Large-area phase-contrast X-ray imaging using a two-crystal X-ray interferometer.

Large-area (25 x 20 mm) phase-contrast X-ray imaging was attained by using a skew-symmetric two-crystal X-ray interferometer. The sub-nrad angular control required to operate the X-ray interferometer was achieved with a sleeve bearing and a feedback-positioning system. As a demonstration, measurements of a phase map of a rat's liver and a phase-contrast tomographic three-dimensional image of a piece of a rabbit's liver were performed at the Photon Factory using 0.07 nm synchrotron radiation X-rays.

Animals↗

Phase-contrast X-ray imaging based on interferometry.

Phase-contrast X-ray imaging including tomographic configuration using a crystal X-ray interferometer is reviewed. The imaging principle based on phase retrieval is described, and some demonstrations showing its high sensitivity are presented on the observations of animal and human cancerous tissues.

Animals↗

Vessel imaging by interferometric phase-contrast X-ray technique.

BACKGROUND: Phase-contrast x-ray imaging using an x-ray interferometer has great potential to reveal the structures inside soft tissues, because the sensitivity of this method to hydrogen, carbon, nitrogen, and oxygen is approximately 1000 times higher than that of the absorption-contrast x-ray method. Imaging of vessels is very important to understand the vascular distribution of organs and tumors, so the possibility of selective angiography based on phase contrast is examined with a physiological material composed of low-atomic-number elements. METHODS AND RESULTS: Phase-contrast x-ray imaging was performed with a synchrotron x-ray source. Differences in refractive index, ddelta, of physiological saline, lactated Ringer's solution, 5% glucose, artificial blood such as pyridoxylated hemoglobin-polyoxyethylene conjugate, and perfluorotributylamine were measured. Because the ddelta of physiological saline has highest contrast, it was used for the phase-contrast x-ray imaging of vessel, and this was compared with absorption-contrast x-ray images. Vessels >0.03 mm in diameter of excised liver from rats and a rabbit were revealed clearly in phase-contrast x-ray imaging, whereas the vessel could not be revealed at all by the absorption-contrast x-ray image. Absorption-contrast x-ray images with iodine microspheres depicted only portal veins >0.1 mm in diameter with nearly the same x-ray dose as the present phase-contrast x-ray imaging. CONCLUSIONS: Phase-contrast x-ray imaging explored clear depiction of the vessels using physiological saline with small doses of x-rays.

Angiography↗

[Phase-contrast x-ray imaging with x-ray interferometer for medical applications].

Phase-contrast x-ray imaging with x-ray interferometer can depict the minute difference within the biological object, and its sensitivity is about 1000 times higher than that of absorption-contrast method. For biomedical use of this technique, a large monolithic x-ray interferometer and 2 crystal interferometer having a field of view with 25 mm x 25 mm is being developed. Phase-contrast x-ray CT could reveal detail structures within tumor and surrounded tissue, and the vessel imaging of rat liver is also possible using physiological saline at 17.7 keV x-ray energy. Recently, human breast tissues were imaged at 35 keV and the contrast of image was much better than usual absorption contrast x-ray image obtained at 17.7 keV energy.

Animals↗