Aviv Amirav

Publications and source records attributed to Aviv Amirav.

8 recordsLinked to original sources

Flow modulation comprehensive two-dimensional gas chromatography-mass spectrometry with a supersonic molecular beam.

A new approach of flow modulation comprehensive two-dimensional gas chromatography-mass spectrometry (GC x GC-MS) with supersonic molecular beam (SMB) and a quadrupole mass analyzer is presented. Flow modulation uniquely enables GC x GC-MS to be achieved even with the limited scan speed of quadrupole MS, and its 20 ml/min column flow rate is handled, splitless, by the SMB interface. Flow modulation GC x GC-SMB-MS shares all the major benefits of GC x GC and combines them with GC-MS including: (a) increased GC separation capability; (b) improved sensitivity via narrower GC peaks; (c) improved sensitivity through reduced matrix interference and chemical noise; (d) polarity and functional group sample information via the order of elution from the second polar column. In addition, GC x GC-SMB-MS is uniquely characterized by the features of GC-MS with SMB of enhanced and trustworthy molecular ion plus isotope abundance analysis (IAA) for improved sample identification and fast fly-through ion source response time. The combination of flow modulation GC x GC with GC-MS with SMB (supersonic GC-MS) was explored with complex matrices such as diesel fuel analysis and pesticide analysis in agricultural products.

Chromatography, Gas↗

A simple and inexpensive "solvent in silicone tube extraction" approach and its evaluation in the gas chromatographic analysis of pesticides in fruits and vegetables.

A novel, simple, and inexpensive approach to sorptive extraction, which we call solvent in silicone tube extraction (SiSTEx), was applied to pesticide residue analysis and its effectiveness and efficiency were evaluated. In SiSTEx, which is a form of open tubular sorptive extraction, a piece of silicone tubing (4 cm long, 1.47 mm ID, 1.96 mm OD in this study) is attached to the cap of a 20 mL glass vial that contains the aqueous sample. The tubing is plugged at the end dangling in the sample solution, and MeCN (e.g., 40 microL) added by syringe to the inner tube volume through a septum in the cap. A stir-bar is used to mix the sample for a certain time (e.g., 60 min), which allows chemicals to partition into the tubing where they diffuse across the silicone and partition into the MeCN. The final MeCN extract is then analyzed for the concentrated analytes. In this study, the SiSTEx approach was evaluated for the analysis of organophosphorus (OP) and organochlorine (OC) pesticides in fruits and vegetables using GC/pulsed flame photometric (PFPD) and halogen specific (XSD) detectors for analysis. The produced samples were initially extracted by a rapid MeCN procedure, and 5 mL of the initial extract was diluted four-fold with water to undergo sorptive extraction for 60 min. The final extract was analyzed by GC/PFPD + XSD for 14 OP and 22 OC pesticides. This simple approach was able to detect 26 of the 36 pesticides at 10 ng/g or less original equivalent sample concentration with average reproducibility of 11% RSD. For those 26 pesticides, a 44-fold lower detection limit on average was achieved in matrix extracts using SiSTEx despite the four-fold dilution with water.

Journal Article↗

Isotope abundance analysis methods and software for improved sample identification with supersonic gas chromatography/mass spectrometry.

We present newly developed isotope abundance analysis (IAA) methods and software which are used to derive elemental formula information from experimental mass spectral data of molecular ion isotopomeric abundances. The software, using a novel method, can also be used to automatically confirm or reject NIST library search results, thereby significantly improving the confidence level in sample identifications. In the case of IAA confirmation of the NIST library results, sample identification is unambiguous, since the confirmation is achieved by two independent sets of data and analytical methods. In the case of a rejection, such as when the molecule is not included in the library's databases, the IAA software independently provides a list of elemental formulae with declining order of matching to the isotopomeric experimental data, in a similar way to accurate mass measurements with costly instruments. IAA is ideally applicable to gas chromatography/mass spectrometry (GC/MS) (and liquid chromatography/electron ionization mass spectrometry (LC/EI-MS)) with a supersonic molecular beam (SMB) since it requires a trustworthy and highly abundant true molecular ion that is unique to the SMB-MS systems, plus the absence of self chemical ionization and vacuum background noise, again unique features of GC/SMB-MS. The various features of the IAA methods and software are described, their performance is demonstrated with the analysis of experimental GC-SMB-MS data and the IAA concept is compared with accurate mass alternatives. The combination of IAA and GC/SMB-MS is believed to be superior to accurate mass GC/MS in view of the general availability of trustworthy molecular ions for an extended range of compounds.

Journal Article↗

A spray-based method for the production of semiconductor nanocrystals.

We present a spray based-method for the formation and production of semiconductor nanocrystals that provides an attractive alternative to the commonly used epitaxial and colloidal procedures. According to this spray-based method, mainly thermospray, solutions of semiconductor salts are first sprayed into monodispersed droplets, which subsequently become solid nanocrystals by solvent evaporation. A semiconductor nanocrystal is produced from a single spray droplet upon the full vaporization of the solvent. The average diameter and size distribution of the final nanocrystals are controlled and determined by the solute concentration of the sprayed solution and by the droplet size, hence by the spray production parameters. The spray-produced nanocrystals are collected on any selected solid support. Representative results, shown in this letter, reveal the formation of CdS nanocrystals in the size range of 3 to 6 nanometers and with a size distribution of as low as five percent. A further structural analysis of these nanocrystals showed that they were formed in the zinc blend phase with a high degree of crystallinity.

Letter↗

Identification of novel synthetic organic compounds with supersonic gas chromatography-mass spectrometry.

Several novel synthetic organic compounds were successfully analyzed with a unique type of GC-MS titled Supersonic GC-MS following a failure in their analysis with standard GC-MS. Supersonic GC-MS is based on interfacing GC and MS with a supersonic molecular beam (SMB) and on electron ionization of sample compounds as vibrationally cold molecules while in the SMB, or by cluster chemical ionization. The analyses of novel synthetic organic compounds significantly benefited from the extended range of compounds amenable to analyses with the Supersonic GC-MS. The Supersonic GC-MS enabled the analysis of thermally labile compounds that usually degrade in the GC injector, column and/or ion source. Due to the high carrier gas flow rate at the injector liner and column these compounds eluted without degradation at significantly lower elution temperatures and the use of fly-through EI ion source eliminated any sample degradation at the ion source. The cold EI feature of providing trustworthy enhanced molecular ion (M+), complemented by its optional further confirmation with cluster CI was highly valued by the synthetic organic chemists that were served by the Supersonic GC-MS. Furthermore, the provision of extended mass spectral structural, isomer and isotope information combined with short (a few minutes) GC-MS analysis times also proved beneficial for the analysis of unknown synthetic organic compounds. As a result, the synthetic organic chemists were provided with both qualitative and quantitative data on the composition of their synthetic mixture, and could better follow the path of their synthetic chemistry. Ten cases of such analyses are demonstrated in figures and discussed.

Gas Chromatography-Mass Spectrometry↗

Laser desorption combined with hyperthermal surface ionization time-of-flight mass spectrometry.

A setup combining laser desorption of nonvolatile molecules and their aerodynamic acceleration in a supersonic molecular beam followed by hyperthermal surface ionization in a reflectron time-of-flight mass spectrometer is described. While laser desorption performs the intact transfer of the analyte molecules into the gas phase, hyperthermal surface ionization opens up the possibility to efficiently ionize even larger molecules with a small and potentially controlled degree of fragmentation. Being an ionization technique, which is particularly effective for aromatic and heterocyclic compounds, the selectivity can further be increased by tuning the kinetic energy to which the molecules are accelerated in the supersonic beam. The results obtained for several polycyclic aromatic hydrocarbons and biochemical substances show that sufficient acceleration can be achieved even for molecules with a molecular weight above 5000 amu and that HSI preserves its advantageous features even for thermally labile large molecules such as insulin.

Journal Article↗

Extending the range of compounds amenable for gas chromatography-mass spectrometric analysis.

Gas chromatography-mass spectrometry (GC-MS) suffers from a major limitation in that an expanding number of thermally labile or low volatility compounds of interest are not amenable for analysis. We found that the elution temperatures of compounds from GC can be significantly lowered by reducing the column length, increasing the carrier gas flow rate, reducing the capillary column film thickness and lowering the temperature programming rate. Pyrene is eluted at 287 degrees C in standard GC-MS with a 30 m x 0.25 mm I.D. column with 1-microm DB5ms film and 1-ml/min He column flow rate. In contrast, pyrene is eluted at 79 degrees C in our "Supersonic GC-MS" system using a 1 m x 0.25 mm I.D. column with 0.1-microm DB5ms film and 100-ml/min He column flow rate. A simple model has been invoked to explain the significantly (up to 208 degrees C) lower elution temperatures observed. According to this model, every halving of the temperature programming rate, or number of separation plates (either through increased flow rate or due to reduced column length), results in approximately 20 degrees C lower elution temperature. These considerably lower elution temperatures enable the analysis of an extended range of thermally labile and low volatility compounds, that otherwise could not be analyzed by standard GC-MS. We demonstrate the analysis of large polycyclic aromatic hydrocarbons (PAHs) such as decacyclene with ten fused rings, well above the current GC limit of PAHs with six rings. Even a metalloporphirin such as magnesiumoctaethylporphin was easily analyzed with elution temperatures below 300 degrees C. Furthermore, a range of thermally labile compounds were analyzed including carbamates such as methomyl, aldicarb, aldicarbsulfone and oxamyl, explosives such as pentaerythritol tetranitrate, Tetryl and HMX, and drugs such as reserpine (608 a.m.u.). Supersonic GC-MS was used, based on the coupling of a supersonic molecular beam (SMB) inlet and ion sources with a bench-top Agilent 6890 GC plus 5972 MSD. The Supersonic GC-MS provides enhanced molecular ion without any ion source related peak tailing. Thus, the lower GC separation power involved in the analysis of thermally labile and low volatility compounds is compensated by increased separation power of the MS gained from the enhanced molecular ion. Several implications of these findings are discussed, including our conclusion that slower chromatography leads to better analysis of thermally labile compounds.

Gas Chromatography-Mass Spectrometry↗

Cluster chemical ionization for improved confidence level in sample identification by gas chromatography/mass spectrometry.

Upon the supersonic expansion of helium mixed with vapor from an organic solvent (e.g. methanol), various clusters of the solvent with the sample molecules can be formed. As a result of 70 eV electron ionization of these clusters, cluster chemical ionization (cluster CI) mass spectra are obtained. These spectra are characterized by the combination of EI mass spectra of vibrationally cold molecules in the supersonic molecular beam (cold EI) with CI-like appearance of abundant protonated molecules, together with satellite peaks corresponding to protonated or non-protonated clusters of sample compounds with 1-3 solvent molecules. Like CI, cluster CI preferably occurs for polar compounds with high proton affinity. However, in contrast to conventional CI, for non-polar compounds or those with reduced proton affinity the cluster CI mass spectrum converges to that of cold EI. The appearance of a protonated molecule and its solvent cluster peaks, plus the lack of protonation and cluster satellites for prominent EI fragments, enable the unambiguous identification of the molecular ion. In turn, the insertion of the proper molecular ion into the NIST library search of the cold EI mass spectra eliminates those candidates with incorrect molecular mass and thus significantly increases the confidence level in sample identification. Furthermore, molecular mass identification is of prime importance for the analysis of unknown compounds that are absent in the library. Examples are given with emphasis on the cluster CI analysis of carbamate pesticides, high explosives and unknown samples, to demonstrate the usefulness of Supersonic GC/MS (GC/MS with supersonic molecular beam) in the analysis of these thermally labile compounds. Cluster CI is shown to be a practical ionization method, due to its ease-of-use and fast instrumental conversion between EI and cluster CI, which involves the opening of only one valve located at the make-up gas path. The ease-of-use of cluster CI is analogous to that of liquid CI in ion traps with internal ionization, and is in marked contrast to that of CI with most other standard GC/MS systems that require a change of the ion source.

Journal Article↗