PubMed Health⌕ Search

Biomedical subjects

Arthur F Gmitro

Publications and source records attributed to Arthur F Gmitro.

9 recordsLinked to original sources

Acid-mediated tumor invasion: a multidisciplinary study.

The acid-mediated tumor invasion hypothesis proposes altered glucose metabolism and increased glucose uptake, observed in the vast majority of clinical cancers by fluorodeoxyglucose-positron emission tomography, are critical for development of the invasive phenotype. In this model, increased acid production due to altered glucose metabolism serves as a key intermediate by producing H(+) flow along concentration gradients into adjacent normal tissue. This chronic exposure of peritumoral normal tissue to an acidic microenvironment produces toxicity by: (a) normal cell death caused by the collapse of the transmembrane H(+) gradient inducing necrosis or apoptosis and (b) extracellular matrix degradation through the release of cathepsin B and other proteolytic enzymes. Tumor cells evolve resistance to acid-induced toxicity during carcinogenesis, allowing them to survive and proliferate in low pH microenvironments. This permits them to invade the damaged adjacent normal tissue despite the acid gradients. Here, we describe theoretical and empirical evidence for acid-mediated invasion. In silico simulations using mathematical models provide testable predictions concerning the morphology and cellular and extracellular dynamics at the tumor-host interface. In vivo experiments confirm the presence of peritumoral acid gradients as well as cellular toxicity and extracellular matrix degradation in the normal tissue exposed to the acidic microenvironment. The acid-mediated tumor invasion model provides a simple mechanism linking altered glucose metabolism with the ability of tumor cells to form invasive cancers.

Acidosis↗

Radial GRASE: implementation and applications.

RAD-GRASE is an MRI sequence that combines radial (RAD) k-space scanning with the gradient and spin-echo (GRASE) technique. RAD-GRASE has the advantages of all radial data acquisition methods in that it can reduce motion sensitivity and correct motion-induced data errors, which can be exploited to achieve high-resolution diffusion-weighted imaging (DWI). One can obtain different types of image contrast, including DWI, T(1), T(2), and T(2)*, in RAD-GRASE by controlling the magnetization preparation and sequence timing. Moreover, because there is oversampling of the low spatial frequencies inherent to radial sequences, partial data reconstruction can be used to achieve multiple forms of image contrast from a single acquired data set, and to generate parametric image maps of equilibrium magnetization, T(2), and T(2) (dagger). The RAD-GRASE technique can also be used to achieve fat-suppressed and/or separated fat and water images by choosing the appropriate timing parameters.

Abdomen↗

Isotropic diffusion weighting in radial fast spin-echo magnetic resonance imaging.

Radial fast spin-echo (radial-FSE) methods enable multishot diffusion-weighted MRI (DWMRI) to be carried out without significant artifacts due to motion and/or susceptibility and can be used to generate DWMRI images with high spatial resolution. In this work, a novel method that allows isotropic diffusion weighting to be obtained in a single radial k-space data set is presented. This is accomplished by altering the direction of diffusion weighting gradients between groups of TR periods, which yield sets of radial lines that possess diffusion weighting sensitive to motion in different directions. By altering the diffusion weighting directions and controlling the view ordering appropriately within the sequence, an effectively isotropic diffusion-weighted image can be obtained within one radial-FSE scan. The order in which radial lines are acquired can also be controlled to yield data sets without significant artifacts due to motion, T(2) decay, and/or diffusion anisotropy.

Anisotropy↗

Processing of radial fast spin-echo data for obtaining T2 estimates from a single k-space data set.

Radially acquired fast spin-echo data can be processed to obtain T2-weighted images and a T2 map from a single k-space data set. The general approach is to use data at a specific TE (or narrow TE range) in the center of k-space and data at other TE values in the outer part of k-space. With this method high-resolution T2-weighted images and T2 maps are obtained in a time efficient manner. The mixing of TE data, however, introduces errors in the T2-weighted images and T2 maps that affect the accuracy of the T2 estimates. In this work, various k-space data processing methods for reconstructing T2-weighted images and T2 maps from a single radial fast spin-echo k-space data set are analyzed in terms of the accuracy of T2 estimates. The analysis is focused on the effect of image artifacts, object dependency, and noise on the T2 estimates. Results are presented in computer-generated phantoms and in vivo.

Algorithms↗

Interleaved acquisition of lipid and water images of the heart using a double-inversion fast spin-echo method.

In this work we present a new method for the improved detection of lipid infiltration in the heart. The method employs a double-inversion fast spin-echo technique where the acquisition of water- and lipid-suppressed k-space data is alternated between TR periods to produce co-registered lipid and water images from data acquired in a breath hold. The lipid and water images can then be combined to generate a lipid/water image with reduced artifacts due to flow and excellent contrast between lipid and myocardium. The method is demonstrated in ex vivo tissue and in vivo. This novel method may improve the detection of lipid infiltration in the heart in pathologies such as arrhythmogenic right ventricular dysplasia.

Algorithms↗

Design and demonstration of a miniature catheter for a confocal microendoscope.

The fluorescence confocal microendoscope provides high-resolution, in vivo imaging of cellular pathology during optical biopsy. The confocal microendoscope employs a flexible fiber-optic catheter coupled to a custom-built slit-scan confocal microscope. The catheter consists of a fiber-optic imaging bundle linked to a miniature objective and focus assembly. The 3-mm-diameter catheter may be used on its own or routed though the instrument channel of a commercial endoscope, adding microscopic imaging capability to conventional endoscopy. The design and performance of the miniature objective and focus assembly are discussed. Primary applications of the system include diagnosis of disease in the gastrointestinal tract and female reproductive system.

Catheterization↗

View-ordering in radial fast spin-echo imaging.

Radial MRI sequences are frequently used to obtain images with reduced sensitivity to motion. To decrease imaging time, multiple spin-echo acquisitions can be incorporated into radial sequences. In this case, different radial lines of Fourier data have different TE times and the resulting images can contain streaking artifacts due to T(2) decay. The streaking is not only dependent on the T(2) of the object and the timing of the data acquisition, but also on the order in which radial lines are collected (view order). The view ordering can easily be controlled to minimize artifacts due to T(2) decay as well as motion. Four view-ordering techniques are presented and evaluated for the radial FSE sequence.

Abdomen↗

Imaging of the ovary.

Epithelial ovarian cancer has the highest mortality rate among the gynecologic cancers and spreads beyond the ovary in 90% of the women diagnosed with ovarian cancer. Detection before the disease has spread beyond the ovary would significantly improve the survival from ovarian cancer, which is currently only 30% over 5 years, despite extensive efforts to improve the survival. This study describes initial investigation of the use of optical technologies to improve the outcome for this disease by detecting cancers at an earlier and more treatable stage. Women undergoing oophorectomy were recruited for this study. Ovaries were harvested for fluorescence spectroscopy, confocal microscopy, and optical coherence tomography. Fluorescence spectroscopy showed large diagnostic differences between normal and abnormal tissue at 270 and 340 nm excitation. Optical coherence tomography was able to image up to 2mm deep into the ovary with particular patterns of backscattered intensity observed in normal versus abnormal tissue. Fluorescence confocal microscopy was able to visualize sub-cellular structures of the surface epithelium and underlying cell layers. Optical imaging and/or spectroscopy has the potential to improve the diagnostic capability in the ovary, but extended systematic investigations are needed to identify the unique signatures of disease. The combination of optical technologies supported by modern molecular biology may lead to an instrument that can accurately detect early carcinogenesis.

Adolescent↗

Radial fast spin-echo method for T2-weighted imaging and T2 mapping of the liver.

PURPOSE: To evaluate a multishot radial fast-spin echo (RAD-FSE) method developed to improve the quality of abdominal T2-weighted imaging as well as the characterization of focal liver lesions. MATERIALS AND METHODS: The RAD-FSE sequence used in this work consisted of a preparatory period followed by a short echo train (ETL = 16). A novel radial k-space trajectory was used to minimize streaking artifacts due to T2 variations and motion. Small diffusion gradients (b = 1.2 mm/s(2)) were used to improve flow suppression. The quality of images obtained with RAD-FSE was compared to multishot 2DFT fast spin-echo (2DFT-FSE) and half-Fourier acquisition single-shot turbo-spin-echo (HASTE) images using data from 16 patients. A postprocessing algorithm was used to generate multiple high-resolution images (at different effective TE values) as well as a T2 map from a single RAD-FSE data set. The T2 maps were used to differentiate malignant from benign lesions for a set of 33 lesions ranging from 0.8-194 cm(3). RESULTS: RAD-FSE produces high-resolution images of the liver in a breath-hold without the motion artifacts of 2DFT-FSE methods, and without the blurriness and loss of small lesion detectability of HASTE. The inclusion of diffusion weighting in RAD-FSE decreases the signal from blood in hepatic vessels, which improves lesion visualization. The T2 values obtained by postprocessing a single RAD-FSE data set can differentiate malignant from benign lesions. The mean T2 values obtained for malignancies, hemangiomas, and cysts are 108 +/- 30 msec, 240 +/- 14 msec, and 572 +/- 334 msec, respectively. CONCLUSION: These results indicate that RAD-FSE produces abdominal images of higher quality than 2DFT-FSE and HASTE. In addition, lesions can be characterized using T2 maps generated from a single RAD-FSE data set.

Adolescent↗