A self-contained polymeric 2-DE chip system for rapid and easy analysis.

We developed a polymeric 2-DE chip system. The chip consisted of an IEF region, an SDS-PAGE region, a valveless connection port, and a sample introduction port. A "junction structure" as a valveless connection port, which allowed separating and connecting the first- and second-dimensional gels, was fabricated between their regions. A "solution inlet" as a sample introduction port was fabricated to perform the liquid and sample introductions without solution leakage. Simultaneous sample monitoring was performed using the on-chip detection system. The performances of the system were demonstrated using commercially available proteins as a standard specimen and tissue-extracted proteins as the real samples. All procedures were employed without any movement of relocation part. This new 2-D separation system realized improved labor-intensive operations and a reduced experimental time.

Animals↗

Electron transfer mediator micro-biosensor fabrication by organic plasma process.

We propose a new strategy for constructing a mediator-type biosensor as a Bio-MicroElectroMechanical Systems (BioMEMS) application. A vinylferrocene plasma-polymerized film (PPF) was deposited directly onto the surface of an electrode under dry conditions. The resulting redox film was extremely thin, adhered well onto a substrate (electrode), and had a highly crosslinked network structure. This technique, capable of polymeric deposition of any kind of monomer, can also serve the purpose of anti-fouling coating, or layer-to-layer interface creation. With a subsequent plasma process, additional polymeric layer of hydrophilic acetonitrile was superimposed onto the existing vinylferrocene-PPF surface to offer crucial features such that the wettability could be adjusted for a better electron transfer, and amino functional groups could be attached to immobilize a large amount of enzyme. Based upon this scheme, the device fabrication could be designed in a manner that the whole procedure was made up of dry wafer-handling processes, which is compatible with mass production. A prototype device was fabricated to have an array of needle-shaped amperometric micro-biosensors. The resultant thin polymer layer carried a large number of the mediator molecules, accomplishing a lower overpotential (+410 mV) and a rapid response time (<5s). Stressing the advantages of the plasma polymerization process together with some additional features accomplished in our device fabrication, we would discuss new possibilities in the field of BioMEMS.

Biosensing Techniques↗

Organic plasma process for simple and substrate-independent surface modification of polymeric BioMEMS devices.

A polymeric bio micro electromechanical systems (BioMEMS) device was fabricated using organic plasma polymerization, by which the surface of a polymeric substrate could easily be modified through vapor-phase deposition of organic thin films. This technique, capable of polymeric deposition of any kind of monomer, can serve the purpose of anti-fouling coating, wettability control, or layer-to-layer interface creation, on the surface of any given chemically-inert polymeric substrate without involving cumbersome surface organic reactions. A prototype device was fabricated to have an array of electrochemical glucose biosensors with the three electrode configuration, each of which has a microfluidic channel (500 microm x 800 microm) for capillary-action-driven sample delivery and the concerned enzymatic reaction. Stressing the advantages of the plasma polymerization process using a polymeric substrate together with some additional features accomplished in our device fabrication, new possibilities in the field of polymeric BioMEMS are discussed.

Biosensing Techniques↗

Electrochemical protein chip with arrayed immunosensors with antibodies immobilized in a plasma-polymerized film.

An electrochemical protein chip was microfabricated. A thin-film three-electrode system, including an array of 36 platinum working electrodes, a set of thin-film Ag/AgCl electrodes, and platinum auxiliary electrodes, was integrated on a glass substrate. Capture antibodies were immobilized in a 4.5-nm-thick double layer of a hexamethyldisiloxane plasma-polymerized film. Because of their highly cross-linked network structure, the capture antibodies could be firmly immobilized. No nonspecific adsorption was observed during a series of procedures to detect target proteins, and electrochemical cross talk between neighboring sites was negligible. The sandwich immunoassay was conducted on a single chip using model proteins, alpha-1-fetoprotein and beta2-microglobulin. A distinct current increase following the oxidation of hydrogen peroxide produced by the enzymatic reaction of glucose oxidase was observed, which indicates that the capture proteins could actually bind the target proteins. Two kinds of protein were detected independently on multiple sites with respective capture antibodies.

Antibodies↗

Application of plasma-polymerized films for isoelectric focusing of proteins in a capillary electrophoresis chip.

The first use of plasma polymerization technique to modify the surface of a glass chip for capillary isoelectric focusing (cIEF) of different proteins is reported. The electrophoresis separation channel was machined in Tempax glass chips with length 70 mm, 300 microm width and 100 microm depth. Acetonitrile and hexamethyldisiloxane monomers were used for plasma polymerization. In each case 100 nm plasma polymer films were coated onto the chip surface to reduce protein wall adsorption and minimize the electroosmotic flow. Applied voltages of 1000 V, 2000 V and 3000 V were used to separate mixtures of cytochrome c (pI 9.6), hemoglobin (pI 7.0) and phycocyanin (pI 4.65). Reproducible isoelectric focusing of each pI marker protein was observed in different coated capillaries at increasing concentration 2.22-5 microg microL(-1). Modification of the glass capillary with hydrophobic HMDS plasma polymerized films enabled rapid cIEF within 3 min. The separation efficiency of cytochrome c and phycocyanin in both acrylamide and HMDS coated capillaries corresponded to a plate number of 19600 which compares favourably with capillary electrophoresis of neurotransmitters with amperometric detection.

Animals↗