In vitro controllability of the MagScrew total artificial heart system.

The purpose of this study was to evaluate the in vitro responses to preload and afterload of our total artificial heart (TAH), the MagScrew TAH. The TAH consists of two blood pumps and a control logic, developed at the Cleveland Clinic, OH, and the MagScrew actuator and its electronic control system, developed by Foster-Miller Technologies, Inc., Albany, NY. Tests were performed on a mock circulatory loop, using water as a test fluid. Preload sensitivity of the Mag-Screw TAH demonstrated a Frank-Starling response to preload in automatic mode. A peak flow of 10 L/min was obtained, with a left atrial pressure of 13 mm Hg. The relationship between right atrial pressure and left atrial pressure was well balanced when tested with a left bronchial shunt flow of 5% and a range of pulmonary artery and aortic pressures. With respect to afterload response, the left pump showed a relatively low sensitivity, which allowed the pump to maintain perfusion over a wide range of aortic pressures. The right pump, on the other hand, was much more sensitive to pulmonary artery pressure, which provided a measure of protection against pulmonary congestion. The very effective physiologic response of the MagScrew TAH is believed to result from employment of a left master, alternating ejection control logic, high inherent sensitivity of the blood pumps to atrial pressure, a lower effective stroke volume for the right pump, and a scaling of right side motor ejection voltage to 80% of that used for the left side ejection.

Aorta↗

MagScrew TAH: an update.

The MagScrew Total Artificial Heart (TAH) system is the result of a close collaboration among the Cleveland Clinic Foundation, Foster Miller Technologies, Wilson Greatbatch Ltd, and Whalen Biomedical Inc. The system components are the thoracic blood pumping unit with attached compliance chamber and refill port, implantable electronic control unit, implantable battery pack, transcutaneous energy transmission system, external battery pack, and a telemetry system for communication with the electronic control unit. System in vitro tests are underway for system characterization and durability demonstration, whereas in vivo tests were conducted to evaluate system performance and biocompatibility under physiologic conditions. The passively filling pump uses a left master alternate left and right ejection control mode and has a Starling law-like response to venous pressure. The in vitro tests documented excellent hydraulic pump performance with high device output of over 9 l/min at left atrial pressures below 12 mm Hg. Atrial balance was well maintained under all test conditions. The in vivo tests demonstrated good biocompatibility without use of anticoagulant therapy. Experimental durations have ranged between 0 and 92 days. Postexplant evaluation of tissue samples did not reveal any sign of thromboembolic events or tissue damage due to device operation.

Animals↗