Implantable cardioverter defibrillator therapy in patients with ischemic or non-ischemic cardiomyopathy and nonsustained ventricular tachycardia.

BACKGROUND: Mortality benefit from implantable cardioverter defibrillator (ICD) therapy in ischemic cardiomyopathy (ICM) with non-sustained ventricular tachycardia (NS-VT) and inducible VT is well defined. Although NS-VT may suggest an increased risk of sudden cardiac death (SCD) in non-ischemic cardiomyopathy (NICM), the role of ICD therapy is unclear. This retrospective study compares follow-up data in these two groups after ICD implantation. METHODS: 153 consecutive patients with ICD implantation for NS-VT were analyzed. ICM patients received an ICD if they had inducible VT at electrophysiology study (EPS). NICM patients did not routinely undergo EPS before ICD implantation. RESULTS: There were 48 patients (33 males) in NICM group and 105 patients (89 males) in the ICM group. Baseline characteristics including mean ejection fraction (EF), distribution in various New York Heart Association (NYHA) classes, and the mean duration of follow up in the two groups were similar. 50% of the patients in the NICM group and 36% in the ICM group received appropriate therapies (p = 0.106). The mean number of appropriate therapies in the two groups were similar (23.3 +/- 56.7 and 22.5 +/- 59.5 respectively, p = NS). The percentage of patients with inappropriate therapies in the two groups were 27% and 23% respectively (p = NS). Patients in the NICM group received appropriate ICD discharges at a greater rate (p = 0.02). CONCLUSION: Patients undergoing ICD implantation for NICM and NS-VT receive appropriate ICD therapy at a greater rate than those implanted for ICM, NS-VT, and a positive EPS. Although these data do not prove survival benefit in NICM, they suggest a beneficial effect.

Adult↗

Does device-based testing save time during automatic implantable cardioverter-defibrillator implantation?

BACKGROUND: Defibrillation testing can be done either via an external cardiac defibrillator or directly via the implanted defibrillator during implantation (device-based testing). The advantage of one testing methodology over the other has not been adequately studied. METHODS AND RESULTS: Seventy-four patients (72% men) were randomized into two groups depending on the defibrillation testing methodology used--external cardiac defibrillation and device-based testing groups. R-wave, pacing threshold, pacing impedance, defibrillation threshold, defibrillation pathway impedance and total procedure time were not significantly different between the two groups. CONCLUSIONS: Device-based testing did not significantly reduce the procedure time. Lead and defibrillation parameters were similar in both the groups; lead repositioning and replacement were required in three patients in the external cardiac defibrillation group.

Aged↗