Arthur L Boyer

Publications and source records attributed to Arthur L Boyer.

8 recordsLinked to original sources

Statistical process control for radiotherapy quality assurance.

Every quality assurance process uncovers random and systematic errors. These errors typically consist of many small random errors and a very few number of large errors that dominate the result. Quality assurance practices in radiotherapy do not adequately differentiate between these two sources of error. The ability to separate these types of errors would allow the dominant source(s) of error to be efficiently detected and addressed. In this work, statistical process control is applied to quality assurance in radiotherapy for the purpose of setting action thresholds that differentiate between random and systematic errors. The theoretical development and implementation of process behavior charts are described. We report on a pilot project is which these techniques are applied to daily output and flatness/symmetry quality assurance for a 10 MV photon beam in our department. This clinical case was followed over 52 days. As part of our investigation, we found that action thresholds set using process behavior charts were able to identify systematic changes in our daily quality assurance process. This is in contrast to action thresholds set using the standard deviation, which did not identify the same systematic changes in the process. The process behavior thresholds calculated from a subset of the data detected a 2% change in the process whereas with a standard deviation calculation, no change was detected. Medical physicists must make decisions on quality assurance data as it is acquired. Process behavior charts help decide when to take action and when to acquire more data before making a change in the process.

Humans↗

Optical detection of tumors in vivo by visible light tissue oximetry.

Endoscopy is a standard procedure for identifying tumors in patients suspected of having gastrointestinal (G.I.) cancer. The early detection of G.I. neoplasms during endoscopy is currently made by a subjective visual inspection that relies to a high degree on the experience of the examiner. This process can be difficult and unreliable, as tumor lesions may be visually indistinguishable from benign inflammatory conditions and the surrounding mucosa. In this study, we evaluated the ability of local ischemia detection using visible light spectroscopy (VLS) to differentiate neoplastic from normal tissue based on capillary tissue oxygenation during endoscopy. Real-time data were collected (i) from human subjects (N = 34) monitored at various sites during endoscopy (enteric mucosa, malignant, and abnormal tissue such as polyps) and (ii) murine animal subjects with human tumor xenografts. Tissue oximetry in human subjects during endoscopy revealed a tissue oxygenation (StO2%, mean +/- SD) of 46 +/- 22% in tumors, which was significantly lower than for normal mucosal oxygenation (72 +/- 4%; P < or = 0.0001). No difference in tissue oxygenation was observed between normal and non-tumor abnormal tissues (P = N.S.). Similarly, VLS tissue oximetry for murine tumors revealed a mean local tumor oxygenation of 45% in LNCaP, 50% in M21, and 24% in SCCVII tumors, all significantly lower than normal muscle tissue (74%, P < 0.001). These results were further substantiated by positive controls, where a rapid real-time drop in tumor oxygenation was measured during local ischemia induced by clamping or epinephrine. We conclude that VLS tissue oximetry can distinguish neoplastic tissue from normal tissue with a high specificity (though a low sensitivity), potentially aiding the endoscopic detection of gastrointestinal tumors.

Adult↗

Dosimetry and radiobiologic model comparison of IMRT and 3D conformal radiotherapy in treatment of carcinoma of the prostate.

INTRODUCTION: Intensity-modulated radiotherapy (IMRT) has introduced novel dosimetry that often features increased dose heterogeneity to target and normal structures. This raises questions of the biologic effects of IMRT compared to conventional treatment. We compared dosimetry and radiobiologic model predictions of tumor control probability (TCP) and normal tissue complication probability (NTCP) for prostate cancer patients planned for IMRT as opposed to standardized three-dimensional conformal radiotherapy (3DCRT). METHODS AND MATERIALS: Segmented multileaf collimator IMRT treatment plans for 32 prostate cancer patients were compared to 3DCRT plans for the same patients. Twenty-two received local-field irradiation (LFI), and 10 received extended-field irradiation (EFI) that included pelvic lymph nodes. For LFI, IMRT was planned for delivery of 2 Gy minimum dose to the prostate (> or =99% volume coverage) for 35 fractions. The 3DCRT plans, characterized by more homogenous dose to the target, were designed according to a different protocol to deliver 2 Gy to the center of the prostate for 37 fractions. Mean total dose from 35 fractions of IMRT was equal to mean total dose from 37 fractions of 3DCRT. For EFI, both IMRT and 3DCRT were planned for 2 Gy per fraction to a total dose of 50 Gy to prostate and pelvic lymph nodes, followed by 2 Gy per fraction to 20 Gy to the prostate alone. Treatment dose for EFI-IMRT was defined as minimum dose to the target, whereas for EFI-3DCRT, it was defined as dose to the center of the prostate. TCP was calculated for the prostate in the linear-quadratic model for two choices of alpha/beta. NTCP was calculated with the Lyman model for organs at risk, using Kutcher-Burman dose-volume histogram reduction with Emami parameters. RESULTS AND CONCLUSIONS: Dose to the prostate, expressed as mean +/- standard deviation, was 74.7 +/- 1.1 Gy for IMRT vs. 74.6 +/- 0.3 Gy for 3D for the LFI plans, and 74.8 +/- 0.6 Gy for IMRT vs. 71.5 +/- 0.6 Gy for 3D for the EFI plans. For the studied protocols, TCP was greater for IMRT than for 3D across the full range of target sensitivity, for both localized- and extended-field irradiation. For LFI, this was due to the smaller number of fractions (35 vs. 37) used for IMRT, and for EFI, this was due to the greater mean dose for IMRT, compared to 3D. For all organs, mean NTCP tended to be lower for IMRT than for 3D, although NTCP values were very small for both 3D and IMRT. Differences were statistically significant for rectum (LFI and EFI), bladder (EFI), and bowel (EFI). For both LFI and EFI, the calculated NTCPs qualitatively agreed with early published clinical data comparing genitourinary and gastrointestinal complications of IMRT and 3D. Present calculations support the hypothesis that accurately delivered IMRT for prostate cancer can limit dose to normal tissue by reducing treatment margins relative to conventional 3D planning, to allow a reduction in complication rate spanning several sensitive structures while maintaining or increasing tumor control probability.

Algorithms↗

Enhanced effectiveness of radiochemotherapy with tirapazamine by local application of electric pulses to tumors.

Tumor hypoxia is associated with resistance to radiotherapy and anticancer chemotherapy. However, it can be exploited to therapeutic advantage by concomitantly using hypoxic cytotoxins, such as tirapazamine (TPZ). Tumor electroporation offers the means to further increase tumor hypoxia by temporarily reducing tumor blood flow and therefore increase the cytotoxicity of TPZ. The primary objective of this work was to determine whether electric pulses combined with TPZ and radiotherapy (electroradiochemotherapy) was more efficacious than radiochemotherapy (TPZ + radiation). In these studies using the SCCVII tumor model in C3H mice, electroradiochemotherapy produced up to sixfold more tumor growth delay (TGD) than TPZ + radiation. In these studies, (1) large tumors (280 +/- 15 mm3) responded better to electroradiochemotherapy than small tumors (110 +/- 10 mm3), (2) TGD correlated linearly with tumor volume at the time of electroradiochemotherapy, (3) electric pulses induced a rapid but reversible reduction in O2 saturation, and (4) the electric field was highest near the periphery of the tumor in a 3D computer model. The findings suggested that electroradiochemotherapy gained its therapeutic advantage over TPZ + radiation by enhancing the cytotoxic action of TPZ through reduced tumor oxygenation. The greater antitumor effect achieved in large tumors may be related to tumor morphology and the electric-field distribution. These results suggest that electro-pulsation of large solid tumors may be of benefit to patients treated with radiation in combination with agents that kill hypoxic cells.

Animals↗

Quality assurance of magnetic resonance spectroscopic imaging-derived metabolic data.

PURPOSE: Spatially resolved metabolite maps, as measured by magnetic resonance spectroscopic imaging (MRSI) methods, are being increasingly used to acquire metabolic information to guide therapy, with metabolite ratio maps perhaps providing the most diagnostic information. We present a quality assurance procedure for MRSI-derived metabolic data acquired ultimately for guiding conformal radiotherapy. METHODS AND MATERIALS: An MRSI phantom filled with brain-mimicking solutions was custom-built with an insert holding eight vials containing calibration solutions of precisely varying metabolite concentrations that emulated increasing grade/density of brain tumor. Phantom metabolite ratios calculated from fully relaxed 1D, 2D, and 3D MRS data for each vial were compared with calibrated metabolite ratios acquired at 9.4 T. Additionally, 3D ratio maps were "discretized" to eight pseudoabnormality levels on a slice-by-slice basis and the accuracy of this procedure was verified. RESULTS: Regression analysis revealed expected linear relationships between experimental and calibration metabolite ratios with intercepts close to zero for the three acquisition modes. 1D MRS data agreed most with theoretical considerations (regression coefficient, b = 0.969; intercept 0.008). The 2D (b = 1.049; intercept -0.199) and 3D (correlation coefficient r(2) = 0.9978-0.7336 for five slices) MRSI indicated reduced MRS data quality in regions of degraded B(0) and B(1) homogeneity. Pseudoabnormality levels were found to be consistent with expectations within regions of adequate B(0) homogeneity. CONCLUSIONS: This simple phantom-based approach to generate baseline calibration curves for all MRS acquisition modes may be useful to identify temporal deviations from acceptable data quality in a routine clinical environment or for testing new MRS and MRSI acquisition software.

Aspartic Acid↗

Inverse planning for functional image-guided intensity-modulated radiation therapy.

Radiation therapy is an image-guided process whose success critically depends on the imaging modality used for treatment planning and the level of integration of the available imaging information. In this work, we establish a dose optimization framework for incorporating metabolic information from functional imaging modalities into the intensity-modulated radiation therapy (IMRT) inverse planning process and to demonstrate the technical feasibility of planning deliberately non-uniform dose distributions in accordance with functional imaging data. For this purpose, a metabolic map from functional images is discretized into a number of abnormality levels (ALs) and then fused with CT images. To escalate dose to the metabolically abnormal regions, we assume, for a given spatial point, a linear relation between the AL and the prescribed dose. But the formalism developed here is independent of the assumption and any other relation between AL and prescription is applicable. For a given AL and prescription relation, it is only necessary to prescribe the dose to the lowest AL in the target and the desired doses to other regions with higher AL values are scaled accordingly. To accomplish differential sparing of a sensitive structure when its functional importance (FI) distribution is known, we individualize the tolerance doses of the voxels within the structure according to their Fl levels. An iterative inverse planning algorithm in voxel domain is used to optimize the system with in homogeneous dose prescription. To model intra-structural trade-off, a mechanism is introduced through the use of voxel-dependent weighting factors, in addition to the conventional structure specific weighting factors which model the inter-structural trade-off. The system is used to plan a phantom case with a few hypothetical functional distributions and a brain tumour treatment with incorporation of magnetic resonance spectroscopic imaging data. The results indicated that it is technically feasible to produce deliberately non-uniform dose distributions according to the functional imaging requirements. Integration of functional imaging information into radiation therapy dose optimization allows for consideration of patient-specific biologic information and provides a significant opportunity to truly individualize radiation treatment. This should enhance our capability to safely and intelligently escalate dose and lays the technical foundation for future clinical studies of the efficacy of functional imaging-guided IMRT.

Algorithms↗

An investigation of a video-based patient repositioning technique.

PURPOSE: We have investigated a video-based patient repositioning technique designed to use skin features for radiotherapy repositioning. We investigated the feasibility of the clinical application of this system by quantitative evaluation of performance characteristics of the methodology. METHODS AND MATERIALS: Multiple regions of interest (ROI) were specified in the field of view of video cameras. We used a normalized correlation pattern-matching algorithm to compute the translations of each ROI pattern in a target image. These translations were compared against trial translations using a quadratic cost function for an optimization process in which the patient rotation and translational parameters were calculated. RESULTS: A hierarchical search technique achieved high-speed (compute correlation for 128 x 128 ROI in 512 x 512 target image within 0.005 s) and subpixel spatial accuracy (as high as 0.2 pixel). By treating the observed translations as movements of points on the surfaces of a hypothetical cube, we were able to estimate accurately the actual translations and rotations of the test phantoms used in our experiments to less than 1 mm and 0.2 degrees with a standard deviation of 0.3 mm and 0.5 degrees respectively. For human volunteer cases, we estimated the translations and rotations to have an accuracy of 2 mm and 1.2 degrees. CONCLUSION: A personal computer-based video system is suitable for routine patient setup of fractionated conformal radiotherapy. It is expected to achieve high-precision repositioning of the skin surface with high efficiency.

Algorithms↗

A three-source model for the calculation of head scatter factors.

Accurate determination of the head scatter factor Sc is an important issue, especially for intensity modulated radiation therapy, where the segmented fields are often very irregular and much less than the collimator jaw settings. In this work, we report an Sc calculation algorithm for symmetric, asymmetric, and irregular open fields shaped by the tertiary collimator (a multileaf collimator or blocks) at different source-to-chamber distance. The algorithm was based on a three-source model, in which the photon radiation to the point of calculation was treated as if it originated from three effective sources: one source for the primary photons from the target and two extra-focal photon sources for the scattered photons from the primary collimator and the flattening filter, respectively. The field mapping method proposed by Kim et al. [Phys. Med. Biol. 43, 1593-1604 (1998)] was extended to two extra-focal source planes and the scatter contributions were integrated over the projected areas (determined by the detector's eye view) in the three source planes considering the source intensity distributions. The algorithm was implemented using Microsoft Visual C/C++ in the MS Windows environment. The only input data required were head scatter factors for symmetric square fields, which are normally acquired during machine commissioning. A large number of different fields were used to evaluate the algorithm and the results were compared with measurements. We found that most of the calculated Sc's agreed with the measured values to within 0.4%. The algorithm can also be easily applied to deal with irregular fields shaped by a multileaf collimator that replaces the upper or lower collimator jaws.

Algorithms↗