PubMed Health⌕ Search

Biomedical subjects

Arno Buecker

Publications and source records attributed to Arno Buecker.

At least 19 recordsLinked to original sources

Reliable 5-min real-time MR technique for left-ventricular-wall motion analysis.

The aim of this study was to investigate the value of a real-time magnetic resonance imaging (MRI) approach for the assessment of left-ventricular-wall motion in patients with insufficient transthoracic echocardiography in terms of accuracy and temporal expenditure. Twenty-five consecutive patients were examined on a 1.5-Tesla whole-body MR system (ACS-NT, Philips Medical Systems, Best, NL) using a real-time and ECG-gated (the current gold standard) steady-state free-precession (SSFP) sequence. Wall motion was analyzed by three observers by consensus interpretation. In addition, the preparation, scanning, and overall examination times were measured. The assessment of the wall motion demonstrated a close agreement between the two modalities resulting in a mean kappa coefficient of 0.8. At the same time, each stage of the examination was significantly shortened using the real-time MR approach. Real-time imaging allows for accurate assessment of left-ventricular-wall motion with the added benefit of decreased examination time. Therefore, it may serve as a cost-efficient alternative in patients with insufficient echocardiography.

Aged↗

The value of non-contrast harmonic transthoracic echocardiography for the detection of left ventricular thrombi in patients with cardiomyopathy: comparison with contrast-enhanced magnetic resonance imaging.

We sought to assess the value of non-contrast enhanced transthoracic harmonic echocardiography (TEE) for the visualization of left ventricular thrombi in 34 patients with cardiomyopathy. Results were compared to contrast-enhanced magnetic resonance imaging as reference standard. Maximal thrombus size was quantified with both modalities. Magnetic resonance imaging demonstrated thrombi in 15 patients. In these subjects echocardiography was negative in seven patients. Thrombi were excluded in 19 patients with magnetic resonance while echocardiography was deemed positive in 5 subjects. Thrombus size by ce-CMR was not different for clots visualized or not visualized by echocardiography (P = 0.71). Moreover, observer agreement was superior for ce-CMR (kappa = 0.94) as compared to TTE (kappa= 0.71). Non-contrast-enhanced harmonic TTE has limited value for the visualization of thrombi in patients with cardiomyopathy.

Adult↗

Assessment of reversible myocardial dysfunction in chronic ischaemic heart disease: comparison of contrast-enhanced cardiovascular magnetic resonance and a combined positron emission tomography-single photon emission computed tomography imaging protocol.

AIMS: The aim of the study was to compare, in patients with chronic ischaemic cardiomyopathy, contrast-enhanced cardiovascular magnetic resonance (ce-CMR) imaging and a combined (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and (99m)Tc-sestamibi single-photon emission computed tomography (SPECT) protocols for the prediction of functional recovery after revascularization, as assessed by cine CMR. METHODS AND RESULTS: Twenty-nine patients with ischaemic cardiomyopathy (ejection fraction 32 +/- 10%) were investigated with ce-CMR and PET/SPECT. For the assessment of global and regional functions, cine CMR was performed at baseline and at 6 months follow-up. For ce-CMR, the segmental extent of hyperenhancement (SEH) was quantitated, and for PET/SPECT, different viability categories were defined according to a validated quantitative protocol. Functional improvement was related to the SEH by ce-CMR, as well as to the viability categories by PET/SPECT. Sensitivity and specificity for the prediction of functional recovery at follow-up was 97 and 68% for ce-CMR and 87 and 76% for PET/SPECT. The positive predictive value was identical for both techniques (73%). However, ce-CMR achieved a higher negative predictive value (93 vs. 77%, respectively), indicating that ce-CMR may be superior to PET/SPECT for the identification of segments unlikely to recover function after revascularization. Both methods had a similar yield in the prediction of global functional improvement. CONCLUSION: ce-CMR is comparable with a PET/SPECT imaging protocol for the prediction of regional and global functional improvement after revascularization. However, ce-CMR may be superior to nuclear imaging for the identification of segments that are unlikely to recover function at follow-up.

Chronic Disease↗

MR coronary vessel wall imaging: comparison between radial and spiral k-space sampling.

PURPOSE: To compare radial and spiral k-space sampling in navigator-gated ECG-triggered three-dimensional (3D) coronary vessel wall imaging. MATERIALS AND METHODS: The right coronary artery (RCA) vessel walls of eight healthy subjects were imaged using a modified double-inversion prepulse in concert with radial and spiral data acquisition. For data analysis, two investigators blinded to the sequence parameters subjectively assessed image quality in terms of artifacts and vessel wall visualization. Objective measures of the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and vessel wall definition were also determined. RESULTS: Radial k-space sampling demonstrated fewer artifacts and led to improved visualization of the coronary vessel wall compared to spiral imaging (P < 0.05). This finding was also reflected in a better vessel wall definition using radial data acquisition (P < 0.05). SNR and CNR were found to be higher when spiral k-space sampling was used (n.s.). CONCLUSION: Radial k-space sampling in concert with free-breathing navigator-gated cardiac-triggered MRI of the coronary vessel wall resulted in fewer motion artifacts and improved vessel wall definition compared to spiral k-space sampling. The proposed approach therefore appears to be preferable.

Adult↗

Automatic selection of the optimal cardiac phase for gated three-dimensional coronary x-ray angiography.

RATIONALE AND OBJECTIVES: For the reconstruction of the coronary arteries from rotational angiography data, a crucial point is the selection of the optimal cardiac phase for data reconstruction. To avoid time-consuming interactive selection of the optimal cardiac phase by visual inspection of multiple high-resolution data sets reconstructed at different cardiac phases, an automatic approach for deriving optimal reconstruction windows is attractive. MATERIALS AND METHODS: This paper presents a new approach to fully automatic selection of the optimal cardiac phase for image reconstruction. It is based on the analysis of a four-dimensional data set of the region of interest reconstructed at low-spatial resolution utilizing an image quality index, which quantifies the image quality of a single three-dimensional reconstructed volume. The derived image quality index utilizes the histogram information of a single temporal snapshot as a quality measure for the vessel reconstruction. The proposed technique was applied to 16 projection data sets obtained in eight pigs. RESULTS: Experiments to evaluate the proposed method based on user-defined image quality parameters serving as ground truth, showed a relatively high correlation (>84%) for high-quality (c(phi) > 0.95) images. CONCLUSION: An image-based technique is introduced, which is able to determine the optimal cardiac phase for 3D-RCA fully automatically. The proposed method was successfully applied to 16 data sets obtained in a total of 8 porcine models.

Algorithms↗

Safety of MRI-guided vascular interventions.

Longer electrically conducting parts are needed for various instruments such as pacemakers, defibrillators, deep brain stimulators and interventional instruments. Magnetic resonance imaging in the presence of these instruments can be potentially harmful, due to resonance effects and heating of conducting wires. A review of the literature revealed that neither manufacturers of pacemakers and defibrillators nor the FDA consider these medical instruments to be MR-safe, despite the fact that there are some reports about MR scanning of pacemaker patients without critical incidents. MR-guided angiographic interventions require not only high quality real-time imaging, but also MR compatible and MR-safe instruments. Consequently, metallic guidewires as used for angiographic interventions were examined during in vitro experiments in the MR environment. Heating of guidewires to>70 degrees was reported during in vitro experiments. Our own in vivo experiments using commercially available metallic guidewires observed heating to up to 35 degrees at the guidewire tip, despite the cooling effect of blood flowing around the guidewire. Moreover, we saw the development of sparks at the end of the guidewire if it was bent inside of the MR scanner and touched to the animal. But it was not possible to reliably repeat these heating results. We conclude that longer metallic parts have to be avoided inside the MR scanner to guarantee patient safety. In order to exploit more sophisticated technologies such as active tip tracking, solutions without the need for conducting wires have to be further developed before interventional MR can safely move into the clinical setting.

Animals↗

Evaluation of catheter loops in central venous port systems.

OBJECTIVES: We sought to evaluate the cause for catheter loops of central venous ports. MATERIAL AND METHODS: A total of 241 patients who received a central venous port via subclavian vein access were included in this retrospective study. Eighty of these patients had undergone a computed tomography of the chest, allowing retrospective evaluation of the course of central venous catheters. Complications were evaluated by review of the clinical data charts. RESULTS: In 49 patients, the catheter penetrated only the major pectoralis muscle. Only one of these patients (2.0%) showed a loop. In 31 cases, the catheter went through both the major and minor pectoralis muscle, and in 26 of these patients (83.9%), a loop was seen. Complications after port implantation were catheter occlusion (n = 2), pneumothorax (n = 2), thrombosis (n = 2), infection (n = 1), and catheter dislocation (n = 1). CONCLUSIONS: The loop of catheter of central venous ports is caused by catheter penetration through pectoralis major and minor.

Adult↗

MRI of coronary vessel walls using radial k-space sampling and steady-state free precession imaging.

OBJECTIVE: The objective of our study was to investigate the impact of radial k-space sampling and steady-state free precession (SSFP) imaging on image quality in MRI of coronary vessel walls. SUBJECTS AND METHODS: Eleven subjects were examined on a 1.5-T MR system using three high-resolution navigator-gated and cardiac-triggered 3D black blood sequences (cartesian gradient-echo [GRE], radial GRE, and radial SSFP) with identical spatial resolution (0.9 x 0.9 x 2.4 mm3). The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and motion artifacts were analyzed. RESULTS: The mean SNR and CNR of the coronary vessel wall were improved using radial imaging and were best using radial k-space sampling combined with SSFP imaging. Vessel border definition was similar for all three sequences. Radial k-space sampling was found to be less sensitive to motion. Consistently good image quality was seen with the radial GRE sequence. CONCLUSION: Radial k-space sampling in MRI of coronary vessel walls resulted in fewer motion artifacts and improved SNR and CNR. The use of SSFP imaging, however, did not result in improved coronary vessel wall visualization.

Adult↗

Dynamic multi-section CT imaging in acute myocardial infarction: preliminary animal experience.

To evaluate the feasibility of myocardial first-pass perfusion imaging with multidetector CT (MDCT). In five pigs, myocardial infarction was induced by permanent balloon occlusion of the left anterior descending coronary artery. Dynamic contrast-enhanced MDCT (12x1.5 mm, 120 kV, 30 mAs, 64 acquisitions, 40 ml iopromide 370@4 ml/s) and contrast-enhanced first-pass perfusion magnetic resonance (MR) imaging (TR 7.7 ms/TE 2.6 ms, 64 acquisitions, 0.05 mmol/kg Gd-DTPA) were performed. Finally, the animals were sacrificed, and the heart was excised and stained with triphenyltetrazolin-chloride (TTC). Maximum signal intensity (SImax), contrast material arrival time (CAT), wash-in time (Tmax) and slope were calculated from time-density/signal-intensity curves. The area of myocardial hypoperfusion was measured as the percentage of the left-ventricular area (%LV). Parameters were compared using Bland-Altman plots and Student's t-tests. The hypoperfused area on MDCT was 19.3+/-4.5%LV (MR imaging 17.2+/-4.0%LV). The mean size of infarction was 18.7+/-5.7%LV with TTC. Semiquantitative analysis of MR imaging and MDCT for SImax, Tmax and slope showed significant differences between normal and infarcted myocardium (P<0.05). No significant differences were found for CAT. MDCT and MR imaging both allowed for the differentiation of hypoperfused and normal myocardium. Results given in absolute values differed significantly between both imaging modalities (P<0.05). MDCT has the potential for visual and semiquantitative assessment of first-pass myocardial perfusion.

Animals↗

Dehiscence of the superior and/or posterior semicircular canal: delineation on T2-weighted axial three-dimensional turbo spin-echo images, maximum intensity projections and volume-rendered images.

The purpose of this study was to compare the ability of T2-weighted three-dimensional turbo spin-echo (TSE) images, maximum intensity projections and three-dimensional volume-rendered images for delineation of semicircular canal dehiscence. In 26 patients with dehiscence of the superior and/or posterior semicircular canal and 26 control patients, TSE images were obtained with two different resolutions and maximum intensity projection (MIP) and 3D volume-rendered images reconstructed. All images were evaluated by two radiologists in consensus regarding the visualization of anatomical structures and dehiscence of the semicircular canals. Computed tomography was used to confirm or exclude dehiscence. Dehiscence of the semicircular canals was delineated on axial MR images and on 3D volume-rendered images, but not on MIP images. The number of false positive cases was reduced from 3 to 0 with an increase in matrix, rendering results similar to those obtained with CT. Dehiscence of the semicircular canals can be assessed on high resolution MR images. Volume-rendered 3D images allow for immediate perception of the location of defects in semicircular canal dehiscence. These images may facilitate understanding of the extent and location of the defects.

Adolescent↗

Molecular magnetic resonance imaging of atrial clots in a swine model.

BACKGROUND: The detection and differentiation of intracardiac masses is still challenging and may include neoplasms and thrombi. The aim of this study was the investigation of a targeted, fibrin-specific contrast agent (EP-2104R) for molecular targeted magnetic resonance imaging (MRI) of left atrial clots. METHODS AND RESULTS: Chronic human thrombi were surgically implanted in the left atrial appendage of 5 swine. Molecular MRI was performed with a navigator-gated, free-breathing, cardiac-triggered 3D inversion-recovery, black-blood, gradient-echo sequence before and after systemic administration of 4 micromol/kg EP-2104R. MR images were analyzed by 2 investigators, and the contrast-to-noise ratio was calculated. Location of clots was confirmed by autopsy, and the gadolinium concentration in the clots was assessed. Before contrast agent administration, thrombi were not visible on black-blood MR images. After contrast administration, all atrial clots (n=5) were selectively visualized as white spots with a high contrast-to-noise ratio (clot/blood, 29.7+/-8.0). The gadolinium concentration in the clots averaged 74+/-45 micromol/L. CONCLUSIONS: The fibrin-specific MR contrast agent EP-2104R allows for selective and high-contrast visualization of left atrial clots by means of molecular targeted MRI.

Animals↗

Assessment of myocardial viability in reperfused acute myocardial infarction using 16-slice computed tomography in comparison to magnetic resonance imaging.

OBJECTIVES: The aim of this study was to examine if contrast-enhanced multislice spiral computed tomography (MSCT) is comparable to contrast-enhanced magnetic resonance imaging (MRI) for depiction of acute myocardial infarction (MI). BACKGROUND: Delayed-enhancement MRI of MI is well established, but there are no clinical reports about MSCT for this indication. Early perfusion deficit on MSCT has been reported to correlate with the presence of MI. METHODS: A total of 28 consecutive patients (23 men; 55.9 +/- 11.4 years) with reperfused MI underwent contrast-enhanced cardiac 16-slice MSCT. Images were acquired in the arterial phase and the late phase 15 min after administration of 120 ml contrast material. Within 5 days, patients underwent MRI after administration of 0.2 mmol Gd-dimeglumine/kg/bodyweight. All examinations were completed within two weeks after MI. The area of MI was compared between the different imaging techniques using Bland-Altman method and multivariate analysis. Agreement of the contrast enhancement patterns was evaluated with a weighted kappa test. RESULTS: Mean infarct size on MRI was 31.2 +/- 22.5% per slice compared with 33.3 +/- 23.8% per slice for late-enhancement MSCT and 24.5 +/- 18.3% per slice for early-perfusion-deficit MSCT. Bland-Altman data showed a good agreement between late-enhancement MRI and late-enhancement MSCT. Contrast enhancement patterns demonstrated an excellent agreement between late-enhancement MRI and late-enhancement MSCT (kappa = 0.878). The results were worse comparing MRI and early-phase MSCT (kappa = 0.635). CONCLUSIONS: Multislice spiral computed tomography allows for the assessment of acute MI. Late-enhancement MSCT appears to be as reliable as delayed contrast-enhanced MRI in assessing infarct size and myocardial viability in acute MI.

Adult↗

Acute myocardial infarction: assessment of left ventricular function with 16-detector row spiral CT versus MR imaging--study in pigs.

PURPOSE: To assess global left ventricular (LV) function and regional wall motion with retrospective electrocardiographically gated 16-detector row computed tomography (CT) in comparison with magnetic resonance (MR) imaging. MATERIALS AND METHODS: In 15 pigs (mean weight, 53.9 kg +/- 9.5 [standard deviation]), acute myocardial infarction was induced with balloon occlusion of the left anterior descending coronary artery after approval was obtained from the committee on animal affairs. Thereafter, multi-detector row CT and MR imaging were performed with standardized examination protocols. From manually drawn endocardial and epicardial contours, LV volumes, including mean ejection fraction, peak filling rate (PFR), peak ejection rate (PER), time to PER, and time from end systole to PFR, were calculated. Regional wall motion was assessed from cine loops with a 16-segment model of the left ventricle. LV function was analyzed by using Bland-Altman plots, Student t test, and Pearson correlation coefficient. Regional wall motion scores were compared with weighted kappa statistic. RESULTS: LV volumes determined with multi-detector row CT correlated well with MR imaging results, with an ejection fraction of 46.1% +/- 6.5 for multi-detector row CT and 46.8% +/- 5.9 for MR imaging (r = 0.97). PER, PFR, time to PER, and time from end systole to PFR showed a wide range of scattering and significant differences between multi-detector row CT and MR imaging for PER and time from end systole to PFR (P < .05). Regional wall motion scores showed a very high level of agreement with a kappa value of 0.88. CONCLUSION: Although 16-detector row CT allows reliable assessment of LV volumes and regional wall motion at rest, it is not suited for assessment of all functional parameters.

Animals↗

Molecular magnetic resonance imaging of pulmonary emboli with a fibrin-specific contrast agent.

RATIONALE AND OBJECTIVES: The detection of pulmonary embolism is still challenging due to the often nonspecific clinical findings. The aim of this study was to investigate the potential of molecular targeted magnetic resonance imaging (MRI) of pulmonary emboli using low-dose application of a fibrin-specific contrast agent (EP-2104R; Epix Pharmaceuticals, Cambridge, MA). METHODS: Fresh clots from human blood were engineered ex vivo and delivered in the lungs of 11 swine. Subsequently, a T1-weighted breath-hold three-dimensional gradient-echo sequence was performed before as well as 5 minutes, 1 hour, and 2 hours after systemic administration of 7.5 (n = 5) or 4 (n = 5) micromol/kg EP-2104R. One swine that did not receive any contrast agent served as a control. MR images were analyzed by two investigators and contrast-to-noise ratio between the thrombus and the surrounding tissue (blood pool and lung parenchyma) was assessed. Localization of thrombi was compared with 16-row multislice computed tomography. Finally, the animals were killed and thrombi were removed for assessment of gadolinium concentration. MAIN RESULTS: Before contrast media application, thrombi were not visible on MR images. At 1 and 2 hours after contrast media injection, pulmonary emboli were selectively visualized with high-signal intensity foci, independent of the dosage used. A high gadolinium concentration in thrombi was found after both dosages (83 +/- 41 microM for 4 micromol/kg and 130 +/- 57microM for 7.5 micromol/kg), resulting in a similar high contrast-to-noise ratio on MR images (between 11 and 13). CONCLUSION: Systemic low-dose application of EP-2104R allows for selective molecular MRI of fresh pulmonary thromboembolism in a swine model.

Animals↗

Is there a need for contrast-enhanced T1-weighted MRI of the spine after inconspicuous short tau inversion recovery imaging?

To assess the use of contrast-enhanced T1-weighted images in comparison with short tau inversion recovery (STIR) images for the detection of vertebral bone marrow abnormalities. A total of 201 vertebral magnetic resonance (MR) examinations were included in a prospective trial. Examinations were performed on a 0.5-T MR scanner. The examination protocol included STIR, T2-weighted turbo spin-echo and T1-weighted spin-echo images before and after administration of gadopentetate dimeglumine. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of STIR images were calculated. In the case of abnormal STIR images the additional information from contrast-enhanced images was evaluated using Fisher's exact test. The value of the combined evaluation of STIR and contrast-enhanced T1-weighted images was compared with that of the combined assessment of T2-weighted and contrast-enhanced T1-weighted images. The PPV and the NPV of STIR images for detection of vertebral bone marrow abnormalities were 99.3 and 95.9%. In the case of normal STIR images no relevant additional information was found with contrast-enhanced T1-weighted images, while in the case of abnormal STIR images significant supplementary information was obtained. There was no difference in the diagnostic value when comparing combined assessment of STIR and contrast-enhanced T1-weighted images with combined evaluation of T2-weighted and contrast-enhanced T1-weighted images. Normal STIR images allow contrast-enhanced T1-weighted images for detection of bone marrow abnormalities to be omitted, whereas further imaging is needed in case of abnormal STIR images.

Adult↗

Molecular magnetic resonance imaging of coronary thrombosis and pulmonary emboli with a novel fibrin-targeted contrast agent.

BACKGROUND: The differential diagnosis of acute chest pain is challenging, especially in patients with normal ECG findings, and may include coronary thrombosis or pulmonary emboli. The aim of this study was to investigate the novel fibrin-specific contrast agent EP-2104R for molecular targeted MR imaging of coronary thrombosis and pulmonary emboli. METHODS AND RESULTS: Fresh clots were engineered ex vivo from human blood and delivered in the lungs and coronary arteries of 7 swine. Subsequent molecular MR imaging was performed with a navigator-gated free-breathing and cardiac-triggered 3D inversion-recovery black-blood gradient-echo sequence before and after systemic administration of 7.5 micromol/kg EP-2104R. Two swine served as the control group. MR images were analyzed by 2 investigators, and contrast-to-noise ratio and gadolinium concentration in the clots were assessed. Before contrast media application, no thrombi were visible. After contrast administration, all 32 pulmonary emboli, 3 emboli in the right heart, and 5 coronary thrombi were selectively visualized as white spots with a mean contrast-to-noise ratio of 32+/-19. The average gadolinium concentration from all 3 types of thrombi was 144+/-79 micromol/L. CONCLUSIONS: Molecular MR imaging with the fibrin-targeted contrast-agent EP-2104R allows selective visualization of acute coronary, cardiac, and pulmonary thrombi.

Angiography↗

Artifact-free coronary magnetic resonance angiography and coronary vessel wall imaging in the presence of a new, metallic, coronary magnetic resonance imaging stent.

BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.

Animals↗

Free-breathing renal magnetic resonance angiography with steady-state free-precession and slab-selective spin inversion combined with radial k-space sampling and water-selective excitation.

The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning.

Adult↗