PubMed Health⌕ Search

Biomedical subjects

Asa Emmer

Publications and source records attributed to Asa Emmer.

7 recordsLinked to original sources

A screening procedure for the solubilization of chloroplast membrane proteins from the marine green macroalga Ulva lactuca using RP-HPLC-MALDI-MS.

A protocol for purification and analysis of chloroplast membrane proteins in the green macroalga Ulva lactuca has been developed, including reversed phase high performance liquid chromatography (RP-HPLC) and matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). Five different solvents were evaluated for extraction of membrane proteins by three methods. The highest protein yield was achieved when proteins were extracted directly from the chloroplasts using the solvent hexafluoroisopropanol. A range of proteins of increasing hydrophobicity was separated by HPLC. Analysis of both HPLC fractions and non-separated samples by MALDI-TOF-MS revealed proteins with molecular weights spanning between 1 and 376 kDa.

Algal Proteins↗

Capillary electrophoretic separation and fractionation of hydrophobic peptides onto a pre-structured matrix assisted laser desorption/ ionization target for mass spectrometric analysis.

A CE separation of hydrophobic peptides followed by fractionation onto a prestructured MALDI target and off-line MS analysis was performed. An improved and partially automated manufacturing procedure of the previously described MALDI target is presented. This target is structurally coated with silicone and especially developed for hydrophobic peptides and proteins. Here, the target plate was designed specifically for the CE fraction collection. Different solvents were evaluated to meet the requirements of peptide solubility and compatibility to both the CE and MALDI methods and to the fractionation procedure. CE-MALDI-MS analysis of nine highly hydrophobic peptides from cyanogen bromide-digested bacteriorhodopsin is demonstrated.

Amino Acid Sequence↗

Capillary electrophoretic and mass spectrometric analysis of a polydisperse fluorosurfactant.

A fluorosurfactant has been studied using capillary electrophoresis and mass spectrometry. The fluorosurfactant, FC134, can be used as a buffer additive in capillary electrophoresis in order to decrease wall adsorption of proteins and in micellar electrokinetic chromatography. However, it has been discovered that this fluorosurfactant is polydisperse, thus containing substances with different lengths and structures. In this work, the fluorosurfactant sample components were separated by capillary electrophoresis. An uncoated as well as a poly(vinyl alcohol)-coated capillary were used with running electrolytes containing methanol and acetic acid. Following the capillary electrophoretic separation, fractions were collected for further analysis by MALDI-MS. Non-fractionated samples were also analyzed both by MALDI-MS and by ESI-MS.

Journal Article↗

Membrane protein and peptide sample handling for MS analysis using a structured MALDI target.

Different sample handling methods for hydrophobic proteins and peptides were evaluated in association with the utilization of a structured matrix-assisted laser/desorption ionization (MALDI) target for increased sensitivity. The fluorinated organic solvent hexafluoroisopropanol (HFIP) was used for the solubilization of both the full-length protein bacteriorhodopsin (BR) and a cyanogen bromide digest thereof, and compared to the performance of the non-ionic detergents octyl-beta-D-glucopyranoside (OG), dodecyl-beta-D-maltoside (DM), and Triton X-100. A concentrating effect was seen when using the structured MALDI plate for BR dissolved in all the different detergents, of which OG generated the best-quality spectra for the full-length integral membrane protein as well as for the hydrophobic peptides. However, the uneven analyte distribution obtained with the detergent preparations required selective and thus time-consuming acquisition of spectra. When instead HFIP was used as sample solvent, a tenfold increase in sensitivity was achieved for full-length BR. Addition of acids to the HFIP-solubilized sample, or to the MALDI matrix solution, improved the signals for a few of the peptides, while degrading the spectra of others. Consequently, the addition of acid could be used as a complementary sample preparation method for hydrophobic peptides. On-target washing to remove contaminants (e.g., salt) was performed, and a recrystallization protocol for signal improvement specifically suited for hydrophobic peptides is described. Results from digestion and solubilization in different micro centrifuge tubes were examined to determine the influence of different materials on the possible sample loss due to wall adhesion. Studies of sample solution storage times suggest immediate analysis after solubilization to obtain best results.

Membrane Proteins↗

Simple fabrication of a structured matrix-assisted laser desorption/ionization target coating for increased sensitivity in mass spectrometric analysis of membrane proteins.

A new prestructured target plate for matrix-assisted laser desorption/ionization (MALDI) was developed specifically for hydrophobic integral membrane proteins. This sample support contains predefined concentrating sample spots with a focusing effect on droplets with a high content of hexafluoroisopropanol (HFIP). This fluorinated organic solvent is advantageous for solubilizing hydrophobic proteins that are not soluble in water or the organic solvents normally used in sample preparation protocols for MALDI-MS. The prestructured plate was constructed by coating a regular steel plate with a thin layer of a silicone polymer, leaving sample spots of bare steel. Fabrication of the concentrating silicone structure was fast and very straightforward, without expensive or complicated equipment. Removing the layer, and thus regenerating the steel plate, was done by a simple washing procedure. The application and cleaning procedure are not constrained by a particular design of sample support or to any specific brand of mass spectrometer. When using the prestructured MALDI plate with HFIP as the sample solvent for 17 pmol of a cyanogen bromide digest of the highly hydrophobic membrane protein bacteriorhodopsin, an improved focusing effect and an increase of more than five-fold in average sensitivity were observed, compared with a regular steel target. Experimental results show a two-fold increase in average sensitivity when the new prestructured target plate was used, compared with a commercially available concentrating support.

Amino Acid Sequence↗

Characterization of micromachined hollow tips for two-dimensional nanoelectrospray mass spectrometry.

In this work an improved design of chip-based nanoelectrospray nozzles is reported. Two-dimensional matrices of out-of-plane 10 microm i.d. silicon dioxide tips with a tapered shape were manufactured using deep reactive ion etching technology. Using a peptide sample, six micromachined tips and six commercially pulled silica capillary tips were compared employing an ion trap mass spectrometer. At a flow rate of 100 nL/min, the detectability obtained was approximately the same for the two types of tips. The relative standard deviation of the signal-to-noise ratio for the peptides between six different tips was on average 22% for the micromachined tips and 45% for the pulled capillary tips. The usefulness of the micromachined tips for analysis of non-covalent protein-ligand complexes was demonstrated by the analysis of a sample of RNase A and cytidine 2'-monophosphate. In another test, analyzing a tryptic digest of 1 pmol/microL cytochrome C, 18 peptides corresponding to a 82% sequence coverage were detected. Using MS/MS, the whole sequence of an 11 amino acid cytochrome C fragment was obtained. Computer simulations were performed on the shape and magnitude of the electrical field around micromachined and pulled capillary tips. To reach the threshold electric field density at the tip apex required to initiate an electrospray, a higher electrospray voltage was needed for the chip-based tips compared with pulled capillary tips. This is due to the influence of the chip base.

Animals↗

Characterization of proteinases from Antarctic krill (Euphausia superba).

Fractions of three trypsin-like proteinases, TL I, TL II, and TL III, a chymotrypsin-like proteinase, CL, two carboxypeptidase A enzymes, CPA I and CPA II and two carboxypeptidase B enzymes, CPB I and CPB II, from Antarctic krill (Euphausia superba) have been characterized with respect to purity by the means of capillary electrophoresis, CE, and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The masses of the trypsin-like and chymotrypsin-like proteinases were determined to be 25,020, 25,070, 25,060, and 26,260Da for TL I, TL II, TL III, and CL, respectively. The masses of the CPA enzymes are likely 23,170 and 23,260Da, whereas the CPB enzyme masses likely are 33,730 and 33,900Da. The degradation efficiency and cleavage pattern of the trypsin-like proteinases were studied with native myoglobin as a model substrate using CE, MALDI-TOF-MS, and nanoelectrospray mass spectrometry (nESI-MS). The degradation efficiency of the trypsin-like proteinases was found to be approximately 12 and 60 times higher compared to bovine trypsin at 37 degrees C and 1-3 degrees C, respectively. All three fractions of trypsin-like proteinases showed a carboxypeptidase activity in combination with their trypsin activity.

Animals↗