PubMed Health⌕ Search

Biomedical subjects

Arnold G Schuring

Publications and source records attributed to Arnold G Schuring.

7 recordsLinked to original sources

Comparison of titanium and Robinson stainless steel stapes piston prostheses.

OBJECTIVE: Although stainless steel stapes prostheses have generally been considered magnetic resonance imaging safe, there is concern that this may change with the development of more powerful imaging systems. The objective of the study was to determine whether a titanium piston stapes prosthesis would be audiometrically and surgically equivalent to a Robinson stainless steel piston for stapedectomy. STUDY DESIGN: Retrospective chart review. SETTING: Private otology practice. PATIENTS: In all, 50 patients underwent stapedectomy with a Gyrus titanium piston prosthesis. These patients were matched on the basis of age and preoperative bone-conduction scores with patients who underwent stapedectomy with a Robinson stainless steel piston prosthesis. MAIN OUTCOME MEASURES: Audiometric results are analyzed, and surgical complications noted. RESULTS: There was no significant difference between groups in hearing improvement or postoperative air-bone gap. The mean four-frequency hearing improvement was 27.7 dB for the stainless steel group and 27.8 dB for the titanium group. The mean postoperative air-bone gap was 2.65 dB for the stainless steel group and 2.60 for the titanium group. Neither group had a surgical complication. CONCLUSION: The titanium stapes prosthesis is a good alternative to a stainless steel prosthesis.

Adult↗

Does pregnancy affect otosclerosis?

OBJECTIVE: To evaluate the effect of pregnancy on the hearing of women with otosclerosis. STUDY DESIGN: A retrospective study of women who had undergone stapedectomy. The women were equally divided into two groups: one group with children and a control group without children. Air and bone conduction, as well as discrimination, were measured before and after stapedectomy in both groups. PATIENTS: Ninety-four women (47 with children and 47 without) were evaluated. Because many of the women had bilateral otosclerosis, the total number of ears studied was 128. RESULTS: Mean pure tone air and bone conduction thresholds were not worse in women with children versus those women without children. In fact, mean pre- and postoperative pure tone air and bone conduction thresholds from 500 Hz through 4,000 Hz in women with children were slightly but significantly better than women without children. There was no difference in discrimination scores between groups. Within the group with children, no significant correlation was found between number of children and hearing loss. Also, no correlation was found between breastfeeding and the amount of hearing loss. CONCLUSION: We found no adverse effect on hearing in otosclerotic women who had children compared with women without children. Even with increasing numbers of pregnancies, no deleterious impact was noted. Air conduction, bone conduction, and discrimination were not worse in women with children versus childless women. No significant correlation was found between the number of children and hearing loss, and neither did breastfeeding affect the amount of hearing loss.

Adult↗

Stapedectomy in patients with a prolapsed facial nerve.

OBJECTIVE: We evaluated the method of stapedectomy and hearing results in patients who have 50% or more of the footplate covered by a prolapsed facial nerve. STUDY DESIGN: We conducted a retrospective review of 1497 primary stapedectomies performed between 1986 and 1995. METHODS: Twenty-eight patients had 50% or more of the oval window covered by a prolapsed facial nerve. Twenty-three patients in this group had adequate follow-up and their hearing results were compared with a matched control group of 50 patients with normal facial nerve anatomy. Also, facial nerve outcomes and any other complications are reported. RESULTS: In the patient group with facial nerve prolapse, closure of the postoperative air-bone gap to 10 dB or less was achieved in 19 of 23 (83%) ears and 16 of 20 (80%) ears at 6 months and 1 year, respectively. At 6 months and 1 year, the postoperative air-bone gap in 47 of 50 (94%) ears and 40 of 43 (93%) ears in the control group had closed to 10 dB or less. The average postoperative air-bone gap was 5.1 dB at 6 months and 6.8 dB at 1 year for the group with facial nerve prolapse. In comparison, the average postoperative air-bone gap in the control group was 3.5 dB and 3.9 dB, respectively. The difference in the hearing results for the 2 groups was not statistically significant. CONCLUSION: When the facial nerve covered at least 50% of the oval window, the poststapedectomy hearing results at 6 months and 1 year were similar to those of a matched control group of stapedectomy patients with a normal facial nerve course. There were no short- or long-term facial nerve complications in either group. In light of these results, we conclude that stapedectomy in patients with significant facial nerve prolapse can be performed safely with good hearing results.

Audiometry↗

Tympano-ossiculoplasty utilizing the Spiggle and Theis titanium total ossicular replacement prosthesis.

OBJECTIVE: Since 1993, titanium prostheses have been used in Europe as a biocompatible implant for ossicular reconstruction. More recently, the titanium ossicular prosthesis has become more widely available in the United States as a newer means of surgical restoration of hearing. We will review the hearing results of patients who have undergone tympano-ossiculoplasty using a titanium total ossicular replacement prosthesis (TOP). We will compare these results to our previously published results using the porous polyethylene TOP. METHODS: Retrospective review in a tertiary otologic practice. RESULTS: Eighteen patients underwent tympano-ossiculoplasty with a titanium TOP. Among these patients, 10 cases involved revision of a previously placed ossicular prosthesis. Hearing results showed that 16 of 18 patients (89%) had closure of the postoperative air-bone gap to within 20 dB, and the average air-bone gap improvement was 23 dB. The average follow-up time was 8 months (range, 2-21 months). The results of this initial evaluation compare favorably with the results that we obtained using a porous polyethylene TOP in which 67% of 133 patients closed the air-bone gap to within 20 dB. CONCLUSION: We have recently begun using the titanium TOP, which has resulted in improved postoperative hearing when compared with the porous polyethylene TOP. In the future, longer follow-up and increased patient numbers will strengthen our conclusions.

Adolescent↗

Twenty-year review of revision stapedectomy.

OBJECTIVE: To evaluate surgical findings and techniques, patient management techniques, and audiometric results of 522 revision stapedectomies. STUDY DESIGN: Retrospective chart review. SETTING: Tertiary otologic referral center. PATIENTS: A total of 522 revision stapedectomies over a 20-year period in Warren, Ohio, and Israel. The audiologic criterion for revision was an air-bone gap greater than 20 dB over the three-frequency range 0.5 to 2 kHz. RESULTS: Of the 522 revision cases, a total of 483 patients were operated on to improve hearing. The remainder of the patients were operated on for various other noted reasons. Closure of the air-bone gap to within 10 dB was achieved in 71% of patients (343 of 483). The mean pure-tone average improvement was 17.8 dB, with an average postoperative air-bone gap of 7.3 dB. The most common surgical findings were prosthesis malfunction at the oval window, incus, or both (58%). Since beginning the use of the Argon laser for surgical problems, the success rate has increased to 80%. A subgroup of 35 Argon laser revision stapedectomies resulted in a larger hearing gain (25.2 dB) and 91.4% closure of the air-bone gap to less than 10 dB. CONCLUSIONS: More than 70% of revision stapedectomy cases for hearing improvement have had successful closure of their air-bone gap. Since the introduction of the laser 5 years ago, the success rate has increased to 80%. In those specific cases where the laser was required, the success rate increased to 91.4%. Regardless of the revision technique, hearing results were the least successful when the incus could not be used for reconstruction.

Animals↗

Stapedectomy revision in elderly patients.

OBJECTIVE: the objective was to determine the effectiveness of stapedectomy revision in patients 65 years of age or older. Although stapedectomy revision has been discussed in the literature, as well as primary stapedectomy surgery for elderly patients, we could find no study dedicated to stapedectomy revision in elderly patients. STUDY DESIGN: Retrospective. METHODS: One hundred twenty patients 65 years of age or older who had a stapedectomy revision between 1980 and 2001 were included. A randomly selected group of 120 patients younger than 65 years of age who had stapedectomy revision were included for comparison. Audiometric results were compared for the two groups. Surgical findings for each group are also discussed. RESULTS: The mean pure-tone average hearing improvement for each group was 17.6 dB. The success rate was 70.8% for the elderly group and 67.6% for the younger group. Surgical findings during revision in elderly patients were generally the same as those found for younger patients. CONCLUSION: Advanced age should not be seen as a contraindication to stapedectomy revision.

Age Factors↗

Promontory drilling in stapedectomy.

OBJECTIVE: Evaluate in stapedectomy the clinical outcome and audiometric results (particularly bone conduction) of drilling the promontory because of a narrow oval window niche. STUDY DESIGN: Retrospective. SETTING: Tertiary referral center, private otology practice. PATIENTS: Twenty-five stapedectomy patients requiring promontory drilling who had surgery between 1995 and 2000. METHOD: A total of 25 patients were evaluated with a minimum 6-month follow-up. Only patients who required promontory drilling and who had complete preoperative and postoperative audiometric testing including bone conduction were included. Promontory drilling was performed with a skeeter drill to thin the promontory. Twenty-five stapedectomy patients who did not undergo promontory drilling were randomly selected from this same period as a comparison group. RESULTS: In addition to the narrow oval window niche, associated anatomical findings were facial nerve overhang in five patients and an obliterated footplate in three patients. Ninety-six percent of cases were successful (<10 dB postoperative air-bone gap). The one unsuccessful case was a strut over the mobile footplate that was later successfully revised. No patients suffered from intraoperative or postoperative tinnitus or vertigo. The mean 4-frequency (500-4,000 Hz) pure-tone average revealed slight improvement in bone conduction postoperatively. CONCLUSION: Drilling of the promontory in stapedectomy is required in only a small percentage of cases. Although audiometric results indicated the possibility of a slight amount of acoustic trauma from the drilling, the effect on hearing was minimal and not considered a contraindication to this procedure.

Adult↗