PubMed Health⌕ Search

Biomedical subjects

Arun K Bhunia

Publications and source records attributed to Arun K Bhunia.

At least 19 recordsLinked to original sources

Hybridoma Ped-2E9 cells cultured under modified conditions can sensitively detect Listeria monocytogenes and Bacillus cereus.

Lymphocyte origin hybridoma Ped-2E9 cell-based cytotoxicity assay can detect virulent Listeria or Bacillus species, and its application in a cell-based biosensor for onsite use would be very attractive. However, maintaining enough viable cells on a sensor platform for a prolonged duration is a challenging task. In this study, key factors affecting the survival and growth of Ped-2E9 cells under modified conditions were investigated. When the Ped-2E9 cells were grown in media containing 5% fetal bovine serum in sealed tubes without any replenishment of nutrients or exogenous CO(2) supply, a large portion of the cells remained viable for 6 to 7 days and cells entered into G0/G1 resting phase. The media pH change was negligible and no cell death was observed in the first 4 days, then cells sequentially underwent apoptotic (fourth day onward) phase until day 7 after which a majority was dead. Subsequent cytotoxicity testing of 3- to 7-day stored Ped-2E9 cells sensitively detected virulent Listeria and Bacillus species. These data strongly suggest that Ped-2E9 cells can be maintained in viable state for 6 days in a sealed tube mimicking the environment in a potential sensor device for onsite use without the need for expensive cell culture facilities.

Animals↗

Antibody microarray detection of Escherichia coli O157:H7: Quantification, assay limitations, and capture efficiency.

A sandwich fluorescent immunoassay in a microarray format was used to capture and detect E. coli O157:H7. Here, we explored quantitative aspects, limitations, and capture efficiency of the assay. When biotinylated capture antibodies were used, the signal generated was higher (over 5-fold higher with some cell concentrations) compared to biotinylated protein G-bound capture antibodies. By adjusting the concentration of reporter antibody, a linear fluorescent response was observed from approximately 3.0 x 10(6) to approximately 9.0 x 10(7) cells/mL, and this was in agreement with the number of captured bacteria as determined by fluorescence microscopy. Capture efficiency calculations revealed that, as the number of bacteria presented for capture decreased, capture efficiency increased to near 35%. Optimization experiments, with several combinations of capture and reporter antibodies, demonstrated that the amount of bacteria available for capture (10(6) versus 10(8) cells/mL) affected the optimal combination. The findings presented here indicate that antibody microarrays, when used in sandwich assay format, may be effectively used to capture and detect E. coli O157:H7.

Antibodies, Bacterial↗

Optical forward-scattering for detection of Listeria monocytogenes and other Listeria species.

We demonstrate here the development of a non-invasive optical forward-scattering system, called 'scatterometer' for rapid identification of bacterial colonies. The system is based on the concept that variations in refractive indices and size, relative to the arrangement of cells in bacterial colonies growing on a semi-solid agar surface will generate different forward-scattering patterns. A 1.2-1.5mm colony size for a 1mm laser beam and brain heart infusion agar as substrate were used as fixed variables. The current study is focused on exploring identification of Listeria monocytogenes and other Listeria species exploiting the known differences in their phenotypic characters. Using diffraction theory, we could model the scattering patterns and explain the appearance of radial spokes and the rings seen in the scattering images of L. monocytogenes. Further, we have also demonstrated development of a suitable software for the extraction of the features (scalar values) calculated from images of the scattering patterns using Zernike moment invariants and principal component analysis and were grouped using K-means clustering. We achieved 91-100% accuracy in detecting different species. It was also observed that substrate variations affect the scattering patterns of Listeria. Finally, a database was constructed based on the scattering patterns from 108 different strains belonging to six species of Listeria. The overall system proved to be simple, non-invasive and virtually reagent-less and has the potential for automated user-friendly application for detection and differentiation of L. monocytogenes and other Listeria species colonies grown on agar plates within 5-10 min analysis time.

Biosensing Techniques↗

Performance evaluation of a low conductive growth medium (LCGM) for growth of healthy and stressed Listeria monocytogenes and other common bacterial species.

The performance of a low conductive growth medium (LCGM) (conductivity of <1300 microS) was evaluated for its ability to support growth of food borne bacterial pathogens including Listeria monocytogenes and to determine the expression of the two key virulence proteins in L. monocytogenes for possible applications in an impedance-based microfluidic biochip detection platform. Growth of Listeria was monitored spectrophotometrically and the lag phase, generation time, growth rate and maximum population density were determined using the Gompertz equation. LCGM had a lag phase of 2.3 h and showed a higher cell density compared to Luria Bertini (LB) broth. Length of lag phase was highly dependent on initial inoculum concentrations. The changes in conductivity with respect to growth in the low conductive medium were monitored using a conductivity probe. L. monocytogenes growth could be detected within 2 h (0.1 mS) in LCGM and within 6 h in LB. The performance of the media was also evaluated for the recovery of Listeria cells exposed to various stresses as 42 degrees C for 1, 2 or 6 h, an osmotic stress in 10.5% NaCl, an acidic stress at pH 2, 3 or 5 and a combined stress of 10.5% NaCl, pH 5 and 1 h exposure at 42 degrees C. The recovery rate was comparable with that of Tryptic soy broth containing yeast extract (TSBYE). L. monocytogenes in LCGM supported the expression of two key virulence markers, actin polymerization protein (ActA) and internalin B (InlB), which could be detected using specific antibodies. In general LCGM also supported the growth of several other bacterial species suggesting its implication in microbial quality monitoring of products. In conclusion, LCGM is a sensitive low conductive medium that supports the growth as well as the expression of virulence markers for potential applications in sensitive detection of L. monocytogenes or other food borne pathogens in impedance-based sensor platform.

Colony Count, Microbial↗

A multifunctional micro-fluidic system for dielectrophoretic concentration coupled with immuno-capture of low numbers of Listeria monocytogenes.

In this study, we demonstrated a micro-fluidic system with multiple functions, including concentration of bacteria using dielectrophoresis (DEP) and selective capture using antibody recognition, resulting in a high capture efficiency of bacterial cells. The device consisted of an array of oxide covered interdigitated electrodes on a flat silicon substrate and a approximately 16 microm high and approximately 260 microm wide micro-channel within a PDMS cover. For selective capture of Listeria monocytogenes from the samples, the channel surface was functionalized with a biotinylated BSA-streptavidin-biotinylated monoclonal antibody sandwich structure. Positive DEP (at 20 V(pp) and 1 MHz) was used to concentrate bacterial cells from the fluid flow. DEP could collect approximately 90% of the cells in a continuous flow at a flow rate of 0.2 microl min(-1) into the micro-channel with concentration factors between 10(2)-10(3), in sample volumes of 5-20 microl. A high flow rate of 0.6 microl min(-1) reduced the DEP capture efficiency to approximately 65%. Positive DEP attracts cells to the edges of the electrodes where the field gradient is the highest. Cells concentrated by DEP were captured by the antibodies immobilized on the channel surface with efficiencies of 18 to 27% with bacterial cell numbers ranging from 10(1) to 10(3) cells. It was found that DEP operation in our experiments did not cause any irreversible damage to bacterial cells in terms of cell viability. In addition, increased antigen expression (antigens to C11E9 monoclonal antibody) on cell membranes was observed following the exposure to DEP.

Antibodies, Monoclonal↗

A microfluidic flow-through device for high throughput electrical lysis of bacterial cells based on continuous dc voltage.

Interest in electrical lysis of biological cells on a microfludic platform has increased because it allows for the rapid recovery of intracellular contents without introducing lytic agents. In this study we demonstrated a simple microfluidic flow-through device which lysed Escherichia coli cells under a continuous dc voltage. The E. coli cells had previously been modified to express green fluorescent protein (GFP). In our design, the cell lysis only happened in a defined section of a microfluidic channel due to the local field amplification by geometric modification. The geometric modification also effectively decreased the required voltage for lysis by several folds. We found that local field strength of 1000-1500 V/cm was required for nearly 100% cell death. This threshold field strength was considerably lower than the value reported in the literature, possibly due to the longer duration of the field [Lee, S.W., Tai, Y.C., 1999. Sens. Actuators A: Phys. 73, 74-79]. Cell lysis was detected by both plate count and fluorescence spectroscopy. The cell membrane was completely disintegrated in the lysis section of the microfluidic device, when the field strength was higher than 2000 V/cm. The devices were fabricated using low-cost soft lithography with channel widths considerably larger than the cell size to avoid clogging and ensure stable performance. Our tool will be ideal for high throughput processing of bacterial cells for chemical analysis of intracellular contents such as DNA and proteins. The application of continuous dc voltage greatly simplified the instrumentation compared to devices using electrical pulses for similar purposes. In principle, the same approach can also be applied for lysis of mammalian cells and electroporative transfection.

Cell Culture Techniques↗

Prevalence of antibodies reactive to pathogenic and nonpathogenic bacteria in preimmune serum of New Zealand white rabbits.

Polyclonal antibodies are typically produced in rabbits. The rabbit's health plays an important role in the quality of antibodies produced. Therefore, recommendations have been made by organizations on which bacteria and how frequently to test rabbit colonies. Since it is well known that rabbits may contain cross-reactive antibodies in their preimmune serum, it is common to test the rabbits for reactivity prior to immunization. Here preimmune sera from 19 different rabbits were tested with ELISA against 27 pathogenic and nonpathogenic bacterial cultures. ELISA results showed that Salmonella enterica serovar Typhimurium and Bacillus cereus AS4-12 had the highest average absorbance values (0.60 and 0.54, respectively) and the most preimmune serum samples testing positive was 17. Pseudomonas putrefaciens and B. subtilis had the lowest absorbance values (< 0.1) and did not test positive in any of the preimmune serum samples. Fourteen of the 27 cultures showed positive reactions with 50% or more of the preimmune serum samples tested. Fifty-three percent of the rabbit preimmune sera showed positive reactions with 10 or more bacterial cultures. In Western blot analyses, selected serum samples showing the highest ELISA values reacted with bands in the 97, 36, and 29 kDa regions or with bands in the 63 kDa and 32 kDa regions. Data suggest that the presence of cross-reactive antibodies in the preimmune serum is a common problem amongst the samples tested. Extensive preimmune serum testing should be implemented when polyclonal antibodies are intended for diagnostic testing.

Animals↗

Adhesion characteristics of Listeria adhesion protein (LAP)-expressing Escherichia coli to Caco-2 cells and of recombinant LAP to eukaryotic receptor Hsp60 as examined in a surface plasmon resonance sensor.

Listeria adhesion protein (LAP) is an important adhesion factor in Listeria monocytogenes and interacts with its cognate receptor, mammalian heat shock protein 60 (Hsp60). The genetic identity of LAP was determined to be alcohol acetaldehyde dehydrogenase (Aad). A recombinant Escherichia coli strain expressing aad confirmed the involvement of Aad in adhesion to Caco-2 cells. Binding kinetics (ka) of recombinant LAP (rLAP) to Hsp60 was examined in a surface plasmon resonance sensor and was determined to be 5.35 x 10(8) M(-1) s(-1) and it was equivalent to the binding of anti-Hsp60 antibody (ka = 2.15 x 10(9) M(-1) s(-1)) to Hsp60. In contrast, Internalin B, an adhesion/invasion protein from L. monocytogenes, used as a control, had binding kinetics (ka) of only 2.9 x 10(6) M(-1) s(-1). The KD value of rLAP was 1.68 x 10(-8) M, which was significantly lower than Internalin B (KD = 6.5 x 10(-4) M). These results suggest that Hsp60 has significantly higher avidity for anti-Hsp60 antibody and LAP than Internalin B. In summary, LAP is identified as an alcohol acetaldehyde dehydrogenase and binding of recombinant E. coli to Caco-2 cells or rLAP to Hsp60 protein was found to be highly specific.

Adhesins, Bacterial↗

Selective enrichment media affect the antibody-based detection of stress-exposed Listeria monocytogenes due to differential expression of antibody-reactive antigens identified by protein sequencing.

Selective enrichment broths are frequently used to recover stressed Listeria cells to detectable levels, but the ability of antibodies to detect these cells from various commonly used enrichment media is unknown. In this study, a polyclonal (PAb) and monoclonal (MAb) antibody were used to examine the variation in antigen expression on healthy or stress-recovered Listeria monocytogenes cells grown in brain heart infusion broth, buffered Listeria enrichment broth (BLEB), Listeria repair broth (LRB), University of Vermont medium (UVM), and Fraser broth (FB) for immunodetection. Indirect enzyme-linked immunosorbent assay (ELISA) data showed that L. monocytogenes subjected to stresses (acid, cold, heat, and salt) and then grown in BLEB gave the highest reaction with the anti-Listeria PAb while those grown in LRB gave the highest reaction with the MAb C11E9. Cells grown in UVM and FB gave poor ELISA values with both antibodies. Western blotting with PAb revealed differential expression of surface proteins of 62, 58, 50, 43, and 30 kDa on L. monocytogenes cells, with most proteins displaying elevated expression in BLEB and LRB but reduced or no expression in UVM or FB. Similar differential expressions were noticed for C11E9. PAb-reactive proteins were identified as putative LPXTG-motif cell-wall anchor-domain protein (62 kDa; lmo0610), flavocytochrome C fumarate reductase chain A homolog protein (58 kDa; lmo0355), enolase (50 kDa; lmo2455), glyceraldehyde 3-phosphate dehydrogenase (43 kDa; lmo2459), and hypothetical phospho-sugar binding protein (30 kDa; lmo0041), respectively, and the MAb-reactive 66-kDa protein was confirmed to be N-acetylmuramidase (lmo2691). In conclusion, BLEB and LRB favorably supported increased expression of antigens and proved to be superior to UVM and FB for immunodetection of stressed L. monocytogenes cells.

Antibodies, Monoclonal↗

Conductivity and pH dual detection of growth profile of healthy and stressed Listeria monocytogenes.

In this study, growth of Listeria monocytogenes in a low conductivity growth medium (LCGM) was simultaneously monitored by conductivity and pH measurements. Detection times obtained from the conductivity and pH growth curves were inversely related to the initial concentration of L. monocytogenes in the medium. Linear responses were found by plotting detection times obtained from both conductivity and pH growth curves as a function of initial cell concentration in the range of 10(2) to 10(7) cfu/mL. The detection time was approximately 12 and 2 h for 10(2) and 10(7) cfu/mL of viable L. monocytogenes, respectively, using the conductivity growth curves, whereas it was approximately 1 h less using the pH growth curves. This dual detection system was used for evaluating the growth of acid-, temperature-, and salt-treated L. monocytogenes in the medium. Acid stress at pH 2 and 3 for 3 h caused approximately 12 and 4 h delay in the detection time on pH growth curves, while stress at pH 5 for 3 h did not cause a significant delay in detection time. Delay in detection times was also observed for L. monocytogenes cells exposed to 45 degrees C for more than 1 h (2 and 6 h). Exposure to 10% NaCl for 3 h did not cause visible delay in the detection time. These observations on detection times for stressed L. monocytogenes had a consistent trend with the cell number decrease determined by surface plating method.

Colony Count, Microbial↗

Mechanistic study of membrane concentration and recovery of Listeria monocytogenes.

Detection of the foodborne pathogen Listeria monocytogenes requires that food samples be processed to remove proteins and lipids, concentrate microorganisms to a detectable concentration, and recover the concentrated cells in a small volume compatible with micron-scale biochips. Mechanistic considerations addressed in this research include the roles of membrane structure, pore size, and detergents in maximizing recovery of cells from a complex biological fluid. The fluid in this case was a food sample (hotdog extract) inoculated with L. monocytogenes. This study showed how membrane filtration using a syringe filter is able to concentrate L. monocytogenes by 95x with up to 95% recovery of living microorganisms by concentrating 50 mL of food sample into a volume of 500 microL. Tween 20 was added to the sample to prevent irreversible adsorption of the microorganism to the membrane and thereby help to ensure high recovery. Comparison of polycarbonate, mixed cellulose, nylon, and PVDF membranes with 0.2 to 0.45 microm pores showed the 0.2 microm polycarbonate membrane with straight through, mono-radial pores gives the highest recovery of living microorganisms. The mixed cellulose, nylon, and PVDF membranes have a fibrous structure whose characteristic openings are much larger than their effective pore size cut-offs of 0.22 or 0.45 microm. We define conditions for rapid membrane-based cell concentration and recovery that has the potential to supplant enrichment steps that require a day or more. This approach has the added benefit of facilitating examination of a large amount of fluid volume by reducing its volume to a range that is compatible with the microliter scales of biochip or other biosensor detection systems.

Filtration↗

Specific detection of cytopathogenic Listeria monocytogenes using a two-step method of immunoseparation and cytotoxicity analysis.

The development of rapid methods for detection of viable Listeria monocytogenes is crucial to prevent listeriosis and product recalls. While immunomagnetic separation has been used for isolating Listeria spp., lack of specificity and pathogenicity determination render this method unsatisfactory. A two-step method using Protein A agarose beads (Immunobeads) coated with a more specific antibody, monoclonal antibody (MAb)-C11E9 for L. monocytogenes was developed. Immunobeads were allowed to capture Listeria cells from a variety of samples and tested for cytopathogenic action on a murine hybridoma B-lymphocyte, Ped-2E9 cell line by Trypan blue staining, and by an alkaline phosphatase (AP)-based cytotoxicity assay. The two-step method was used to test uninoculated hotdogs, bologna, and raw beef, chicken, and pork samples, following selective enrichment in half-Fraser broth. Pure culture studies proved the assay to be specific for L. monocytogenes, while a similar assay with Dynal Anti-Listeria immunomagnetic beads was positive for L. monocytogenes, L. ivanovii, and L. seeligeri. Detection and confirmation of cytopathogenicity of Listeria cells from food samples after 24-h selective enrichment were completed in 2-4 h. Isolates were further analyzed by the CAMP test for hemolytic activity and RiboPrinter for genomic patterns. Using immunoseparation and cytotoxicity as a two-step rapid method, viable L. monocytogenes could be isolated, detected, and confirmed as cytopathogenic in 28 h or less.

Animals↗

Cytotoxicity potential and genotypic characterization of Escherichia coli isolates from environmental and food sources.

The presence of Escherichia coli isolates in the environment is a potential source of contamination of food and water supplies. Moreover, these isolates may harbor virulence genes that can be a source of new forms of pathogenic strains. Here, using multiplex PCR, we examined the presence of virulence gene markers (stx1, stx2, eaeA, hlyA) in 1,698 environmental isolates of E. coli and 81 isolates from food and clinical sources. The PCR analysis showed that approximately 5% (79 of 1,698) of the total environmental isolates and 96% (79 of 81) of the food and clinical isolates were positive for at least one of the genes. Of the food and clinical isolates, 84% (68 of 81 isolates) were positive for all four genes. Of the subset of environmental isolates chosen for further analysis, 16% (13 of 79 isolates) were positive for stx2 and 84% (66 of 79 isolates) were positive for eaeA; 16 of the latter strains were also positive for hlyA. The pathogenic potentials of 174 isolates (81 isolates from food and clinical sources and 93 isolates from environmental sources) were tested by using a cytotoxicity assay based on lactate dehydrogenase release from Vero cells. In general, 97% (79 of 81) of the food and clinical isolates and 41% (39 of 93) of the environmental isolates exhibited positive cytotoxicity. High cytotoxicity values correlated to the presence of stx genes. The majority of hly-positive but stx-negative environmental isolates also exhibited a certain degree of cytotoxicity. Isolates were also tested for sorbitol utilization and were genotyped by ribotyping and by repetitive extragenic palindromic PCR (REP-PCR) as potential means of quickly identifying virulent strains from the environment, but none of these methods could be used to distinguish cytotoxic environmental isolates. Only 31% of the isolates were negative for sorbitol fermentation, and none of the isolates had common ribotypes or REP-PCR fingerprints. This study suggests that overall higher cytotoxicity values correlated with the production of stx genes, and the majority of hly-positive but stx-negative environmental isolates also exhibited a certain degree of cytotoxicity. This study demonstrated that there is widespread distribution of potentially virulent E. coli strains in the environment that may be a cause of concern for human health.

Animals↗

Rapid Ped-2E9 cell-based cytotoxicity analysis and genotyping of Bacillus species.

Bacillus species causing food-borne disease produce multiple toxins eliciting gastroenteritis. Toxin assays with mammalian cell cultures are reliable but may take 24 to 72 h to complete and also lack sensitivity. Here, a sensitive and rapid assay was developed using a murine hybridoma Ped-2E9 cell model. Bacillus culture supernatants containing toxins were added to a Ped-2E9 cell line and analyzed for cytotoxicity with an alkaline phosphatase release assay. Most Bacillus cereus strains produced positive cytotoxicity results within 1 h, and data were comparable to those obtained with the standard Chinese hamster ovary (CHO)-based cytotoxicity assay, which took about 72 h to complete. Moreover, the Ped-2E9 cell assay had 25- to 58-fold-higher sensitivity than the CHO assay. Enterotoxin-producing Bacillus thuringiensis also gave positive results with Ped-2E9 cells, while several other Bacillus species were negative. Eight isolates from food suspected of Bacillus contamination were also tested, and only one strain, which was later confirmed as B. cereus, gave a positive result. In comparison with two commercial diarrheal toxin assay kits (BDE-VIA and BCET-RPLA), the Ped-2E9 assay performed more reliably. Toxin fractions of >30 kDa showed the highest degree of cytotoxicity effects, and heat treatment significantly reduced the toxin activity, indicating the involvement of a heat-labile high-molecular-weight component in Ped-2E9 cytotoxicity. PCR results, in most cases, were in agreement with the cytotoxic potential of each strain. Ribotyping was used to identify cultures and indicated differences for several previously reported isolates. This Ped-2E9 cell assay could be used as a rapid (approximately 1-h) alternative to current methods for sensitive detection of enterotoxins from Bacillus species.

Animals↗

Detection of low levels of Listeria monocytogenes cells by using a fiber-optic immunosensor.

Biosensor technology has a great potential to meet the need for sensitive and nearly real-time microbial detection from foods. An antibody-based fiber-optic biosensor to detect low levels of Listeria monocytogenes cells following an enrichment step was developed. The principle of the sensor is a sandwich immunoassay where a rabbit polyclonal antibody was first immobilized on polystyrene fiber waveguides through a biotin-streptavidin reaction to capture Listeria cells on the fiber. Capture of cells on the fibers was confirmed by scanning electron microscopy. A cyanine 5-labeled murine monoclonal antibody, C11E9, was used to generate a specific fluorescent signal, which was acquired by launching a 635-nm laser light from an Analyte 2000 and collected by a photodetector at 670 to 710 nm. This immunosensor was specific for L. monocytogenes and showed a significantly higher signal strength than for other Listeria species or other microorganisms, including Escherichia coli, Enterococcus faecalis, Salmonella enterica, Lactobacillus plantarum, Carnobacterium gallinarum, Hafnia alvei, Corynebacterium glutamicum, Enterobacter aerogenes, Pseudomonas aeruginosa, and Serratia marcescens, in pure or in mixed-culture setup. Fiber-optic results could be obtained within 2.5 h of sampling. The sensitivity threshold was about 4.3 x 10(3) CFU/ml for a pure culture of L. monocytogenes grown at 37 degrees C. When L. monocytogenes was mixed with lactic acid bacteria or grown at 10 degrees C with 3.5% NaCl, the detection threshold was 4.1 x 10(4) or 2.8 x 10(7) CFU/ml, respectively. In less than 24 h, this method could detect L. monocytogenes in hot dog or bologna naturally contaminated or artificially inoculated with 10 to 1,000 CFU/g after enrichment in buffered Listeria enrichment broth.

Animals↗

Heat shock protein 60 acts as a receptor for the Listeria adhesion protein in Caco-2 cells.

The 104-kDa Listeria adhesion protein (LAP) in Listeria monocytogenes is involved in binding to various mammalian cell lines. However, the receptor that interacts with LAP in eukaryotic cells is unknown. In this study, scanning immunoelectron microscopy qualitatively demonstrated greater binding capacity of wild-type (WT) L. monocytogenes strain (F4244) than a LAP-deficient mutant strain (KB208) to Caco-2 cells. The goal of this study was identification of the host cell receptor for LAP. Using a Western blot ligand overlay assay, we identified a protein of 58 kDa to be the putative receptor for LAP from Caco-2 cells. N-terminal sequencing and subsequent database search identified this protein as heat shock protein 60 (Hsp60). Modified immunoseparation with protein A-Sepharose beads bound to the LAP-specific monoclonal antibody H7 (MAb-H7) and a sequential incubation with LAP preparation and Caco-2 lysate confirmed the receptor to be the same 58-kDa protein. Western blot analysis with anti-Hsp60 MAb of whole-cell adhesion between Caco-2 and WT also revealed the receptor protein to be a 58-kDa protein, thus corroborating the identification of Hsp60 as a host cell receptor for LAP. Furthermore, the anti-Hsp60 antibody also caused approximately 74% reduction in binding of L. monocytogenes WT to Caco-2 cells, whereas a control antibody, C11E9, had no effect on binding. The adhesion mechanism of L. monocytogenes to eukaryotic cells is a complex process, and identification of Hsp60 as a receptor for LAP adds to the list of previously discovered ligand-receptor modules that are essential to achieve successful adhesion.

Adhesins, Bacterial↗

Characterization and application of a Listeria monocytogenes reactive monoclonal antibody C11E9 in a resonant mirror biosensor.

Typical detection of Listeria monocytogenes involves selective enrichment, isolation and biochemical testing. Development of antibodies to Listeria species has improved detection; however, most antibodies detect all species of Listeria. A previously developed monoclonal antibody (MAb)-C11E9 was examined for its reaction to 13 L. innocua and 40 L. monocytogenes strains representing all 13 serotypes by ELISA. Absorbance values for L. monocytogenes strains were 0.44-3.58 and for L. innocua 0.22-1.44. ELISA reactions were divided into three arbitrary groups of high (Abs 1.0 or higher), intermediate (0.6-0.99) and low (0.18-0.59). Most L. monocytogenes strains (32/41, 78%) were in the high group while only 23% (3/13) of L. innocua were in the same group. In the Western blot assay, antibody reacted with phosphate-buffered saline (PBS) extracted protein preparations of 52, 66 and 97 kDa. Ribopattern of all strains was analyzed and no clear relationship was observed for antibody reaction and ribotype of a given strain. MAb C11E9 was used in a resonant mirror biosensor (IAsys sensor), but failed to detect any viable intact L. monocytogenes cells at levels as high as 10(8) cells/ml; however, it showed binding (85-150 arc/s) with the surface protein preparations containing the 97-, 66- and 52-kDa proteins at 208 mug/ml. Binding kinetics of L. monocytogenes and L. innocua surface protein extracts showed significantly (p<0.05) higher responses than the three other Listeria species (L. ivanovii, L. welshimeri and L. grayi), which could be detected in 10-20 min. These data corroborate with ELISA results. In summary, this study suggest that MAb-C11E9 is suitable for detection of all serotypes of L. monocytogenes despite cross-reaction with L. innocua and could be used for detection of soluble protein extracts in the resonant mirror (IAsys) biosensor.

Antibodies, Monoclonal↗

Micro-assembly of functionalized particulate monolayer on C18-derivatized SiO2 surfaces.

This work describes a simple approach to immobilize functionalized colloidal microstructures onto a C(18)-coated SiO(2) substrate via specific or non-specific bio-mediated interactions. Biotinylated bovine serum albumin pre-adsorbed onto a C(18) surface was used to mediate the surface assembly of streptavidin-coated microbeads (2.8 microm), while a bare C(18) surface was used to immobilize anti-Listeria antibody-coated microbeads (2.8 microm) through hydrophobic interactions. For a C(18) surface pre-adsorbed with bovine serum albumin, hydrophobic polystyrene microbeads (0.8 microm) and positively charged dimethylamino microbeads (0.8 microm) were allowed to self-assemble onto the surface. A monolayer with high surface coverage was observed for both polystyrene and dimethylamino microbeads. The adsorption characteristics of Escherichia coli and Listeria monocytogenes on these microbead-based surfaces were studied using fluorescence microscopy. Both streptavidin microbeads pre-adsorbed with biotinylated anti-Listeria antibody and anti-Listeria antibody-coated microbeads showed specific capture of L. monocytogenes, while polystyrene and dimethylamino microbeads captured both E. coli and L. monocytogenes non-specifically. The preparation of microbead-based surfaces for the construction of microfluidic devices for separation, detection, or analysis of specific biological species is discussed.

Adsorption↗