PubMed Health⌕ Search

Biomedical subjects

Arne Viestenz

Publications and source records attributed to Arne Viestenz.

At least 19 recordsLinked to original sources

Measurement of autofluorescence in the parapapillary atrophic zone in patients with ocular hypertension.

PURPOSE: The purpose of the study was to investigate area and intensity of parapapillary autofluorescence in patients with ocular hypertension and controls. PATIENTS AND METHODS: Forty-two consecutive patients with ocular hypertension and 25 controls were investigated in a controlled prospective cross-sectional trial. All patients and controls were members of the Erlangen Glaucoma registry and received complete ophthalmologic examination and detailed standardized glaucoma examination, including 24-h IOP measurement, perimetrie (G1, three phases) and 15 degrees stereographic slides of the optic disc. Additionally, patients and controls were investigated with VEP with blue on yellow pattern stimulation and confocal scanning laser ophthalmoscope (HRA II, Heidelberg Engineering, Dossenheim, Germany) to detect lipofuscin in the parapapillary atrophic zone. Eyes with retinal diseases or pathologic changes of retinal pigmentepithelium were excluded. Extension of parapapillary area with increased autofluorescence compared (qualitatively) to background autofluorescence around the optic disc and the level of autofluorescence (quantitatively) in the area of qualitatively increased autofluorescence was measured. Patients and controls did not differ significantly concerning age. RESULTS: The area of parapapillary autofluorescence was significant larger in patients with ocular hypertension than in the control group (0.21+/-0.17 mm(2) versus 0.07+/-0.06 mm(2); P<0.001, Mann-Whitney U-test). An increased latency of blue-on-yellow pattern VEP was seen in patients with OHT with increasing parapapillary autofluorescence area (r=0.496; P<0.001, Spearman-Rho test). CONCLUSION: Parapapillary autofluorescence is increased in patients with ocular hypertension. Patients with large area of parapapillary autofluorescence had also an increased latency in blue on yellow pattern VEP.

Cross-Sectional Studies↗

Ray tracing through a schematic eye containing second-order (quadric) surfaces using 4 x 4 matrix notation.

Ray tracing is used in ophthalmology for evaluation of the optical properties of the eye. We demonstrate an algebraic method for tracing a bundle of rays through the optical system of an eye containing aspheric surfaces. Restricting to second-order surfaces (quadric surfaces) such as ellipsoids, paraboloids or hyperboloids, a surface is described by a 4 x 4 matrix. In this case, the normal vector can be derived analytically and the ray-surface intersection is calculated by solving a quadratic equation. We applied this straightforward matrix-based strategy to the spherical 4-surface Le Grand schematic eye, and the Le Grand eye modified by Kooijman containing four aspheric surfaces. We calculated the spot diagram for the focal plane as well as a pre- and post-focal plane for both model eyes, and found that the optical quality of the aspheric model characterized by the ray scatter in the spot diagram at the focal plane is much better than that of the spherical model. This calculation strategy may be helpful for evaluating the image distortion of decentred or tilted spherical or aspheric artificial intra-ocular lenses.

Cornea↗

Influence of optic disc size on parameters of retinal nerve fiber analysis with laser scanning polarimetry.

PURPOSE: The aim of the study was to evaluate the influence of optic disc size on the variables of laser scanning polarimetry (GDx). PATIENTS AND METHODS: One hundred and nineteen healthy controls and 161 patients with ocular hypertension (OHT) received detailed ophthalmologic investigation with respect to glaucoma including retinal nerve fiber analysis with GDx (Version 3.0.05x1; Laser Diagnostic Technologies Europe). Optic disc size was measured with planimetry using 15 degrees optic disc photographs. With respect to frequency of optic disc size in the normal population patients were divided in quartiles of equal sample size. RESULTS: The ratio between retinal nerve fiber layer thickness in the superior and inferior areas in relation to the nasal and temporal regions decreases significantly with increasing optic disc size and the difference between the highest and lowest retinal nerve fiber layer thickness decreases significantly with increasing optic disc size. The results of multivariate neural network analysis increased with larger optic disc size in controls as well as in patients with OHT. Linear regression analysis showed an increase of 9 units (the Number) per 1 mm(2) of optic disc size. A Number above 30, which indicates suspected glaucoma, was detected in more than a third of the normal population investigated if the optic disc area was larger than 3.5 mm(2). Overall, patients with OHT had a higher Number than controls (20.5+/-11.5 vs. 18.1+/-10.4; p>0.05), but the difference between the two groups did not reach a significant level. CONCLUSIONS: Retinal nerve fiber analysis in patients with an optic disc size larger than 3.5 mm(2) should be interpreted carefully; the Number in particular requires corrections for optic disc size.

Adolescent↗

Inverse mushroom-shaped nonmechanical penetrating keratoplasty using a femtosecond laser.

PURPOSE: To demonstrate the feasibility of an inverse mushroom-shaped nonmechanical corneal trephination using a femtosecond laser in a noncontact manner. DESIGN: Experimental study. METHODS: In this laboratory study, 10 polymethylmethacrylate (PMMA) blocks and 20 porcine corneas were treated with an industrial femtosecond laser source. The trephination profile consisted of (1) a 7- or 6-mm diameter cylinder from the anterior chamber, (2) an intermediate horizontal connecting plane, and (3) a concentric 5- or 4-mm diameter cylinder upwards. RESULTS: Applying appropriate combinations of pulse energy and spacing, trephination took less than 60 seconds. In porcine eyes, light microscopy displayed trephination edges delineated by partly confluent gas bubbles (10-40 mum) with tissue bridges in between. By TEM, the cut edges were lined by a delicate, electron-dense layer (5-40 nm). CONCLUSIONS: Femtosecond laser technology seems to offer a promising approach towards minimally invasive self-sealing "no-stitch keratoplasty."

Agaricales↗

Evaluating the eye's rotational stability during standard photography: effect on determining the axial orientation of toric intraocular lenses.

PURPOSE: To evaluate the rotational stability of the eye during standard photography and determine its effect on the measurement of toric intraocular lens (IOL) orientation. SETTING: Department of Ophthalmology, University Erlangen-Nuremberg, Erlangen, Germany. METHODS: The rotational stability of the eye was evaluated using standard photographs taken with a telecentric fundus camera (Zeiss). Two sets of fundus images were taken at least 6 months apart in 400 eyes of 200 patients. The axial position of the eye was determined using 2 characteristic markers of the fundus. The angle between the 2 images (autorotation angle) was measured in each eye. RESULTS: The mean absolute autorotation was 2.3 degrees +/- 1.7 (SD) (range 0 to 11.5 degrees). Nine percent of eyes did not rotate. The rotation was less than 3 degrees in 55% of eyes and was 3 degrees or greater in 36% of eyes. Eyes of patients younger than 50 years rotated less than eyes in older patients (mean 2.2 +/- 1.5 degrees and 2.5 +/- 1.8 degrees, respectively) (P=.04). A visual acuity of 20/20 or better (P=.02) and a refractive cylinder of less than 1.75 diopters (P=.01) were correlated with smaller amounts of autorotation. Potential causes of artificial eye rotation induced by the photographic technique included camera adaptation (3-degree intrinsic error), slide mounting (<1 degree), slide projection (<0.5 degree), marking of characteristic fundus details (<1 degree), and head inclination. CONCLUSIONS: Cyclorotation of the eye during standard photography may lead to overestimation or underestimation of the presumed spontaneous rotation of an implanted toric IOL. Results show that 11.5 degrees of toric IOL rotation would lead to residual astigmatism that is 40% of the initial astigmatic power and 3 degrees, 10% of the initial power. Digital imaging may reduce the intrinsic errors of standard photography.

Adolescent↗

Association between localized visual field losses and thickness deviation of the nerve fiber layer in glaucoma.

PURPOSE: To perform a correlation between morphology and function by studying local perimetric field losses and thickness reduction of the nerve layer in corresponding areas. METHOD: Forty-seven patients with "preperimetric" open-angle glaucoma, 95 patients with "perimetric" open-angle glaucoma, and 75 control subjects had perimetric (Octopus) and polarimetric measurements. Criteria for exclusion: optic discs larger than 4 mm, media opacities, polarimetric hourglass pattern in the macular image. Thickness values of the retinal nerve fiber layer were determined in 14 upper and 14 lower sectors (10 degrees each) as well as nasally and temporally (40 degrees each) as provided from the GDx (software version 4000). The healthy control subjects served to determine age-corrected thickness deviation in all sectors. Analyses were calculated in eight nerve fiber bundle related areas. Due to non-linear relationships between perimetric defects and corresponding thickness deviation non-parametric tests were used. RESULTS: Localized visual field defects in the present perimetric patients were highest in upper and lower visual field areas abutting the nasal meridian. Thickness loss of nerve fiber layer however was highest in more circumferential upper and lower nerve fiber bundles. Correlations between local mean defects and deviation of the retinal nerve fiber layer thickness from normals showed a clear association for corresponding areas. The correlation coefficients were significant (P < 0.01) for all arcuate superior and inferior visual field zones except horizontally and not for the area of the lower nasal step. CONCLUSION: The present correspondence map indicates that focal perimetric defects can be identified best polarimetrically if they occur in the arcuate bundles of the visual field. A lack of correspondence was observed in the area of the papillo-macular bundle.

Female↗

Tapioca melanoma of the iris mimicking a vascular tumour: a clinicopathological correlation.

Although vascular iris processes are usually benign, they may be a clinical manifestation of iris melanoma, and this should be considered in the differential diagnosis. The case is reported of a 20-year-old man with a highly vascularized tapioca melanoma of the left iris without involvement of the anterior chamber angle or ciliary body, but with observed growth tendency. Sector iridectomy was performed 2 months after first examination. In addition, two separate floating tumour nodules were observed in the anterior chamber angle at 6 o'clock and were removed by aspiration. After 1 year follow up, no recurrence of melanoma cells was observed. In tapioca iris melanomas, diagnostic differentiation from congenital, inflammatory, vascular and neoplastic iris processes is required. Careful biomicroscopic examination of the iris in patients with vascular iris tumours may help the ophthalmologist to identify malignant iris melanomas (tapioca type) and plan appropriate surgical treatment.

Adult↗

Comparison between central corneal thickness and IOP in patients with macrodiscs with physiologic macrocup and normal-sized vital discs.

BACKGROUND: Macrodiscs with physiologic macrocups and elevated intraocular pressure (IOP) are frequently suspicious for glaucoma. Patients with an elevated c/d ratio and an IOP of more than 21 mmHg are often treated for glaucoma. We investigated a possible relationship between macrodiscs, IOP and central corneal thickness. METHODS: Using the Erlangen glaucoma registry, 341 out of 1,096 consecutive patients with unremarkable and repeated visual field (Octopus 500, G1-3, MD<2.1) were selected. Most of these patients had been sent as glaucoma suspects. The following data were collected: corneal ultrasound pachymetry (Tomey, AL-2000), IOP profile, visual acuity and central corneal power. The morphometric analysis was performed by planimetry using the Littmann formula. Optic nerve heads with a disc area of more than 3.1 mm(2) were defined as macrodiscs. RESULTS: Patients were subdivided into the following groups: group A: healthy macrodiscs, IOP <22 mmHg (87 patients); group B: healthy macrodiscs, IOP >21 mmHg (66 patients); group C: normal-sized healthy discs, IOP <22 mmHg (93 patients); group D: normal-sized healthy discs, IOP >21 mmHg (95 patients). Mean corneal thickness was: group A: 575+/-36 microm, group B: 596+/-37 microm, group C: 557+/-31 microm and group D: 585+/-38 microm ( P=0.003). Mean central corneal power measured: group A: 41.7+/-1.3 D, group B: 42.4+/-1.3 D, group C: 43.0+/-1.2 D and group D: 42.8+/-1.2 D ( P<0.05). The maximum of IOP was: group A: 17.6+/-3.1, group B: 26.2+/-4.1, group C: 17.2+/-3.4 and group D: 29.7+/-5.5 mmHg. Optic disc size measurements were: group A: 3.91+/-0.66, group B: 3.65+/-0.6, group C: 2.56+/-0.30 mm(2) and group D: 2.39+/-0.39 microm, respectively. CONCLUSIONS: Macrodiscs with elevated IOP have a higher corneal curvature (mean: +0.7 D) and a thicker central cornea (mean: +21 microm) compared to macrodiscs without elevated IOP. An exact evaluation of optic disc morphology in combination with pachymetric and keratometric measurements in relation to IOP could avoid an overtreatment in patients with suspect primary open-angle glaucoma.

Case-Control Studies↗

Corneal shrinkage induced by nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty in porcine eyes.

PURPOSE: To assess the degree of corneal diameter shrinkage induced by Q-switched mid-infrared laser corneal trephination for penetrating keratoplasty in an experimental model. METHODS: Corneal trephination was performed in 80 enucleated porcine eyes fixed in a holder centered on an automated globe rotation device, by Q-switched (2.94 microm) Er:YAG laser along open masks. Four types of masks were used to protect the underlying corneal tissue: metal masks (donor and recipient) and ceramic masks (donor and recipient). Two spot diameters (0.65 mm and 0.96 mm) were combined with two energy settings (40 mJ/pulse and 50 mJ/pulse) for each of the masks used. Repetition rate was fixed at 5 Hz. Diameters of donor buttons/recipient beds (horizontal and vertical) were measured immediately after the trephination and compared to the given mask size. RESULTS: Minimum corneal shrinkage was found in the recipient metal mask group (mean +/- SD=0.3+/-0.4%) with 50 mJ pulse energy and 0.65 mm spot diameter (in the horizontal diameter), while the maximum shrinkage (5.3+/-2.8%) was found in the donor metal mask group with 50 mJ pulse energy and 0.96 mm spot diameter. Corneal shrinkage was less pronounced in recipient beds than in donor buttons (P<0.01). The differences in shrinkage between the use of ceramic and metal masks were insignificant (P>0.05). Mean induced corneal diameter discrepancies between the donor button and the recipient bed (with metal and ceramic masks) were 2.5% and 2.5% in vertical diameter and 3.4% and 2.4% in horizontal diameter. CONCLUSIONS: The Q-switched Er:YAG laser experimental corneal trephination for penetrating keratoplasty may induce minor degrees of corneal diameter shrinkage in donor buttons and recipient openings. Oversizing of donor masks by 0.25-0.35 mm (i.e. 3-4% of graft size) may be a valid option to avoid refractive consequences.

Animals↗

Nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty: experimental study on human donor corneas.

OBJECTIVE: To assess the alterations in human donor corneal tissue induced by Q-switched erbium (Er):YAG laser corneal trephination. METHODS: Thirty human corneoscleral donor buttons unsuitable for transplantation were placed in an artificial chamber on an automated rotation device. Corneas were trephined with a Q-switched Er:YAG laser (wavelength, 2.94 microm; pulse duration, 400 nanoseconds) along (donor and recipient) aluminum silicate (ceramic) open masks. A spot diameter of 0.65 mm, energy setting of 50 mJ/pulse, and repetition rate of 5 Hz were used. Corneal thermal damage and cut regularity were quantitatively assessed in 24 corneas processed for light microscopy and by transmission and scanning electron microscopy. RESULTS: The stromal thermal damage was the highest (mean [SD], 8.0 [2.7] microm) at a 150-microm cut depth and decreased downward. Cut regularity was very good and did not significantly differ between donors and recipients. Scanning electron microscopy confirmed that the cuts were highly regular; transmission electron microscopy revealed 2 distinctive subzones within the stromal thermal damage zone. CONCLUSIONS: Thermal damage induced by Q-switched Er:YAG nonmechanical corneal trephination was low, and the regularity of the cuts was very good. CLINICAL RELEVANCE: The Q-switched Er:YAG laser may have the potential to become an alternative to the excimer laser for nonmechanical penetrating keratoplasty.

Cornea↗

[Vigabatrin-associated bilateral simple optic nerve atrophy with visual field constriction. A case report and a survey of the literature].

CASE REPORT: A 70-year-old male with optic disc pallor and visual field constriction up to 35 degrees bilaterally was previously treated with vigabatrin. The cumulative dosage was 3.7 kg. The b-wave was reduced in photopic and scotopic electroretinography and the patient had delayed visual evoked potentials. The retinal nerve fiber thickness was pathologically reduced in the Heidelberg retinal tomography (HRT) and the retinal nerve fiber layer analyzer (GDx). CONCLUSION: Vigabatrin is an antiepileptic drug and may increase the intraretinal GABA level due to an inhibition of the enzyme GABA-transaminase and may induce an ascending simple optic nerve atrophy. Vigabatrin-associated visual field defects may be irreversible. A visual field control is recommended before starting the treatment with vigabatrin and at regular 6-month intervals thereafter. In cases of visual field constriction, the therapy should be stopped. If the cumulative dosage is more than 3 kg of vigabatrin, the visual field controls should be performed more frequently because of the dosage-toxicity relationship.

Aged↗

[Impact of an Er:YAG laser beam control on cut quality of non-mechanical corneal trepanation for penetrating keratoplasty].

BACKGROUND: Results of non-mechanical corneal trepanation using the excimer laser enhance the morphological and functional results for penetrating keratoplasty. Searching for alternative laser sources we assessed the impact of an automatic laser beam control for the Er:YAG solid-state laser on the cut performance and thermal damage zone in non-mechanical corneal trepanation. METHODS: We compared the cut quality of A) a manually guided laser beam, B) a semiautomatically guided laser beam and C) a fully PC-controlled laser beam positioning system (q-switched, repetition rate 5 Hz, pulse energy 65 mJ, spot size 0.7 mm) along slit aperture masks on 28 rabbit eyes using macroscopic images and histological sections (PAS staining). RESULTS: The manually guided laser beam control (A) induced the broadest thermal damage zone in the corneal stroma (19.3+/-8.7 microm) compared to the semi-automatic mode (B) (8.8+/-3.0 microm, p=0.03) and the PC-controlled laser beam control (C) (7.0+/-3.0 microm, p=0.016). CONCLUSION: The fully automatic PC-controlled laser beam positioning system for the Er:YAG solid-state laser with a small spot size and fixed low repetition rate allows a precise laser beam guidance and a significant enhancement of the cut performance compared to a manual laser beam control via micromanipulator in experimental nonmechanical corneal trepanation.

Animals↗

Evaluation of corneal flap dimensions and cut quality using the SKBM automated microkeratome.

PURPOSE: To evaluate flap dimensions and cut quality with repeated blade use of the automated Summit Krumeich-Barraquer microkeratome (SKBM [LadarVision]). SETTING: Department of Ophthalmology, University Erlangen-Nuremberg, Erlangen, Germany. METHODS: The SKBM (160 microm plate, intended flap diameter 9.0 mm) was used to perform a corneal hinged flap in 35 pig cadaver eyes. Seven blades were reused 5 times each. The flap diameter was measured by planimetry, and the thickness was assessed by ultrasonic pachymetry. Scanning electron microscopy (SEM) of blades and stromal beds was performed. RESULTS: With single use of the blade, the mean central flap thickness was 145 microm +/- 25 (SD). The vertical/horizontal flap diameter was 9.0 +/- 0.03 mm/8.6 +/- 0.03 mm. No thickness gradient was observed from the incision (138 +/- 31 microm) to the flap hinge (130 +/- 30 microm). If the blade was used more than 2 times, the flap was thinner at the incision (157 +/- 34 microm versus 124 +/- 20 microm; P =.003) and the hinge (143 +/- 24 microm versus 122 +/- 31 microm; P =.04), but the central thickness remained unchanged. With multiple use of the blade, SEM analysis showed increasing cut irregularity, more tissue remnants on the blade surface, and a progression in blade irregularities (up to 9.3 microm). CONCLUSIONS: Reproducible flap size and thickness can be obtained with single use of stainless steel blades in the SKBM. With multiple use, the quality of the blades and the stromal bed deteriorates and the peripheral thickness of the flaps decreases. Thus, single use of blades is recommended.

Animals↗

Computerised calculation scheme for ocular magnification with the Zeiss telecentric fundus camera.

Littmann (1982) described a method to determine the magnification of the eye in order to relate the size of a retinal feature to its measured image size on a telecentric fundus camera film. This required information only about ametropia and corneal curvature. Several other methods have been reported since then which consider other biometric data to enhance the accuracy of this classical method. The purpose of this study is to describe a numerical calculation scheme to determine the magnification q of the eye in two cardinal meridians using paraxial raytracing. Our calculation scheme is based on ametropia, keratometry, as well as biometric data such as axial length, anterior chamber depth and thickness of the crystalline lens. It is described step-by-step in order (1) to determine the refractive powers of both surfaces of the crystalline lens, which are not directly measurable in vivo, (2) to derive the retinal image conjugate to a circular object using paraxial raytracing, (3) to fit an ellipse to the retinal image, (4) to determine the secondary principal points (Gaussian length) separately for both cardinal meridians and (5) to calculate the ocular magnification q. The power of the crystalline lens is estimated to compensate for the spherocylindrical refraction at the spectacle plane and the corneal refraction with an astigmatic component thus creating a sharp image focused at the retinal plane. The capabilities of this computing scheme are demonstrated with five clinical examples and are related to the respective values of the classical Littmann formula as well as to enhanced methods described by Bennett (1988), Bennett et al. (1994) and Garway-Heath et al. (1998).

Anterior Chamber↗

[Block excision of epithelial ingrowth after cataract surgery--report on 15 patients].

BACKGROUND: Cystic or diffuse epithelial ingrowth into the anterior chamber after cataract surgery is a rare complication. It can lead to painful secondary glaucomas or in case of fistulation to persisting ocular hypotony or atrophy of the globe due to wrong or inadequate therapy. PATIENTS AND METHODS: The cause of epithelial ingrowth was a previous cataract surgery in 15 of 59 patients (25 %, Erlangen Block-Excision Registry for epithelial ingrowth). Eleven patients were females. Mean age was 65 +/- 13 years. RESULTS: Ten patients underwent block excision of epithelium, adjacent iris, ciliary body, sclera or cornea due to epithelial ingrowth following intracapsular cataract extraction between 1980 and 1987 and five patients since 1987 because of epithelial ingrowth following extracapsular cataract extraction (4 with and 1 without intraocular lens implantation); all primary cataract surgeries had been performed in external hospitals. We found a diffuse invasion in 3 eyes (all following icCE) and a cystic epithelial invasion in 12 eyes histologically. Mean time interval between cataract surgery and block excision was 7 +/- 8 years (range: 1 to 33 years). The excisional defect in the globes wall was covered using a tectonic corneoscleral graft (diameter: 8.0 +/- 1.8 mm). Postoperative astigmatism was 3.6 +/- 3.4 dpt. Six eyes had postoperatively a visual acuity of 20/200 or better. No recurrence of epithelial downgrowth was observed, nor was an enucleation needed. CONCLUSION: Surgical procedures with opening of the cyst (e.g. laser) are contraindicated and may lead to a transformation from cystic into diffuse epithelial invasion with potential blindness. The therapy of first choice in eyes with cystic epithelial ingrowth and an extension less than five clock hours is the curative block-excision technique combined with tectonic corneoscleral graft. Surgical results are excellent in order to regard a curative excision and the survival of the eye with acceptable achieved function in consideration of the difficult primary situation with intra- and postoperative complications due to previous cataract surgery.

Aged↗

[Ocular manifestation in LCAT deficiency--a clinicopathological correlation].

BACKGROUND: Bilateral stromal corneal opacifications are important to detect potentially associated systemic diseases. Differential diagnosis includes, besides inflammatory diseases mucopolysaccharidoses, HDL deficiencies (LCAT deficiency, Tangier disease and fish eye disease), Schnyder's crystalline corneal dystrophy, lipid keratopathy, cystinosis, gout and mucolipidoses. CASE REPORT: The cornea of a 60-year old male patient, 180 cm height, showed milky hazy diffuse stromal inclusions with a prominent lipoid arc (VA O. D. 20/30 and O. S. 20/40, contre-jour VA less than 20/150). Ten years earlier, lattice corneal dystrophy was diagnosed. The cornea was thickened (0.61 mm). Except for the cornea, the anterior and posterior segments of the eye were unremarkable. Serum HDL concentration was decreased pathologically (7 mg/dl), although the LCAT activity was combined with apo-AI deficiency. Due to membrane instability, the erythrocytes showed target cell configuration. Penetrating excimer-laser keratoplasty was performed O. S. The epithelial wound closed only on the 32nd postoperative day. Histologically, the corneal stroma showed multiple vacuoles and amyloid deposits. Genetic analysis revealed two mutations in chromosome 16. CONCLUSION: To our knowledge, this is the second description in the literature of a patient with LCAT deficiency and secondary amyloidosis of the cornea. Additionally, LCAT deficiency is associated with anaemia and proteinuria. After a penetrating keratoplasty, prolonged wound healing is possible. Because of the bilateral corneal clouding, the ophthalmologist may help to identify patients with LCAT deficiency. Thus, it is possible to start antiarteriosclerotic therapy.

Amyloidosis, Familial↗

[In-vivo measurement of autofluorescence in the parapapillary atrophic zone of optic discs with and without glaucomatous atrophy].

BACKGROUND: To assess the level of autofluorescence (lipofuscin) of atrophic parapapillary zones in different stages of glaucomatous optic disc atrophy. METHODS: Controlled cross-sectional prospective analysis of 79 consecutive eyes (15 normals as controls, 26 with ocular hypertension, 38 with primary open angle glaucoma). Eyes with retinal diseases or retinal pigment epithelial pathologies were excluded. The confocal scanning laser ophthalmoscope (HRA, Heidelberg Retina Angiograph) was used after lipofuscin excitation with argon blue laser (488 nm) to detect parapapillary autofluorescence in a spectrum above 500 nm. Size, extension of the parapapillary autofluorescent area and its mean distance to the optic nerve head were measured using the HRA standard software. Additional optic nerve head photographs taken with the 15 degrees Zeiss telecentric fundus camera (30 degrees camera with 2 x magnifier) were examined by two experienced ophthalmologists to determine the stage of glaucomatous optic disc atrophy (stages 0 to 4). RESULTS: Very small autofluorescent areas were found in vital discs (optic nerve glaucoma stage 0) in the parapapillary atrophic area (0.08 +/- 0.12 mm (2)) in contrast to glaucomatous discs in stage 1 (0.24 +/- 0.26 mm (2)) and stages 2, 3 and 4 (0.59 +/- 1.29 mm (2), logistic regression analysis r = 0.71; P = 0.029). The circular extension of the autofluorescent area correlated borderlined with the stage of the glaucomatous disc atrophy (higher glaucoma stages: r = 0.82; P = 0.09). The autofluorescent area was larger in OHT than in controls (0.11 mm (2) vs. 0.04 mm (2), P < 0.03). The circular extension of the autofluorescent area was longer in OHT than in controls (0.5 mm vs. 1.15 mm, P < 0.04). CONCLUSIONS: As a sign of pronounced lipofuscin accumulation in the parapapillary atrophic zone higher degrees of fundus autofluorescence can be detected in OHT and manifest primary open angle glaucoma in contrast to normals. The lipofuscin accumulation is correlated with the stage of progression of glaucoma and the stage of optic disc atrophy. The detection of active parapapillary autofluorescent areas especially in OHT may offer the ophthalmologist an important tool for early diagnosis.

Adult↗