PubMed Health⌕ Search

Biomedical subjects

Axel Eickhoff

Publications and source records attributed to Axel Eickhoff.

12 recordsLinked to original sources

Computer-assisted colonoscopy (the NeoGuide Endoscopy System): results of the first human clinical trial ("PACE study").

OBJECTIVES: Unsedated colonoscopy is an uncomfortable procedure for most patients. Discomfort during colonoscopy is largely related to looping of the colonoscope, which displaces the colon from its native configuration and stretches attachments to the mesentery. A novel computer-assisted colonoscope utilizes a fully articulated, computer-controlled insertion tube. On manual insertion of the colonoscope, the position and angle of the scope's tip are encoded into a computer algorithm. As the colonoscope is advanced, the computer directs each successive segment to take the same shape that the tip had at a given insertion depth. The insertion tube thus changes its shape at different insertion depths in a "follow-the-leader" manner. METHODS: This initial clinical trial with this novel colonoscopy system was designed as a prospective, nonrandomized, unblinded, feasibility study. Three physicians of varying levels of experience participated in the study. RESULTS: Eleven consecutive patients (seven men, four women, age range 19-80) meeting inclusion criteria for screening or diagnostic colonoscopy were enrolled in the study. The cecum was reached in 10 consecutive patients (100%). Findings included diverticular disease in two cases and multiple colonic polyps in two cases. Postprocedure assessment at discharge, 48 h, and 30 days revealed no complications or adverse effects. Physician satisfaction and patient acceptance of this new technique were high. CONCLUSIONS: In this limited, first of its kind feasibility study, the computer-assisted colonoscope was shown to perform colonoscopy safely and effectively. The colonoscope's unique design limited loop formation during colonoscopy. Large-scale clinical trials are indicated.

Adult↗

Diagnosis of obscure gastrointestinal bleeding by intra-operative enteroscopy in 81 consecutive patients.

AIM: To analyze the results and complications of intra-operative enteroscopy (IOE) by investigating a series of selected patients with bleeding suspected to originate from the small intestine. METHODS: Eighty-one patients (mean age: 65 years) including 40 males (49.4%) and 41 females (50.6%) with obscure gastrointestinal bleeding underwent IOE between 1990 and 2004. The patients were identified from a database and data were selected from the patients' charts retrospectively. All the patients had undergone at least one non-diagnostic esophagogastroduodenoscopy, colonoscopy, standard enteroscopy and a negative abdominal ultrasound scan before IOE. RESULTS: The median minimal hemoglobin level in the patients was 59 + 15 g/L and 72.8% of the patients required transfusion of packed erythrocytes previously. A bleeding source was detected in 68 (84%) of the patients during IOE. Angiodysplasiae were found in 44 patients (54.3%) and 9 patients (11.1%) were affected by ulcers in the small intestine. A tumor in the small intestine was detected in another 6 patients. The treatment consisted of argon-plasma-coagulation, surgical suture or limited resection in most of the patients. CONCLUSION: Intra-operative enteroscopy is still used for the diagnosis of suspected small bowel bleeding. Recent developments such as wireless capsule endoscopy and double balloon enteroscopy, may lead to the replacement of IOE in the future.

Adult↗

Bacteremia after diagnostic conventional laparoscopy and minilaparoscopy: a prospective study in 100 patients.

BACKGROUND/GOALS: Diagnostic laparoscopy under sedoanalgesia is a valuable tool in the work-up of liver diseases and is helpful as a staging procedure. The rate of bacteremia caused by this procedure is unknown, in particular when performed as minilaparoscopy. STUDY: A 100 consecutive patients having undergone diagnostic laparoscopy carried out either conventionally (group I, n=50) or as minilaparoscopy (group II, n=50) were prospectively enrolled in this study. Blood cultures were drawn before and within 5 minutes after the procedure. Risk factors for bacteremia were evaluated. RESULTS: Bacterial growth occurred in 4 blood cultures drawn immediately after laparoscopy. No patient developed fever or other signs of infection in the follow-up. Risk factors predisposing to bacteremia could not be identified. CONCLUSIONS: Conventional diagnostic laparoscopy under sedoanalgesia and minilaparoscopy are associated with a low rate of bacteremia as in diagnostic upper endoscopy.

Adult↗

Risk factors for symptomatic stone recurrence after transpapillary laser lithotripsy for difficult bile duct stones using a laser with a stone recognition system.

BACKGROUND: Laser-induced shock-wave lithotripsy (LISL) is successfully used for the treatment of difficult bile duct stones. The aim of this study was to assess the long-term risk for a symptomatic bile duct stone recurrence after LISL and to detect risk factors predicting recurrence. METHODS: Between 1993 and 2001, 80 patients with difficult bile duct stones were successfully treated by intracorporeal LISL through the papilla of Vater. Seventy-one of these patients [median age, 65.8 years; 51 women (71.8%)] were followed for a median (range) period of 58 (1-114) months. RESULTS: Eleven patients (15.5%) had a symptomatic stone recurrence. The median (range) period between laser lithotripsy and recurrence was 40 (5-85) months. The presence of a bile duct stenosis (P=0.032) and a body-mass index below 25 (P=0.025) were significantly associated with an increased risk for stone recurrence. A gallbladder in situ, the presence of gallbladder stones, dilation of the bile duct, or a peripapillary diverticulum was not associated with stone recurrence. CONCLUSIONS: The presence of a bile duct stenosis is significantly related to bile duct stone recurrence after treatment with LISL. The impact of the body mass index on stone recurrence is interesting. The gallbladder status did not predict stone recurrence in our study.

Aged↗

Colorectal polyps: detection with dark-lumen MR colonography versus conventional colonoscopy.

PURPOSE: To prospectively compare dark-lumen magnetic resonance (MR) colonography with conventional colonoscopy in the detection of colorectal polyps. MATERIALS AND METHODS: Local ethical committee approval and informed consent were obtained. One hundred consecutive patients (56 men, 44 women; mean age +/- standard deviation, 67.7 years +/- 14.7; range, 25-82 years) who were referred for conventional colonoscopy from January 2003 to January 2004 underwent MR colonography and conventional colonoscopy after standard precolonoscopic bowel cleansing. Colonoscopy was performed immediately after MR colonography. For MR colonography, the colon was filled with approximately 2000 mL of tap water. Imaging was performed with a 1.5-T MR unit with patients in the prone position. A T1-weighted three-dimensional volumetric interpolated breath-hold sequence was performed before and 75 seconds after intravenous administration of 0.2 mmol gadobenate dimeglumine per kilogram of body weight. Results of MR colonography were analyzed on a per-polyp and per-patient basis. Findings at colonoscopy were used as the reference for determining accuracy, sensitivity, specificity, and positive and negative predictive values of MR colonography. RESULTS: Of 100 patients recruited for study, 92 (52 men, 40 women; mean age, 61.5 years +/- 14.5; range, 25-82 years) underwent complete MR and conventional colonoscopy examinations. Forty-three of the 92 patients (47%) had normal findings at conventional colonoscopy. In the other 49 patients (53%), conventional colonoscopy depicted 107 polyps (82 adenomas, 25 hyperplastic polyps) and seven carcinomas. At per-polyp analysis, sensitivity of MR colonography in the detection of adenomatous polyps was 100% for polyps at least 10 mm in diameter and 84.2% for polyps 6-9 mm in diameter. At per-patient analysis, the accuracy of MR colonography was 93.1% (sensitivity, 89%; specificity, 96%) if detection of adenomatous polyps of all sizes was considered. CONCLUSION: Dark-lumen MR colonography is a promising modality with high accuracy for detecting colorectal polyps larger than 5 mm in diameter.

Adult↗

A prospective two-center study comparing wireless capsule endoscopy with intraoperative enteroscopy in patients with obscure GI bleeding.

BACKGROUND: Capsule endoscopy enables noninvasive diagnostic examination of the entire small intestine. However, sensitivity and specificity of capsule endoscopy have not been adequately defined. We, therefore, compared capsule endoscopy by using intraoperative enteroscopy as a criterion standard in patients with obscure GI bleeding. METHODS: Forty-seven consecutive patients with obscure GI bleeding (11 with ongoing overt bleeding, 24 with previous overt bleeding, and 12 with obscure-occult bleeding) from two German gastroenterologic centers were included. All patients who had a prior nondiagnostic evaluation, including upper endoscopy, colonoscopy with a retrograde examination of the distal ileum, and push enteroscopy, underwent capsule endoscopy followed by intraoperative enteroscopy. RESULTS: Capsule endoscopy identified lesions in 100% of the patients with ongoing overt bleeding, 67% of the patients with previous overt bleeding, and 67% of the patients with obscure-occult bleeding. Angiectasias were the most common source of bleeding (n = 22). Capsule endoscopy showed the source of bleeding in 74.4% of all patients. The method was more effective in patients with ongoing bleeding. Compared with intraoperative enteroscopy sensitivity, specificity, and positive and negative predictive values of capsule endoscopy were 95%, 75%, 95%, and 86%, respectively. CONCLUSIONS: Capsule endoscopy has high sensitivity and specificity to detect a bleeding source in patients with obscure GI bleeding. Thus, wireless capsule endoscopy can be recommended as part of the routine work-up in patients with obscure GI bleeding.

Adolescent↗

Diagnosis of liver cirrhosis: a comparison of modified ultrasound and laparoscopy in 100 consecutive patients.

BACKGROUND/GOALS: Liver cirrhosis, the final stage of chronic liver disease, is characterized by an unfavorable prognosis and an increased risk of hepatocellular carcinoma and also requires an appropriate management. Laparoscopy, the gold standard in the diagnosis of cirrhosis, is hampered by its invasiveness. Therefore, a noninvasive method for diagnosing liver cirrhosis would be of great benefit. STUDY: A consecutive series of 100 patients, sent to our gastroenterological unit for diagnostic laparoscopy, underwent a standardized ultrasonographic examination prior to laparoscopy. RESULTS: Conventional ultrasonographic examination revealed a sensitivity of 55% and a specificity of 86% in the diagnosis of cirrhosis. Considering the assessment of the transmission of heart pulsation on the liver surface, the corresponding values improved by increasing to 85% and 93%. CONCLUSION: Evaluating the transmission of heart pulsation on the liver surface improves the ability of ultrasound to diagnose liver cirrhosis; therefore, it should be an integral part of routine sonographic examination of the liver.

Adult↗

Endoscopic stenting for postoperative biliary strictures due to hepatic hydatid disease: effectiveness and long-term outcome.

BACKGROUND: Postoperative strictures due to hepatic hydatid disease caused by Echinococcus surgery is considered to be a rare cause of benign bile duct strictures, especially in the Western world. GOALS: The aim of this retrospective study is to demonstrate possible characteristics of the strictures as well as the effectiveness of long-term endoscopic stenting. STUDY: Between 1994 and 2001, we treated 10 of these cases in our clinic. All patients had surgery for hepatic Echinococcus disease one or more times. These types of benign biliary strictures, secondary to surgery of hepatic hydatid disease, were multiple and located in the proximal common bile duct. Endoscopic stent therapy was carried out in all cases containing transpapillary approach with plastic prostheses (7.5-11 French) or transhepatic approach with Yamakawa prostheses (16 French). Nine patients were available for follow-up. RESULTS: In 6 patients (66%), the stents were removed after a median period of 22.5 months with radiologic and clinical signs of improvement. Three patients required prolonged dilatation therapy because of stricture-recurrence. There was low overall morbidity and we recognized no therapy-associated mortality. CONCLUSIONS: Endoscopic stent therapy is a safe nonoperative method for the treatment of postoperative benign biliary strictures due to hepatic hydatid disease.

Aged↗

Self-expanding metal stents versus plastic prostheses in the palliation of malignant dysphagia: long-term outcome of 153 consecutive patients.

BACKGROUND: Malignant dysphagia due to esophagogastric cancer is associated with poor overall prognosis. Placements of self-expandable metal stents or plastic tubes are established methods as palliative treatment options. As an alternative and/or complementary therapy, radiologic techniques (external beam radiation/brachytherapy) and locally endoscopic techniques (laser, APC-beamer, PDT) are often used. STUDY AND GOALS: Retrospective trial of 153 patients treated in our department between 1993 and 2001. Forty-five patients received a plastic tube (Group A) and 108 patients were treated with metal stents (Group B). Both groups were compared for improvement of dysphagia score, survival, recurrent dysphagia and complications. RESULTS: Stent placement was successful in 41 of 45 (93%) patients of Group A and 107 of 108 (99%) of Group B. The median dysphagia score improved significantly in Group A (from 3.03 to 1.55, P = 0.010) and Group B (from 2.77 to 1.44, P = 0.009). Recurrent dysphagia was noted in 12 of 45 (27%) patients of Group A and 27 of 108 (25%) patients of Group B. Median survival time after stent insertion was 78 days (Group A) and 113 days (Group B). Overall complications occurred in 15 of 45 (33%) patients of Group A and 28 of 108 (26%) patients of Group B. However, significantly (P = 0.05) more major complications were seen in Group A than in Group B (22% vs. 9%). CONCLUSIONS: Our results indicate a marginal clinical benefit for metal stents versus plastic tubes in malignant dysphagia in the long run. However, metal stents seem to be safer and associated with a prolonged improvement of dysphagia score.

Adenocarcinoma↗