PubMed Health⌕ Search

Biomedical subjects

Augusto Panà

Publications and source records attributed to Augusto Panà.

At least 19 recordsLinked to original sources

Analysis of the shift of the transmission pattern for hepatitis C in a community in Central Italy.

Anti-HCV and HCV-RNA prevalence among adults from an isolated Central Italian community were 16.3% and 9.0%; 3.0%, 2.3% among 25-to-49-year-olds, 27.6%, 14.7% among older subjects. 1b genotype prevailed (88.5%). 1a, la/1b, 4 were also isolated. Seropositivity was associated with age > 50 years, public dental health care, glass syringe use, surgical interventions. The transmission pattern seems to be shifting from that typical of Southern Italy (high prevalence, particularly in the elderly, 1b genotype predominant, various routes of transmission involved, cohort effect), to that typical of Europe (lower prevalence, particularly among younger adults, other genotypes involved, association with intravenous drug use and immigrants).

Adult↗

Nucleotide correlation between HAV isolates from human patients and environmental samples.

Hepatitis A disease is endemic in Albania even though records from the Medical Authority show outbreaks involving only limited numbers of people. In the city of Lac, 200 people became ill following an outbreak of hepatitis A started on November 2002. The age distribution of the cases shows a peak in the age group 5-9 (43.5%) followed by the age group 10-14 (28%) and the age group 1-4 (18%). No cases were recorded in the age group 0-1. Drinking water and sewage samples were collected, using electropositive cartridges, during the outbreak. Rotavirus was identified by RT-PCR in two out of five drinking water samples; however, all the samples tested negative for HAV and astrovirus. Rotavirus was also identified in three out of five sewage samples from which four were HAV positive. HAV-RNA was identified in 28 (62.2%) out of 45 IgM anti-HAV positive sera collected during the outbreak. Genotype IA was expressed from all the amplified samples. Sequence analysis of the overlapping VP1-2A region shows 97-99% homology with three Italian strains IT-SCH-00, IT-ZAM-01, and IT-CAP-00 and one Spanish strain (Sa 30/06/95), whereas the phylogenetic tree built from the 168 bp sequence of the VP1-2A shows four clusters, one including 24 out of 28 RT-PCR positive sera. Considering the deduced amino acid sequence, only one substitution was identified and reported previously for genotype IB.

Adolescent↗

[Compulsory and additional parameters in water control].

The authors have analyzed 22 water samples from the Arno River (both river and drinking samples), as well as 11 effluent samples from an urban plant. Chemical and microbiological features of river samples were in line with the A3 class, needing treatment for drinking use (Executive Order n. 152/99); drinkable water met requirements (Presidents Decree n degrees 236/1988 and Executive Order n degrees 31/2001). As regards chemical parameters, effluents complied with the law (Executive Order n. 152/1999) but their bacteriological figures exceeded the standards set by the Authorities due to a lack in chlorination. Enteric viruses reacted to the RT-PCR test in 5 of the samples, including a Coxsackievirus Type B2 and a Poliovirus. No association was shown between bacteriophage parameters and virus.

English Abstract↗

[Application of quality standards to activities at the Advanced School of Hygiene and Preventive Medicine of Rome (Tor Vergata University): early results].

In the academic year 2001-2002, experts from the Advanced School of Hygiene and Preventive Medicine of Rome (Tor Vergata University) have tested a quality approach based on the ISO standards 9000:2000. In so doing, they have questioned the school's didactic organization itself. In order to assess such approach, students were given pre-course and post-course schedules, reflecting 38% and 61% of correct answers respectively. The popularity rating was set at 8.3 out of 10, and the survey has shown that quality standards can well be applied to the activities of the school.

Curriculum↗

[Effectiveness of the maintenance operations on the air conditioning systems of a university building in relation to the microbiological quality of the air indoor].

The microbiological quality of the air indoor is influenced from various factors and one of the most important is represented from the maintenance of the conditioning systems. In this study it has been estimated the effectiveness of an intervention of cleaning and maintenance on the systems of conditioning of an university building executing sampling before and after such intervention. The two results were confronted and it is observed as the maintenance of the air conditioners has influenced on the quality of the air indoor.

Air Conditioning↗