Results of four-corner arthrodesis using dorsal circular plate fixation.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Arnold-Peter C Weiss.
Explore the source record for details and available documents.
Radial head fractures are a particularly common yet challenging problem facing orthopedic surgeons today. Over the years multiple treatment modalities have been used including conservative management, open reduction and internal fixation, head excision, and radial head arthroplasty. The clinical outcome studies of metallic radial head arthroplasty systems indicate that head replacement is a reasonable option to offer patients with comminuted radial head fractures and complex elbow trauma. Overall the results for this procedure are quite encouraging and appear durable given the severity of the elbow injuries treated with radial head arthroplasty. This article discusses the history, classification, and treatments of radial head fractures. A description of the stabilizing structures of the elbow as they relate to radial head fractures also is included. Surgical considerations that relate to radial head arthroplasty are detailed and encompass arthroplasty indications, surgical technique, postoperative rehabilitation, and complications. Finally the arthroplasty outcomes literature and a review of current implant options also are discussed.
Glomus tumors are rare vascular tumors that are found most commonly in the hand. Although the tumors are benign, they can cause intense focal pain. Patients often go undiagnosed or misdiagnosed for many years because the tumors are small, usually not palpable, and have varying presentations. A combination of magnetic resonance imaging and clinical examination is used to support the diagnosis. Surgical excision normally provides complete pain relief. An awareness of the diagnosis is critical to preventing an unnecessary delay in treatment.
The scaphoid plays a critical role in maintain-ing normal carpal kinematics. SLAC and SNAC wrist arthritis demonstrate the ramifications ofscaphoid pathology on wrist biomechanics. In the past, symptomatic SLAC or SNAC pathology spelled total wrist arthrodesis. Over the past 20 years there has been a movement toward limited wrist arthrodesis in the treatment of SLAC/SNAC wrists. In the long-term follow-up of four-corner fusions, patient satisfaction is high, patients are able to return to their previous vocation, and wrist function averages 60%-70% of the contralateral wrist. The Spider plate is a recent advancement in the four-corner fusion armamentarium that has thus far shown great promise in respect to fusion rates (100% in the first documented series [36]),functional range of motion, intercarpal stability[37], and patient satisfaction.
PURPOSE: The surgical treatment of the rheumatoid wrist is key in managing the affected hand. Wrist fusion is often the treatment of choice in cases of severe destruction and deformation although most patients would prefer a motion-preserving procedure. The implantation of a wrist prosthesis might be an alternative to partial arthrodesis for selected cases. In this series we analyzed the long-term results (minimum follow-up period, 10 y) of the Swanson silicone spacer for the wrist in patients with rheumatoid arthritis. METHODS: Sixteen patients with rheumatoid arthritis with 18 silicone spacers for the wrists were reviewed after a minimum follow-up period of 10 years (average, 15 y). Subjective evaluation, clinical examination, and radiographic analysis were included. An additional 9 patients (9 wrists) were interviewed by telephone. RESULTS: In 12 of the patients the subjective result was good or very good, mostly because of adequate pain relief. The average range of motion for flexion (average, 28 degrees )/extension (average, 15 degrees ) was 43 degrees with a wide variation within the series. Radiologically all wrists had diminished residual carpal height at follow-up evaluation and 9 of the wrists had evidence of osteolysis and foreign-body granuloma. The initial good correction of the ulnar translation of the wrist was lost partially in the follow-up period (1.1 vs 4.0 mm). Three of the patients needed surgical revision within the follow-up period; all were converted to wrist fusion. CONCLUSIONS: These long-term results suggest that the silicone wrist spacer still may be considered as an alternative to wrist fusion or more complex wrist joint prostheses in patients with rheumatoid arthritis, especially in severe cases and in patients with low demands. In the long term osteolysis caused by foreign-body granulation is to be expected and has to be considered.
BACKGROUND: Wrist motion is dependent on the complex articulations of the scaphoid and lunate at the radiocarpal joint. However, much of what is known about the radiocarpal joint is limited to the anatomically defined motions of flexion, extension, radial deviation, and ulnar deviation. The purpose of the present study was to determine the three-dimensional in vivo kinematics of the scaphoid and lunate throughout the entire range of wrist motion, with special focus on the dart thrower's wrist motion, from radial extension to ulnar flexion. METHODS: The three-dimensional kinematics of the capitate, scaphoid, and lunate were calculated from serial computed tomography scans of both wrists of fourteen healthy male subjects (average age, 25.6 years; range, twenty-two to thirty-four years) and fourteen healthy female subjects (average age, 23.6 years; range, twenty-one to twenty-eight years), which yielded data on a total of 504 distinct wrist positions. RESULTS: The scaphoid and lunate primarily flexed or extended in all directions of wrist motion, and their rotation varied linearly with the direction of wrist motion (R2= 0.90 and 0.82, respectively). Scaphoid and lunate motion was significantly less along the path of the dart thrower's motion than in any other direction of wrist motion (p < 0.01 for both carpal bones). The scaphoid and lunate translated radially (2 to 4 mm) when extended, but they did not translate appreciably when flexed. CONCLUSIONS: The dart thrower's path defined the transition between flexion and extension rotation of the scaphoid and lunate, and it identified wrist positions at which scaphoid and lunate motion approached zero. These findings indicate that this path of wrist motion confers a unique degree of radiocarpal stability and suggests that this direction, rather than the anatomical directions of wrist flexion-extension and radioulnar deviation, is the primary functional direction of the radiocarpal joint.
PURPOSE: This study was performed to compare metacarpophalangeal (MCP) joint mechanics after arthroplasty with 3 currently available silicone implants and to determine how postarthroplasty mechanics compares with the mechanics of the intact joint. METHODS: Planar 2-dimensional kinematic analysis was performed using digitized radiographs on 10 isolated fingers harvested from 5 fresh-frozen human cadavers. Radiopaque markers were affixed to the metacarpals and proximal phalanges, sewn to the flexor and extensor tendons, and placed into the stems and hinges of the implants. Each finger was tested intact, and after MCP joint replacement with 3 implants (Swanson [Wright Medical, Memphis, TN], Avanta [Avanta Orthopaedics, San Diego, CA], and NeuFlex [DePuy Orthopaedics, Warsaw, IN]). The fingers were secured to the test fixture and the flexor digitorum profundus flexor and extensor tendons were loaded with physiologic weights. Lateral radiographs were taken at approximately 10 degrees intervals and were digitized on a high-resolution scanner. Instantaneous center of rotation (ICR), tendon excursion, and tendon moment arm were calculated. Statistical analysis was performed using repeated measures one-way analysis of variance and Dunnett post tests. RESULTS: The ICRs of the intact and implanted MCPs did not follow a smooth path. The variability of the ICRs of the intact MCP joints was 2.1 +/- 0.8 mm. The variations in the Avanta and DePuy implants were similar (3.1 +/- 1.0 mm and 3.5 +/- 1.5 mm, respectively), whereas the Swanson implant was higher (4.9 +/- 1.7 mm). Implant pistoning was most pronounced with the Swanson implant, which moved 2.40 +/- 0.97 mm over the full range of motion. The Avanta and DePuy implants pistoned significantly less than the Swanson implant (1.05 +/- 0.45 mm and 0.69 +/- 0.31 mm, respectively). Flexor tendon excursion was greater for the intact joint when compared with all 3 implants while extensor tendon excursion was similar for all. Flexor tendon moment arm was similar for the intact joint and the Avanta and NeuFlex implants whereas the Swanson implant was reduced significantly; extensor tendon moment arms were similar for all. CONCLUSIONS: The ICR of the NeuFlex implant most closely matched that of the intact MCP joint. The Swanson implant had greater pistoning and dorsal-volar translation when compared with the intact joint and the Avanta and NeuFlex implants. The block-hinge type design of the Avanta and NeuFlex implants improved tendon moment arm overall when compared with the Swanson, likely imparting greater functional ability for finger motion. Overall the NeuFlex implant most closely matched the ICR, tendon excursion, and moment arm when compared with the intact native MCP joint.
Internet use is increasing and its applications to medicine and patient information are widening daily. Previous studies have focused on the quality and quantity of medical information on the Internet. The current study focuses on a population of 120 new patients presenting to a hand surgery practice. A questionnaire was used to analyse patterns of Internet access, use of the Internet to look up personal symptoms, and patients' opinions on the use of electronic mail by office staff. Results showed that approximately 90% of the group had some form of Internet access, with a significant age-related decrease in Internet access. Only 17% used the Internet to look up their symptoms, but this group was more likely to correctly match their self-diagnosis to the surgeon's diagnosis. On average, 65% of the study group favoured the use of electronic mail for office staff's communications with patients.
Osteoarthritis of the wrist is one of the most common conditions encountered by the orthopaedic surgeon and requires careful analysis and specific indications and rationale for appropriate treatment. Radiographic analysis and surgical approaches for reconstruction of the wrist consist of technical caveats that will improve outcome, including limited wrist fusions, proximal row carpectomy, and total wrist fusion.
The controversy has been considerable regarding the incidence of familial carpal tunnel syndrome. Of particular interest is the relationship between bilateral disease and familial incidence. In this study, we compare the incidence of familial carpal tunnel syndrome in patients with the syndrome in one, both, or neither hands. We report a significantly greater incidence of familial carpal tunnel syndrome in those patients with bilateral disease than in a similar population of patients with either unilateral disease or no carpal tunnel syndrome. These results may imply inheritability of variations in the size of the tunnel or its contents, which would manifest themselves bilaterally and may cause a predisposition for developing the syndrome. Being aware of the propensity for bilateral disease may improve our ability to prevent and treat the disease.
This article discusses scapholunocapitate arthrodesis utilizing the mini-spider plate focusing on a procedure review, surgical technique, and clinical preliminary results.
Mini-open carpal tunnel release has been the focus of recent attention for surgical decompression of carpal tunnel syndrome. Other techniques such as standard open carpal tunnel release and endoscopic release have been well established, and outcomes, complications and results for these operations have been published widely. Our study uses the validated Levine Katz questionnaire for carpal tunnel syndrome to measure patient subjective outcomes at one year follow-up after mini-open carpal tunnel release. Thirty-four consecutive hands were enrolled prospectively with preoperative and postoperative questionnaires. Mean symptom severity scores per question improved from 2.8 to 1.3 and mean function severity scores per question improved from 2.6 to 1.3. Comparing our data to the historical cohort of Levine et al., there was a statistically significant improvement in postoperative outcomes in our population (p < 0.0001).
How malunion of the distal radius affects the kinematics of the distal radioulnar joint in vivo was evaluated. A novel computed tomography image-based technique was used to quantify radioulnar motion in both wrists of 9 patients who had unilateral malunited distal radius fractures. In the injured wrists dorsal angulation averaged 21 degrees +/- 6 degrees, radial inclination averaged 18 degrees +/- 5 degrees, and radial shortening averaged 21 +/- 3 mm. Clinically, the average range of motion of the injured wrists was 75 degrees +/- 25 degrees pronation and 73 degrees +/- 23 degrees supination. Kinematics of the radius during pronation and supination in the malunited forearms was indistinguishable from that in the uninjured forearms. In both the axis of rotation of the radius passed through the center of the ulnar head, although it shifted slightly ulnar and volar in supination and radial and dorsal during pronation. In contrast to previous in vitro biomechanical findings, there was no dorsovolar radial translation at the extremes of pronation or supination and no translation of the radius along the rotation axis. Soft tissues may play a larger role in limiting function than previously appreciated, and treatment may require correction of altered soft tissue structures as well as any abnormal bone anatomy.
Explore the source record for details and available documents.