PubMed Health⌕ Search

Biomedical subjects

Arnab Sinha

Publications and source records attributed to Arnab Sinha.

4 recordsLinked to original sources

High-resolution volume holographic profilometry using the Viterbi algorithm.

We use the Viterbi decoding algorithm to resolve depth features beyond the nominal resolution limit of a volume holographic profilometry system. The formulation treats the truncated point-spread function as an intersymbol interference and uses surface constraints and transition constraints to reduce the computational complexity. A factor-of-5 improvement in resolution was obtained in our experimental demonstration.

Journal Article↗

N-ocular volume holographic imaging.

Volume holographic imaging utilizes Bragg selectivity to optically slice the object space of the imaging system and measure four- (three spatial and one spectral) dimensional object information. The N-ocular version of this method combines multiple-volume holographic sensors and digital postprocessing to yield high-resolution three-dimensional images for broadband objects located at long working distances. We discuss the physical properties of volume holography pertinent to imaging performance and describe two computational algorithms for image inversion based on filtered backprojection and least-squares optimization.

Journal Article↗

Broadband volume holographic imaging.

We demonstrate transmission geometry volume holograms working under broadband illumination. We show that increased illumination bandwidth enhances the lateral field of view of planar reference holograms. We exploit this phenomenon to design volume holographic spectrum analyzers and present results from an experimental prototype. Furthermore, we show that there is a trade-off involved, because an improvement in the field of view results in a reduction of image contrast as a function of depth. We experimentally demonstrate this trade-off and discuss possible ways to overcome it.

Journal Article↗

Volume holographic imaging in transmission geometry.

We address the performance of transmission geometry volume holograms as depth-selective imaging elements. We consider two simple implementations using holograms recorded with spherical and plane beams. We derive the point-spread function (PSF) of these systems using volume diffraction theory and use the PSF to estimate depth resolution. Furthermore, we show that appropriately designed objective optics can significantly improve the depth resolution or the working distance of plane-wave reference holographic imaging systems. These results are confirmed experimentally and demonstrated for objects with millimeter axial features, imaged from the 5- to 50-cm range.

Journal Article↗