PubMed Health⌕ Search

Biomedical subjects

Armando Manduca

Publications and source records attributed to Armando Manduca.

15 recordsLinked to original sources

Development of a cathartic-free colorectal cancer screening test using virtual colonoscopy: a feasibility study.

OBJECTIVE: The purpose of our study was to develop a method to subtract barium-labeled stool from the colon using a phantom and to evaluate the performance of the technique in a pilot human population. MATERIALS AND METHODS: A phantom containing 6-mm flat polyps and three types of simulated stool (homogeneous, moderately heterogeneous, and severely heterogeneous) mixed with barium was created, scanned, and tested using three stool subtraction algorithms but no cathartic. Thirty patients with suspected colorectal polyps were studied using stool tagging to determine which was the most effective stool subtraction algorithm. Colonoscopy was the reference standard. Examinations were evaluated blindly using the unsubtracted and 6 weeks later both the unsubtracted and subtracted data sets. RESULTS: A threshold of 200 H and expansion and convolution techniques were the most effective tools for subtracting stool and minimizing artifacts. When applied to the human population, sensitivities using the unsubtracted data sets were 90% (18/20) and 68% (26/38) for polyps > or = 1 cm and > or = 5 mm, respectively. Specificities were 100% (4/4) and 75% (3/4) for polyps > or = 1 cm and > or = 5 mm. For the stool-subtracted data sets, sensitivities were 90% (18/20) and 71% (27/38) for polyps > or = 1 cm and > or = 5 mm. Per patient sensitivities were 88% (15/17) and 77% (20/26) for > or = 1 cm and > or = 5 mm polyps. Specificities were 100% (4/4) for large polyps and 25% (1/4) for smaller polyps. CONCLUSION: Image processing tools combining thresholding, expansion, and convolution were the most useful for stool subtraction. Laxative-free colon examinations using barium for stool labeling can be performed at CT colonography with or without stool subtraction with high accuracy. Further study is warranted.

Algorithms↗

Stiffness-weighted magnetic resonance imaging.

An imaging method is introduced in which the signal in MR images is affected by the stiffness distribution in the object being imaged. Intravoxel phase dispersion (IVPD) that occurs during MR elastography (MRE) acquisitions decreases the signal in soft regions more than in stiff regions due to changes in shear wave amplitude and wavelength. The IVPD effect is enhanced by lowpass filtering the MR k-space data with a circular Gaussian lowpass filter. A processing method is introduced to take the time series of MRE magnitude images with IVPD and produce a final stiffness-weighted image (SWI) by calculating the minimum signal at each pixel from a small number of temporal samples. The SWI technique is demonstrated in phantom studies as well as in the case of a preserved postmortem breast tissue specimen with a stiff lesion created by focused ultrasound ablation to mimic a breast cancer. When free of significant sources of depth-dependent wave attenuation, interference, and boundary effects, SWI is a simple, fast, qualitative technique that does not require the use of phase unwrapping or inversion algorithms for localizing stiff regions in an object.

Algorithms↗

Differential effects of pre-tension on shear wave propagation in elastic media with different boundary conditions as measured by magnetic resonance elastography and finite element modeling.

Magnetic resonance elastography (MRE) can non-invasively determine material stiffness based on the propagating shear wavelength. Shear wave propagation in a finite homogenous isotropic material can be affected by multiple factors. In this study we examined the effects of pre-tension and frequency on MRE shear measurements of gel phantoms with different boundary conditions, frequencies, and geometries. Results from MRE measurements were compared to wave motion theory in elastic solids and qualitatively to a finite element (FE) model. Results indicated that boundary conditions, geometry and pre-tension are important factors to be considered when performing MRE tests on a finite material, and that FE modeling can help explore how the shear wave propagation is affected under various boundary conditions and axial stresses, among other potential factors.

Biocompatible Materials↗

Mechanical transient-based magnetic resonance elastography.

Magnetic resonance elastography (MRE) is a technique for quantifying material properties by measuring cyclic displacements of propagating shear waves. As an alternative to dynamic harmonic wave MRE or quasi-steady-state methods, the idea of using a transient impulse for mechanical excitation is introduced. Two processing methods to calculate shear stiffness from transient data were developed. The techniques were tested in phantom studies, and the transient results were found to be comparable to the harmonic wave results. Transient wave based analysis was applied to the brains of six healthy volunteers in order to assess the method in areas of complex wave patterns and geometry. The results demonstrated the feasibility of measuring brain stiffness in vivo using a transient mechanical excitation. Transient and harmonic methods both measure white matter (approximately 12 kPa) to be stiffer than gray matter ( approximately 8 kPa). There were some anatomic differences between harmonic and transient MRE, specifically where the transient results better depicted the deeper structures of the brain.

Algorithms↗

Quantitative shear wave magnetic resonance elastography: comparison to a dynamic shear material test.

Magnetic resonance elastography (MRE), a phase contrast MRI technique, images the propagation of applied mechanical waves in tissue, allowing shear stiffness to be quantified in vivo. This MRE technique has been validated with static mechanical compression tests. Dynamic mechanical analysis (DMA) may be a more appropriate comparison to MRE because it directly measures the shear modulus dynamically, while compression tests convert the measured elastic modulus to shear modulus with an assumed Poisson ratio. This study compared the shear stiffness estimated with various MRE inversion algorithms (i.e., manual calculation, local frequency estimate, phase gradient, direct inversion, and matched filter) to the dynamic mechanical test. The shear stiffness of five agarose gels with concentrations ranging from 1.5 to 3.5% were measured using MRE and DMA. The phase gradient inversion algorithm overestimated the shear modulus at higher concentrations (i.e., 3-3.5% agar), while the results from the other techniques correlated well with the dynamic mechanical test.

Agar↗

Examination of dosimetry accuracy as a function of seed detection rate in permanent prostate brachytherapy.

The variation of permanent prostate brachytherapy dosimetry as a function of seed detection rates was investigated for I125 implants with seed activities commonly employed in contemporary practice. Post-implant imaging and radiation dosimetry data from nine patients who underwent PPB served as the basis of this simulation study. One-thousand random configurations of detected seeds were generated for each patient dataset using various seed detection levels from 30% to 99%. Dose parameters, including D90, were computed for each configuration and compared with the actual dosimetry data. A total of 108 000 complete sets of post-PPB dose volume statistics were computed. The results demonstrated that although the average D90 differed from the true value by less than 5% when 70% or more seeds were identified, the D90 of an individual case could deviate up to 13%. The 95% confidence interval (CI) of estimated D90 values differ by less than 5% from the actual value when 95% or more seeds are detected, or approximately a 7 Gy difference in the D90 value for a prescription dose of 144 Gy. Estimated target volume dose parameters tended to decrease with reduced seed detection rates. The most variable dose parameter was the prostate V100 in absolute scale while the urethral V100 was most variable in a relative sense. Based on this comprehensive simulation study, it is suggested that 95% or more seeds need to be localized in order to provide an accurate estimation of dose parameters for contemporary iodine 125 permanent prostate brachytherapy.

Brachytherapy↗

A finite element model for analyzing shear wave propagation observed in magnetic resonance elastography.

Magnetic resonance elastography (MRE) is a novel non-invasive approach to determine material stiffness by using a conventional magnetic resonance imaging (MRI) system incorporated with an oscillating motion-sensitizing gradient to detect nodal displacements produced by a shear excitation wave. The effects of material properties, excitation frequency, boundary conditions, and applied tension on shear wavelength measurement must be examined before MRE can become a useful diagnostic tool. We propose finite element (FE) modeling as a robust method to systematically study the effects of these parameters. An axisymmetric FE model was generated with ABAQUS to simulate agarose gel phantoms. The effects of material stiffness, density, and excitation frequency on propagating shear wavelength were examined individually. The effect of the boundary conditions on shear wavelength was also demonstrated. Results of shear wavelength from MRE measurement were compared with the results of FE model, which showed good agreement between the methods.

Biomechanical Phenomena↗

Self-navigated motion correction using moments of spatial projections in radial MRI.

Interest in radial MRI (also known as projection reconstruction (PR) MRI) has increased recently for uses such as fast scanning and undersampled acquisitions. Additionally, PR acquisitions offer intrinsic advantages over standard two-dimensional Fourier transform (2DFT) imaging with respect to motion of the imaged object. It is well known that aligning each spatial domain projection's center of mass (calculated using the 0th and 1st moments) to the center of the field of view (FOV) corrects shifts caused by in-plane translation. In this work, a previously unrealized ability to determine the in-plane rotational motion of an imaged object using the 2nd moments of the spatial domain projections in conjunction with a specific projection angle acquisition time order is reported. We performed the correction using only the PR data itself acquired with the newly proposed projection angle acquisition time order. With the proposed view angle acquisition order, the acquisition is "self-navigating" with respect to both in-plane translation and rotation. We reconstructed the images using the aligned projections and detected acquisition angles to significantly reduce image artifacts due to such motion. The theory of the correction technique is described, and its effectiveness is demonstrated in phantom and in vivo experiments.

Algorithms↗

Interscan registration using navigator echoes.

A common problem in clinical MRI is anatomic misalignment of imaging slices across successive examinations. This unnecessarily complicates the radiologic assessment of anatomic change over time on serial MRI studies. To address this problem, spherical navigator echoes, which can detect rigid body motion in all six degrees of freedom, were used to guide spatial location and orientation adjustments to an exam prescription to match the reference frame of images acquired in an earlier exam. An initial linear navigator echo is also necessary to effect coarse Z translation adjustments prior to fine six degrees of freedom adjustment with a spherical navigator echo. Results of this technique are presented for head image volumes of five volunteers. Each volunteer was imaged on two scanners. In all cases, the reference frame adjustments provided by the navigator echoes substantially improved the alignment of the latter exam and performed well compared to retrospective image-based registration.

Algorithms↗

Methodological considerations for measuring rates of brain atrophy.

PURPOSE: To systematically compare two techniques for measuring brain atrophy rates from serial magnetic resonance imaging (MRI) studies. MATERIALS AND METHODS: Using the separation in atrophy rate between cohorts of cognitively normal elderly subjects and patients with Alzheimer's disease (AD) as the gold standard, we evaluated 1) different methods of computing volume change; 2) different methods for steps in image preprocessing-intensity normalization, alignment mask used, and bias field correction; 3) the effect of MRI acquisition hardware changes; and 4) the sensitivity of the method to variations in initial manual volume editing. For each of the preceding evaluations, measurements of whole-brain and ventricular atrophy rates were calculated. RESULTS: In general, greater separation between the clinical groups was seen with ventricular rather than whole-brain measures. Surprisingly, neither the use of bias field correction nor a major hardware change between the scan pairs affected group separation. CONCLUSION: Atrophy rate measurements from serial MRI are candidates for use as surrogate markers of disease progression in AD and other dementing neurodegenerative disorders. The final method has excellent precision and accurately captures the expected biology of AD-arguably the two most important features if this technique is to be used as a biomarker of disease progression.

Adult↗

Shear stiffness estimation using intravoxel phase dispersion in magnetic resonance elastography.

Dynamic MR elastography (MRE) is a phase-contrast technique in which the periodic shear motion of an object is encoded as variations in the phase of the reconstructed images. An alternative MRE method is presented whereby waves are depicted as intensity variations in the magnitude images due to intravoxel phase dispersion (IVPD). A theoretical framework is developed to model how the IVPD magnitude data are related to the underlying shear wave motion, and how they can be used to estimate shear stiffness. The results are shown in a series of phantom experiments to demonstrate that IVPD MRE complements phase-contrast MRE.

Agar↗

Spherical navigator echoes for full 3D rigid body motion measurement in MRI.

We developed a 3D spherical navigator (SNAV) echo technique that can measure rigid body motion in all six degrees of freedom simultaneously by sampling a spherical shell in k-space. 3D rotations of an imaged object simply rotate the data on this shell and can be detected by registration of k-space magnitude values. 3D translations add phase shifts to the data on the shell and can be detected with a weighted least-squares fit to the phase differences at corresponding points. MRI pulse sequences were developed to study k-space sampling strategies on such a shell. Data collected with a computer-controlled motion phantom with known rotational and translational motions were used to evaluate the technique. The accuracy and precision of the technique depend on the sampling density. Roughly 2000 sample points were necessary for accurate detection to within the error limits of the motion phantom when using a prototype time-intensive sampling method. This number of samples can be captured in an approximately 27-ms double excitation SNAV pulse sequence with a 3D helical spiral trajectory. Preliminary results with the helical SNAV are encouraging and indicate that accurate motion measurement suitable for retrospective or prospective correction should be feasible with SNAV echoes.

Humans↗

Motion correction using the k-space phase difference of orthogonal acquisitions.

Rigid body translations of an object in MRI create image artifacts along the phase-encode (PE) direction in standard 2DFT imaging. If two images are acquired with swapped PE direction, it is possible to determine and correct for arbitrary in-plane translational interview motions in both images directly from phase differences in the k-space acquisitions by solving a large system of linear equations. For example, if one assumes two N x N 2D acquisitions with in-plane translational interview motion, 4N unknown motions may corrupt the two images, but the phase difference at each point in k-space yields a system of N(2) equations in these 4N unknowns. If the acquisitions have orthogonal PE directions, this highly overdetermined system of equations can be solved to provide the motion records, which in turn can be used to correct the motion artifacts in each image. The theory of this orthogonal k-space phase difference (ORKPHAD) technique is described, and results are presented for synthetic and in vivo motion-corrupted data sets. In all cases, the data showed clear improvement of translation-induced artifacts. These methods do not require special pulse sequences and are theoretically generalizable to partial Fourier imaging and 3D acquisitions.

Artifacts↗

MR elastography of breast cancer: preliminary results.

OBJECTIVE: Motivated by the long-recognized value of palpation in detecting breast cancer, we tested the feasibility of a technique for quantitatively evaluating the mechanical properties of breast tissues on the basis of direct MR imaging visualization of acoustic waves. SUBJECTS AND METHODS: The prototypic elasticity imaging technique consists of a device for generating acoustic shear waves in tissue, an MR imaging-based method for imaging the propagation of these waves, and an algorithm for processing the wave images to generate quantitative images depicting tissue stiffness. After tests with tissue-simulating phantom materials and breast cancer specimens, we used the prototypic breast MR elastography technique to image six healthy women and six patients with known breast cancer. RESULTS: Acoustic shear waves were clearly visualized in phantoms, breast cancer specimens, healthy volunteers, and patients with breast cancer. The elastograms of the tumor specimens showed focal areas of high shear stiffness. MR elastograms of healthy volunteers revealed moderately heterogeneous mechanical properties, with the shear stiffness of fibroglandular tissue measuring slightly higher than that of adipose tissue. The elastograms of patients with breast cancer showed focal areas of high shear stiffness corresponding to the locations of the known tumors. The mean shear stiffness of breast carcinoma was 418% higher than the mean value of surrounding breast tissues. CONCLUSION: The results confirm the hypothesis that the prototypic breast MR elastographic technique can quantitatively depict the elastic properties of breast tissues in vivo and reveal high shear elasticity in known breast tumors. Further research is needed to evaluate the potential applications of MR elastography, such as detecting breast carcinoma and characterizing suspicious breast lesions.

Adult↗

Motion-correction techniques for standing equine MRI.

Magnetic resonance imaging (MRI) of the distal extremities of the standing, sedated horse would be desirable if diagnostic quality images could be obtained. With the availability of extremity and special purpose magnet designs on the market, a system to safely accommodate the standing horse may gain increasing popularity. This paper considers the issue of motion that will need to be addressed to achieve successful, diagnostic quality images. The motion of the carpus and tarsus of five standing, sedated horses was quantified. The obtained motion records were then used to induce motion in cadaveric joint specimens during several MRI scans. The measured dorsal-palmar/plantar, medial-lateral, and proximal-distal random wobbling motions in the standing sedated horse were several centimeters in magnitude and generated severe motion-artifacts during axial MRI of the cadaveric specimens. Two retrospective motion-correction techniques (autocorrection and navigator-based adaptive correction) were used to correct the corrupted images. The motion artifacts were nearly eliminated with the use of both techniques in series. Although significant hurdles remain, these results suggest promise for allowing diagnostic quality MRI of the carpus and tarsus in the standing horse.

Animals↗