Successful implantation of cardiac defibrillators without induction of ventricular fibrillation using upper limit of vulnerability testing.

INTRODUCTION: Conventionally, the implantable cardioverter-defibrillator (ICD) is tested at implantation by measurement of defibrillation threshold (DFT), which involves repeated induction of ventricular fibrillation (VF). We report our data on successful ICD implantation without VF induction using a modified upper limit of vulnerability (ULV) testing method, compared to standard DFT testing. METHODS: Fourteen patients underwent ICD implantation using a modified ULV testing method by delivering a 15 J shock during the vulnerable period on the peak of the T wave, and if VF was not induced 15 J shocks were repeated at -20 and -40 msec before the peak of T wave. Failure to induce VF, indicating a ULV <15 joules (J), suggested a DFT < or =20 J based on previous studies demonstrating a close correlation (+/-5 J) between ULV and DFT. If VF was induced, a 20 J rescue shock was delivered. ICD therapy was then programmed on the basis of ULV testing. All patients underwent pre-discharge DFT testing to confirm adequate DFT. RESULTS: Using a modified ULV testing method, ICD implantation was completed without induction of VF in 8 patients and only a single episode of VF in 6 patients. The mean number of VF episodes (0.42 +/- 0.5) induced with ULV testing was significantly lower (p <.001) than the number induced during DFT testing (3.9 +/- 0.8). Pre-discharge DFT testing did not alter ICD programming in any patient. During follow-up of 14.85 +/- 12.31 months, three patients had seven episodes of VT/VF, six of whom were converted with the programmed first-shock strength, while one required a second high-energy shock to convert. This patient had a pre-discharge DFT of 10 joules. CONCLUSIONS: Successful ICD implantation can be safely performed with no or fewer episodes of VF induction using a modified ULV testing method.

Aged↗

Inappropriate implantable cardioverter defibrillator discharge from sensing of external alternating current leak.

Implantable cardioverter defibrillators (ICDs) are now an accepted and effective therapy for treatment of survivors of sudden cardiac death (SCD) and prevention of SCD in high-risk patients. Normal ICD function and delivery of therapy depends on appropriate sensing and detection of myocardial electrical potentials. Electromagnetic interference resulting in ICD malfunction is a well-documented phenomenon, however, there are less well-known external sources of interference, which may cause life threatening ICD malfunction. We report a unique case of repeated inappropriate ICD shocks in a ten-year old boy caused by the ICD sensing alternating current from an unexpected external source.

Child↗

Atrial Flutter.

Atrial flutter (AFl) is an arrhythmia resulting from reentry in a macroreentrant circuit, most commonly in the right atrium. Typical AFl uses the narrow isthmus of right atrial tissue between the tricuspid valve annulus and the inferior vena cava orifice as part of the macroreentrant circuit. The treatment of AFl is directed toward achieving the following four goals. 1) In the presence of AFl, adequate rate control is required, which can be achieved in most but not all patients by oral or intravenous digoxin, calcium channel blockers, or beta-blockers, alone or in combination. 2) Anticoagulation with warfarin should be considered in patients with recurrent AFl, especially those over 70 years of age, and those with a history of atrial fibrillation, stroke, or structural heart disease. 3) Conversion to sinus rhythm can be achieved in up to 70% of patients with intravenous ibutilide, but this should be reserved for patients with either normal hearts or only mild left ventricular dysfunction. Direct-current cardioversion is nearly 100% effective and is ideal for patients with left ventricular dysfunction. 4) Long-term maintenance of sinus rhythm may be achieved in up to 50% to 60% of patients by using antiarrhythmic drugs, including sotalol, amiodarone, dofetilide, propafenone, and flecainide, but with the potential for causing significant proarrhythmia and side effects. Radiofrequency catheter ablation may cure over 90% of patients with type 1 AFl (using the tricuspid valve to inferior vena cava isthmus), and from 70% to 90% of patients with atypical AFl. Newer mapping techniques, such as electroanatomic mapping, are likely to further reduce procedure time and improve success rates.

Journal Article↗