Compensation for spin-lock artifacts using an off-resonance rotary echo in T1rhooff-weighted imaging.

The origin of image artifacts in an off-resonance spin-locking experiment is shown to be imperfections in the excitation flip angle. A pulse sequence for off-resonance spin locking is implemented that compensates for imperfections in the excitation flip angle through an off-resonance rotary echo. The off-resonance rotary echo alternates the frequency offset and phase of the RF transmitter during two spin-locking pulses of equal duration. The underlying theory is detailed, and MR images demonstrate the effectiveness of the technique in agarose gel phantoms and in in vivo human brain at 3T.

Algorithms↗

Assessment of human disc degeneration and proteoglycan content using T1rho-weighted magnetic resonance imaging.

STUDY DESIGN: T1rho relaxation was quantified and correlated with intervertebral disc degeneration and proteoglycan content in cadaveric human lumbar spine tissue. OBJECTIVE: To show the use of T1rho-weighted magnetic resonance imaging (MRI) for the assessment of degeneration and proteoglycan content in the human intervertebral disc. SUMMARY OF BACKGROUND DATA: Loss of proteoglycan in the nucleus pulposus occurs during early degeneration. Conventional MRI techniques cannot detect these early changes in the extracellular matrix content of the disc. T1rho MRI is sensitive to changes in proteoglycan content of articular cartilage and may, therefore, be sensitive to proteoglycan content in the intervertebral disc. METHODS: Intact human cadaveric lumbar spines were imaged on a clinical MR scanner. Average T1rho in the nucleus pulposus was calculated from quantitative T1rho maps. After MRI, the spines were dissected, and proteoglycan content of the nucleus pulposus was measured. Finally, the stage of degeneration was graded using conventional T2 images. RESULTS: T1rho decreased linearly with increasing degeneration (r = -0.76, P < 0.01) and age (r = -0.76, P < 0.01). Biochemical analysis revealed a strong linear correlation between T1rho and sulfated-glycosaminoglycan content. T1rho was moderately correlated with water content. CONCLUSIONS: Results from this study suggest that T1rho may provide a tool for the diagnosis of early degenerative changes in the disc. T1rho-weighted MRI is a noninvasive technique that may provide higher dynamic range than T2 and does not require a high static field or exogenous contrast agents.

Adolescent↗

In vivo quantification of human lumbar disc degeneration using T(1rho)-weighted magnetic resonance imaging.

Diagnostic methods and biomarkers of early disc degeneration are needed as emerging treatment technologies develop (e.g., nucleus replacement, total disc arthroplasty, cell therapy, growth factor therapy) to serve as an alternative to lumbar spine fusion in treatment of low back pain. We have recently demonstrated in cadaveric human discs an MR imaging and analysis technique, spin-lock T(1rho)-weighted MRI, which may provide a quantitative, objective, and non-invasive assessment of disc degeneration. The goal of the present study was to assess the feasibility of using T(1rho) MRI in vivo to detect intervertebral disc degeneration. We evaluated ten asymptomatic 40-60-year-old subjects. Each subject was imaged on a 1.5 T whole-body clinical MR scanner. Mean T(1rho) values from a circular region of interest in the center of the nucleus pulposus were calculated from maps generated from a series of T(1rho)-weighted images. The degenerative grade of each lumbar disc was assessed from conventional T(2)-weighted images according to the Pfirmann classification system. The T(1rho) relaxation correlated significantly with disc degeneration (r=-0.51, P<0.01) and the values were consistent with our previous cadaveric study, in which we demonstrated correlation between T(1rho) and proteoglycan content. The technique allows for spatial measurements on a continuous rather than an integer-based scale, minimizes the potential for observer bias, has a greater dynamic range than T(2)-weighted imaging, and can be implemented on a 1.5 T clinical scanner without significant hardware modifications. Thus, there is a strong potential to use T(1rho) in vivo as a non-invasive biomarker of proteoglycan loss and early disc degeneration.

Adult↗

A pulse sequence for rapid in vivo spin-locked MRI.

PURPOSE: To develop a novel pulse sequence called spin-locked echo planar imaging (EPI), or (SLEPI), to perform rapid T1rho-weighted MRI. MATERIALS AND METHODS: SLEPI images were used to calculate T1rho maps in two healthy volunteers imaged on a 1.5-T Sonata Siemens MRI scanner. The head and extremity coils were used for imaging the brain and blood in the popliteal artery, respectively. RESULTS: SLEPI-measured T1rho was 83 msec and 103 msec in white (WM) and gray matter (GM), respectively, 584 msec in cerebrospinal fluid (CSF), and was similar to values obtained with the less time-efficient sequence based on a turbo spin-echo readout. T1rho was 183 msec in arterial blood at a spin-lock (SL) amplitude of 500 Hz. CONCLUSION: We demonstrate the feasibility of the SLEPI pulse sequence to perform rapid T1rho MRI. The sequence produced images of higher quality than a gradient-echo EPI sequence for the same contrast evolution times. We also discuss applications and limitations of the pulse sequence.

Brain Mapping↗

In vivo measurement of plaque burden in a mouse model of Alzheimer's disease.

PURPOSE: To demonstrate an MRI method for directly visualizing amyloid-beta (Abeta) plaques in the APP/PS1 transgenic (tg) mouse brain in vivo, and show that T1rho relaxation rate increases progressively with Alzheimer's disease (AD)-related pathology in the tg mouse brain. MATERIALS AND METHODS: We obtained in vivo MR images of a mouse model of AD (APP/PS1) that overexpresses human amyloid precursor protein, and measured T1rho via quantitative relaxometric maps. RESULTS: A significant decrease in T1rho was observed in the cortex and hippocampus of 12- and 18-month-old animals compared to their age-matched controls. There was also a correlation between changes in T1rho and the age of the animals. CONCLUSION: T1rho relaxometry may be a sensitive method for noninvasively determining AD-related pathology in APP/PS1 mice.

Alzheimer Disease↗

Sodium and T1rho MRI for molecular and diagnostic imaging of articular cartilage.

In this article, both sodium magnetic resonance (MR) and T1rho relaxation mapping aimed at measuring molecular changes in cartilage for the diagnostic imaging of osteoarthritis are reviewed. First, an introduction to structure of cartilage, its degeneration in osteoarthritis (OA) and an outline of diagnostic imaging methods in quantifying molecular changes and early diagnostic aspects of cartilage degeneration are described. The sodium MRI section begins with a brief overview of the theory of sodium NMR of biological tissues and is followed by a section on multiple quantum filters that can be used to quantify both bi-exponential relaxation and residual quadrupolar interaction. Specifically, (i) the rationale behind the use of sodium MRI in quantifying proteoglycan (PG) changes, (ii) validation studies using biochemical assays, (iii) studies on human OA specimens, (iv) results on animal models and (v) clinical imaging protocols are reviewed. Results demonstrating the feasibility of quantifying PG in OA patients and comparison with that in healthy subjects are also presented. The section concludes with the discussion of advantages and potential issues with sodium MRI and the impact of new technological advancements (e.g. ultra-high field scanners and parallel imaging methods). In the theory section on T1rho, a brief description of (i) principles of measuring T1rho relaxation, (ii) pulse sequences for computing T1rho relaxation maps, (iii) issues regarding radio frequency power deposition, (iv) mechanisms that contribute to T1rho in biological tissues and (v) effects of exchange and dipolar interaction on T1rho dispersion are discussed. Correlation of T1rho relaxation rate with macromolecular content and biomechanical properties in cartilage specimens subjected to trypsin and cytokine-induced glycosaminoglycan depletion and validation against biochemical assay and histopathology are presented. Experimental T1rho data from osteoarthritic specimens, animal models, healthy human subjects and as well from osteoarthritic patients are provided. The current status of T1rho relaxation mapping of cartilage and future directions is also discussed.

Animals↗

T1rho contrast in functional magnetic resonance imaging.

The application of T1 in the rotating frame (T1rho) to functional MRI in humans was studied at 3 T. Increases in neural activity increased parenchymal T1rho. Modeling suggested that cerebral blood volume mediated this increase. A pulse sequence named spin-locked echo planar imaging (SLEPI) that produces both T1rho and T2* contrast was developed and used in a visual functional MRI (fMRI)experiment. Spin-locked contrast significantly augments the T2* blood oxygen level-dependent (BOLD) contrast in this sequence. The total functional contrast generated by the SLEPI sequence (1.31%) was 54% larger than the contrast (0.85%) obtained from a conventional gradient-echo EPI sequence using echo times of 30 ms. Analysis of image SNR revealed that the spin-locked preparation period of the sequence produced negligible signal loss from static dephasing effects. The SLEPI sequence appears to be an attractive alternative to conventional BOLD fMRI, particularly when long echo times are undesirable, such as when studying prefrontal cortex or ventral regions, where static susceptibility gradients often degrade T2*-weighted images.

Algorithms↗

Detection of changes in articular cartilage proteoglycan by T(1rho) magnetic resonance imaging.

The purpose of this work is to demonstrate the feasibility of T(1rho)-weighted magnetic resonance imaging (MRI) to quantitatively measure changes in proteoglycan content in cartilage. The T(1rho) MRI technique was implemented in an in vivo porcine animal model with rapidly induced cytokine-mediated cartilage degeneration. Six pigs were given an intra-articular injection of recombinant porcine interleukin-1beta (IL-1beta) into the knee joint before imaging to induce changes in cartilage via matrix metalloproteinase (MMP) induction. The induction of MMPs by IL-1 was used since it has been extensively studied in many systems and is known to create conditions that mimic in part characteristics similar to those of osteoarthritis. The contralateral knee joint was given a saline injection to serve as an internal control. T(1rho)-weighted MRI was performed on a 4 T whole-body clinical scanner employing a 2D fast spin-echo-based T(1rho) imaging sequence. T(1rho) relaxation parameter maps were computed from the T(1rho)-weighted image series. The average T(1rho) relaxation rate, R(1rho) (1/T(1rho)) of the IL-1beta-treated patellae was measured to be on average 25% lower than that of saline-injected patellae indicating a loss of proteoglycan. There was an average reduction of 49% in fixed charge density, measured via sodium MRI, of the IL-1beta-treated patellae relative to control corroborating the loss of proteoglycan. The effects of IL-1beta, primarily loss of PG, were confirmed by histological and immunochemical findings. The results from this study demonstrate that R(1rho) is able to track proteoglycan content in vivo.

Animals↗

In vivo measurement of T1rho dispersion in the human brain at 1.5 tesla.

PURPOSE: To measure T1rho relaxation times and T1rho dispersion in the human brain in vivo. MATERIALS AND METHODS: Magnetic resonance imaging (MRI) was performed on a 1.5-T GE Signa clinical scanner using the standard GE head coil. A fast spin-echo (FSE)-based T1rho-weighted MR pulse sequence was employed to obtain images from five healthy male volunteers. Optimal imaging parameters were determined while considering both the objective of the study and the guarantee that radio-frequency (RF) power deposition during MR did not exceed Food and Drug Administration (FDA)-mandated safety levels. RESULTS: T1rho-weighted MR images showed excellent contrast between different brain tissues. These images were less blurred than corresponding T2-weighted images obtained with similar contrast, especially in regions between brain parenchyma and cerebrospinal fluid (CSF). Average T1rho values for white matter (WM), gray matter (GM), and CSF were 85 +/- 3, 99 +/- 1, and 637 +/- 78 msec, respectively, at a spin-locking field of 500 Hz. T1rho is 30% higher in the parenchyma and 78% higher in CSF compared to the corresponding T2 values. T1rho dispersion was observed between spin-locking frequencies 0 and 500 Hz. CONCLUSION: T1rho-weighted MRI provides images of the brain with superb contrast and detail. T1rho values measured in the different brain tissues will serve as useful baseline values for analysis of T1rho changes associated with pathology.

Adult↗

Correlation of T1rho with fixed charge density in cartilage.

PURPOSE: To establish the specificity of T1rho with respect to fixed charge density (FCD) as a measure of proteoglycan (PG) content in cartilage during the onset of osteoarthritis (OA). MATERIALS AND METHODS: T1rho-weighted and sodium MRI were performed on cartilage samples of enzymatically degraded bovine explants and natural osteoarthritic human samples representing controlled and physiological models of OA, respectively. Spatial maps of T1rho and FCD (measured using the previously validated method of sodium MRI) were calculated from image data. Data were extracted from the maps and subjected to linear regression to compare changes in T1rho with changes in FCD in each model. Tissue samples were subjected to histological staining for a reduction in PG content. RESULTS: Plots of normalized T1rho rate vs. FCD were found to be strongly correlated (R2 > 0.75 and 0.85) in both models with nearly the same slope of approximately 1/2 (P > 0.51). Loss of PG in bovine and human tissue was confirmed by histology. CONCLUSION: The strong correlation of the FCD and T1rho data in both the controlled and physiological models demonstrates that changes in T1rho are due predominantly to changes in PG content. This work is a first step in establishing T1rho as a method of quantifying PG changes in early-stage OA.

Animals↗

Pulse sequence for multislice T1rho-weighted MRI.

A 2D multislice spin-lock (MS-SL) MR pulse sequence is presented for rapid volumetric T1rho-weighted imaging. Image quality is compared with T1rho-weighted data collected using a single-slice (SS) SL sequence and T2-weighted data from a standard MS spin-echo (SE) sequence. Saturation of longitudinal magnetization by the application of nonselective SL pulses is experimentally measured and theoretically modeled as T2rho decay. The saturation data is used to correct the image data as a function of the SL pulse duration to make quantitative measurements of T1rho. Measurements of T1rho using the saturation-corrected MS-SL data are nearly identical to those measured using an SS-SL sequence. The MS-SL sequence produces quantitative T1rho maps of an entire sample volume with the high-SNR advantages conferred by SE-based sequences.

Animals↗

Method for reduced SAR T1rho-weighted MRI.

A reduced specific absorption rate (SAR) version of the T(1rho)-weighted MR pulse sequence was designed and implemented. The reduced SAR method employs a partial k-space acquisition approach in which a full power spin-lock pulse is applied to only the central phase-encode lines of k-space, while the remainder of k-space receives a low-power spin-lock pulse. Acquisition of high- and low-power phase-encode lines are interspersed chronologically to minimize average power deposition. In this way, the majority of signal energy in the central portion of k-space receives full T(1rho)-weighting, while the average SAR of the overall acquisition can be reduced, thereby lowering the minimum safely allowable TR. The pulse sequence was used to create T(1rho) maps of a phantom, an in vivo mouse brain, and the brain of a human volunteer. In the images of the human brain, SAR was reduced by 40% while the measurements of T(1rho) differed by only 2%. The reduced SAR sequence enables T(1rho)-weighted MRI in a clinical setting, even at high field strengths.

Animals↗

Reduction of residual dipolar interaction in cartilage by spin-lock technique.

The influence of radiofrequency (RF) spin-lock pulse on the laminar appearance of articular cartilage in MR images was investigated. Spin-lock MRI experiments were performed on bovine cartilage plugs on a 4.7 Tesla small-bore MRI scanner, and on human knee cartilage in vivo on a 1.5 Tesla clinical scanner. When the normal to the surface of cartilage was parallel to B0, a typical laminar appearance was exhibited in T2-weighted images of cartilage plugs, but was absent in T1rho-weighted images of the same plugs. At the "magic angle" orientation (when the normal to the surface of cartilage was 54.7 degrees with respect to B0), neither the T2 nor the T1rho images demonstrated laminae. At the same time, T1rho values were greater than T2 at both orientations throughout the cartilage. T1rho dispersion (i.e., the dependence of the relaxation rate on the spin-lock frequency omega1) was observed, which reached a steady-state value of close to 2 kHz in both parallel and magic-angle orientations. These results suggest that residual dipolar interaction from motionally-restricted water and relaxation processes, such as chemical exchange, contribute to T1rho dispersion in cartilage. Further, one can reduce the laminar appearance in human articular cartilage by applying spin-lock RF pulses, which may lead to a more accurate diagnosis of degenerative changes in cartilage.

Animals↗

In vivo quantification of T1rho using a multislice spin-lock pulse sequence.

A multislice spin-lock (MS-SL) pulse sequence is implemented on a clinical scanner to acquire multiple images with spin-lock-generated contrast of the knee joints of six healthy human subjects. The MS-SL sequence produces images with T1rho contrast with an additional factor of intrinsic T2rho weighting, which hinders direct measurement of T1rho. A method is presented to compensate the MS-SL-generated data with regard to T2rho in an effort to accurately calculate multislice T1rho maps in a feasible experimental time. The T2rho-compensated multislice T1rho maps produced errors in the measurement of T1rho in healthy patellar cartilage of approximately 5% compared to the gold standard measurement of T1rho acquired with single-slice spin-lock pulse sequence. The MS-SL sequence has potential as an important clinical tool for the acquisition of multislice T1rho-weighted images and/or quantitative multislice T1rho maps.

Adult↗

T2rho-weighted contrast in MR images of the human brain.

In this work, the feasibility of using T2rho weighting as an MR contrast mechanism is evaluated. Axial images of a human brain were acquired using a single-slice spin-lock T2rho-weighted pulse sequence and compared to analogous T2-weighted images of the same slice. The contrast between white matter and gray matter in T2rho-weighted images was approximately 40% greater than that from T2-weighted data. These preliminary data suggest that the novel contrast mechanism of T2rho can be used to yield high-contrast T2-like images.

Adult↗

3D-T1rho-relaxation mapping of articular cartilage: in vivo assessment of early degenerative changes in symptomatic osteoarthritic subjects.

RATIONALE AND OBJECTIVES: To determine the in vivo feasibility of quantifying early degenerative changes in patellofemoral joint of symptomatic human knee using spin-lattice relaxation time in the rotating frame (T(1rho)) magnetic resonance imaging (MRI). MATERIALS AND METHODS: All the MRI experiments were performed on a 1.5 T whole-body GE Signa clinical scanner using a custom built 15-cm diameter transmit-receive quadrature birdcage radiofrequency coil. The T(1rho)-prepared magnetization was imaged with a three-dimensional gradient-echo pulse sequence pre-encoded with a three-pulse cluster consisting of two hard 90 degrees pulses and a low power spin-lock pulse. Quantitative T(1rho) relaxation maps of asymptomatic (n = 8 males), and six symptomatic human volunteers (four men, two women) were computed using a appropriate signal expression. RESULTS: All six symptomatic volunteers showed elevation in T(1rho) relaxation times when compared with asymptomatic subjects. In symptomatic population, the T(1rho) relaxation times varied from 63 +/- 4 ms to 95 +/- 12 ms (mean +/- standard deviation) depending on the degree of cartilage degeneration. The increase in T(1rho) of symptomatic population was statistically significant (n = 6, P <.002) when compared with corresponding asymptomatic population. However, in asymptomatic population the relaxation times varied only from approximately 45 to 55 ms (n = 8, age range 22-45 years). CONCLUSION: Preliminary results demonstrated the in vivo feasibility of quantifying early biochemical changes in symptomatic osteoarthritis subjects employing T(1rho)-weighted MRI on a 1.5 T clinical scanner. This study on limited number of symptomatic population shows that T(1rho)-weighted MRI provides a noninvasive marker for quantitation of early degenerative changes of cartilage in vivo. However, further studies are needed to correlate early osteoarthritis determined from arthroscopy with T(1rho) in a large symptomatic population.

Adult↗

Cartilage volume quantification via Live Wire segmentation.

RATIONALE AND OBJECTIVES: A reduction in cartilage volume is characteristic of osteoarthritis and hence there exists a need for an accurate and reproducible method to measure in vivo cartilage volume. Quantification of cartilage volume from magnetic resonance (MR) images requires a segmentation technique such as the user-driven "Live Wire" strategy that can reliably delineate object volumes in a time-efficient manner. In the present work, the accuracy and reproducibility of the Live Wire method for the quantification of cartilage volume in MR images is evaluated. MATERIALS AND METHODS: The accuracy of the Live Wire method was assessed by comparing the MR-based volume measurement of a patellar cartilage-shaped phantom versus data calculated via water displacement. The inter- and intra-operator reproducibility of the technique was evaluated from Live Wire segmentation of the patellar cartilage volume from fat-suppressed 3-dimensional spoiled-gradient-echo images of five healthy human volunteers performed by three operators. To provide data for analysis of inter-scan reproducibility, the human scans were repeated five times with the aid of a leg-restraining jig to minimize repositioning error. RESULTS: The volume of the patellar cartilage-shaped phantom measured via Live Wire segmentation of MR images was within 97.8% of its true volume. The average inter- and intra-operator coefficients of variation of three operators were 3.0% and 0.4%, respectively. The average inter-scan coefficient of variation of five repeated scans of each volunteer was 2.7%. CONCLUSION: The data suggest that the Live Wire strategy is an accurate, reproducible, and efficient technique to measure cartilage volume in vivo in a feasible amount of operator time.

Adult↗

T1rho-weighted MRI using a surface coil to transmit spin-lock pulses.

T1rho-weighted MRI is a novel basis for generating tissue contrast. However, it suffers from sensitivity to B1 inhomogeneity. First, excitation with a spatially varying B1 causes flip-angle artifacts and second, spin locking with an inhomogeneous B1 results in non-uniform T1rho contrast. In this study, we overcome the former complication with a specially designed spin-locking pulse sequence and we successfully obtain T1rho-weighted images with a surface coil. In this pulse sequence, the spin-lock pulse was divided into segments of equal duration and alternating phase. This "self-compensating" T1rho-preparatory pulse sequence was analyzed and the effect of an inhomogeneous B1 field was simulated using the Bloch equations. T1rho-weighted MR images of a phantom and a human knee joint in vivo were obtained on a clinical scanner with a surface coil to demonstrate the utility of the pulse sequence. The self-compensating T1rho-prepared pulses sequence resulted in substantially reduced image artifacts compared to the conventional, single-phase spin-lock pulse.

Adult↗