should be used in association with large-scale fabrication of ES emitters by vapor-deposition techniques. The lifetime of about 500-700 hours also allowed the Ti/Au-coated emitter to be used as an integrated part of a capillary liquid chromatography column coupled to a mass spectrometer in a series of LC/MS experiments. The Ti/Au coating was further studied by electrochemical techniques and scanning electron microscopy in conjunction with X-ray spectroscopy. It is shown that the eventual failure of the Ti/Au emitters in ES experiments was due to an almost complete detachment of the gold layer. Experimental evidence suggests that the detachment of the gold coating was due to a reduced adhesion to the titanium layer during oxidation in positive electrospray. Most likely, this was caused by the formation of an oxide layer on the titanium film. It is thus shown that unlimited emitter stabilities are not automatically obtained even if the metallic adhesion layer is stabilized by an oxide formation under positive electrospray conditions.

Journal Article↗

Quantitation of tryptophan, kynurenine and kynurenic acid in human plasma by capillary liquid chromatography-electrospray ionization tandem mass spectrometry.

Concentrations of tryptophan and its metabolites in plasma are of great interest in determining proper diagnosis and medication of several neurological diseases like, for example, Alzheimer's disease. A method of standard addition was developed to determine total level of tryptophan and two of its metabolites, kynurenine and kynurenic acid, in human plasma by capillary liquid chromatography-electrospray ionization tandem mass spectrometry. Plasma samples were simply deproteinized by addition of diluted perchloric acid. Samples were then mixed with trichloroacetic acid and injected onto a capillary column. Analytes were separated by a fast gradient elution of the injected samples. Detection was performed by sheathless electrospray tandem mass spectrometry in the multiple reaction monitoring mode. Linear calibration curves were obtained for spiked plasma sample with up to 100% of the expected analytes concentrations. The determined concentrations were well within ranges previously reported (i.e., 6 nM-95 microM) and limit of detections were around 3 nM for each analyte.

Calibration↗