Publications and source records attributed to Ashraf M Mahmoud.

7 recordsLinked to original sources

Simulation of machine-specific topographic indices for use across platforms.

PURPOSE: The objective of this project is to simulate the current published topographic indices used for the detection and evaluation of keratoconus to allow their application to maps acquired from multiple topographic machines. METHODS: A retrospective analysis was performed on 21 eyes of 14 previously diagnosed keratoconus patients from a single practice using a Tomey TMS-1, an Alcon EyeMap, and a Keratron Topographer. Maps that could not be processed or that contained processing errors were excluded from analysis. Topographic indices native to each of the three devices were recorded from each map. Software was written in ANSI standard C to simulate the indices based on the published formulas and/or descriptions to extend the functionality of The Ohio State University Corneal Topography Tool (OSUCTT), a software package designed to accept the input from many corneal topographic devices and provide consistent display and analysis. Twenty indices were simulated. Linear regression analysis was performed between each simulated index and the corresponding native index. A cross-platform comparison using regression analysis was also performed. RESULTS: All simulated indices were significantly correlated with the corresponding native indices (p < 0.01), with a mean R of 0.84, ranging from 0.42 to 0.99. Cross-platform comparisons were nonsignificant for specific indices and devices. CONCLUSION: Topographic indices native to three devices were successfully simulated. Cross-platform comparisons may be limited for specific indices.

Computer Simulation↗

Response of the posterior corneal surface to laser in situ keratomileusis for myopia.

PURPOSE: To describe the response of the posterior corneal surface in laser in situ keratomileusis (LASIK) and determine whether residual stromal bed thickness or treatment magnitude is predictive of the posterior corneal surface elevation after uneventful LASIK. SETTING: A private hospital-based refractive surgery practice, Hong Kong SAR, China. METHODS: Orbscan I (Bausch & Lomb) videokeratography examinations were performed on 1124 patients before and 6 months after LASIK for myopia (mean -6.81 diopters [D] +/- 2.52 [SD]; range -0.88 to -14.50 D). The best-fit sphere (BFS) over the central 9.0 mm region of the posterior corneal surface before and after treatment was compared. The location and magnitude of the 1.0 mm diameter region of highest elevation above the BFS for the central 4.0 mm diameter zone were calculated before and after treatment and compared using a paired t test. Stepwise regression was used to model the best predictors of the posterior radius of the BFS and the central elevation of the corneal surface above the BFS before and after treatment. RESULTS: The mean radius of curvature of the posterior surface BFS decreased 0.10 mm after LASIK, from 6.31 to 6.21 mm (P<.001). Elevation above this BFS was increased 10 microm within a 1.00 mm diameter region of interest, and this was correlated with postoperative corneal thickness, inferotemporal decentration of the highest point, residual myopia, and steeper central posterior radius of curvature. CONCLUSIONS: No eye was diagnosed with corneal ectasia at the time of the 6-month postoperative visit. After LASIK, there was a decreased radius of curvature for the BFS of the posterior corneal surface, with the highest elevation point located paracentrally. These findings are similar to the anterior corneal surface changes observed in corneal ectasia after LASIK but smaller in magnitude.

Adolescent↗

Prediction of flap response.

PURPOSE: To find predictors of the induced biomechanical and optical effects of lamellar flap creation on the cornea. SETTING: Optimed Eye and Laser Clinic, Pretoria, South Africa, and the Department of Ophthalmology and Biomedical Engineering Center, The Ohio State University, Columbus, Ohio, and Bausch & Lomb Vision Research Laboratory, Rochester, New York, USA. METHODS: This prospective study monitored the refractive, wavefront aberration, and corneal topographic changes in 29 eyes of 15 patients for 3 months after the creation of a corneal lamellar flap. The main outcome measures for statistical analysis were refraction, total corneal thickness, residual corneal bed thickness, horizontal white-to-white corneal diameter, horizontal flap diameter, topography data, and wavefront data. RESULTS: Statistically significant changes were seen in the autorefraction mode. Wavefront data showed significant change in 4 Zernike modes-90/180-degree astigmatism, vertical coma, horizontal coma, and spherical aberration. The topography data indicated the corneal biomechanical response was significantly predicted by stromal bed thickness in the early follow-up period and by total corneal pachymetry and flap diameter in a 2-parameter statistical model in the late follow-up period. CONCLUSIONS: Uncomplicated lamellar flap creation is responsible for systematic changes in corneal topography and induction of higher-order optical aberrations. Predictors of this response include stromal bed thickness, flap diameter, and total corneal pachymetry.

Adult↗

Topographic and biomechanical differences between hyperopic and myopic laser in situ keratomileusis.

PURPOSE: To evaluate the size, shape, and uniformity of the videokeratographic functional optical zone (FOZ) after laser in situ keratomileusis (LASIK) in 2 cohorts of patients with equivalent amounts of preoperative myopic or hyperopic astigmatism. SETTING: Pepose Vision Institute, St. Louis, Missouri, USA. METHODS: Eyes with myopic or hyperopic astigmatism (n=27 in each group) that had LASIK with the Visx Star S3 laser were retrospectively selected to match for level of preoperative refractive error. Slit-scanning videokeratography was performed preoperatively and 6 months postoperatively and analyzed using custom software. The FOZ was calculated by analyzing refractive power maps using a region-growing algorithm. Difference maps were generated from slit images and compared for interval change in corneal elevation, tangential curvature, and refractive power. The difference maps were also averaged (mean difference maps) for each target population. A Zernike decomposition of corneal first-surface elevation was performed to compare postoperative values with baseline parameters. RESULTS: The mean postoperative refractive sphere at 6 months was -0.17 diopter (D) +/- 0.66 (SD) and +0.25 +/- 0.85 D in the myopia group and hyperopia group, respectively, and the mean postoperative astigmatism, -0.49 +/- 0.32 D and -0.65 +/- 0.52 D, respectively (P=.11). Based on the refractive power maps, the mean preoperative and postoperative myopic FOZ was 33.09 +/- 7.30 mm(2) and 30.94 +/- 5.43 mm(2), respectively, and the mean hyperopic FOZ, 33.19 +/- 7.96 mm(2) and 37.99 +/- 6.88 mm(2), respectively. After LASIK, there was an increase in magnitude of negative anterior corneal surface spherical-like Zernike values in the myopia group (P<.0001) and an increase in magnitude of positive spherical-like Zernike values in the hyperopia group. Postoperatively, significant induction of corneal surface horizontal coma was noted in hyperopic eyes (P<.0001). Hyperopic eyes, on average, had larger topographic FOZs after LASIK, but with less uniformity of curvature and power change than myopic eyes. CONCLUSIONS: Hyperopic LASIK, which involves more transition points along the ablation diameter, produced a less uniform topographic FOZ than typical myopic treatments. Less predictable biomechanical changes from the circumferential release of tension on collagen bundles after midperipheral hyperopic ablation and greater variation in beam centration and the angle of incidence may contribute to the greater variability in corneal curvature and power in hyperopic LASIK than in myopic LASIK.

Astigmatism↗

Model for nonectatic increase in posterior corneal elevation after ablative procedures.

PURPOSE: To evaluate the response of the posterior cornea after uneventful laser in situ keratomileusis (LASIK) with scanning-slit videokeratography using the change in elevation as a measure of biomechanical remodeling. SETTING: Hong Kong Sanatorium and Hospital, Hong Kong, China. METHODS: Three schematic models of possible posterior corneal response mechanisms to laser refractive surgery were proposed: model A, isolated central bulging; model B, forward shift over a large region of the posterior surface; model C, backward peripheral movement into the anterior chamber. A retrospective study was performed to determine which model was consistent with posterior corneal behavior in 2380 eyes of 1255 patients after myopic LASIK performed with the Technolas 217 laser (Bausch & Lomb). Patients received preoperative and 6-month postoperative Orbscan I (version 2.0, Bausch & Lomb) examinations. Preoperative posterior elevation maps were subtracted from postoperative maps of 2380 eyes using 3 fitting protocols. Difference maps were averaged and the results compared to the proposed schematic models. All topography data processing was done using the Ohio State University Corneal Topography Tool. RESULTS: Significant central increases in posterior elevation corresponded with significant peripheral decreases in posterior elevation. This pattern is consistent with schematic model C, backward peripheral movement of the posterior cornea, possibly due to a differential pattern of swelling. CONCLUSIONS: Increases in central posterior corneal elevation after LASIK appear to be dominated by backward peripheral corneal swelling into the anterior chamber rather than forward "bulging" of the central posterior cornea. This is consistent with stable remodeling of the corneal shape due to a surgically induced change in structure and fluid balance, rather than an ectatic event.

Astigmatism↗

Repeatability of corneal topography measurement in keratoconus with the TMS-1.

PURPOSE: The purpose of this study was to report the test-retest variability of simulated indices derived from the TMS-1 topography instrument (Tomey Technology, Waltham, MA) in keratoconus subjects enrolled in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study. METHODS: Four images were taken at an initial visit and at a repeat visit several weeks later. From these images, 17 indices were simulated from published formulas. Mixed-model analysis was used on test-retest data from the TMS-1 videokeratography instrument during the baseline year. This analysis yields estimates of within- and between-visit variability. RESULTS: Repeatability analysis revealed that within-visit standard errors were 1.0 to 5.9 times greater in keratoconus eyes than in normal controls when two images were analyzed from each visit. These values changed only slightly when more images were used. The ratio of between-visit standard errors of the indices were nearly equally greater than normal controls for (0.9-4.6 and 0.9-4.3) two images per eye and all images per eye, respectively. CONCLUSIONS: These results suggest that the repeatability of simulated indices derived from TMS-1 topography in keratoconus subjects is poorer than in normal controls.

Algorithms↗

Automated decision tree classification of corneal shape.

PURPOSE: The volume and complexity of data produced during videokeratography examinations present a challenge of interpretation. As a consequence, results are often analyzed qualitatively by subjective pattern recognition or reduced to comparisons of summary indices. We describe the application of decision tree induction, an automated machine learning classification method, to discriminate between normal and keratoconic corneal shapes in an objective and quantitative way. We then compared this method with other known classification methods. METHODS: The corneal surface was modeled with a seventh-order Zernike polynomial for 132 normal eyes of 92 subjects and 112 eyes of 71 subjects diagnosed with keratoconus. A decision tree classifier was induced using the C4.5 algorithm, and its classification performance was compared with the modified Rabinowitz-McDonnell index, Schwiegerling's Z3 index (Z3), Keratoconus Prediction Index (KPI), KISA%, and Cone Location and Magnitude Index using recommended classification thresholds for each method. We also evaluated the area under the receiver operator characteristic (ROC) curve for each classification method. RESULTS: Our decision tree classifier performed equal to or better than the other classifiers tested: accuracy was 92% and the area under the ROC curve was 0.97. Our decision tree classifier reduced the information needed to distinguish between normal and keratoconus eyes using four of 36 Zernike polynomial coefficients. The four surface features selected as classification attributes by the decision tree method were inferior elevation, greater sagittal depth, oblique toricity, and trefoil. CONCLUSION: Automated decision tree classification of corneal shape through Zernike polynomials is an accurate quantitative method of classification that is interpretable and can be generated from any instrument platform capable of raw elevation data output. This method of pattern classification is extendable to other classification problems.

Cornea↗