PubMed Health⌕ Search

Biomedical subjects

Axel Haase

Publications and source records attributed to Axel Haase.

At least 19 recordsLinked to original sources

Assessment of inhibitory potency of antibiotics by MRI: apparent T2 as a marker of cell growth.

A new method to assess the antibiotic potency by MRI has been developed. Correlating 1H NMR spectra of bacterial cultures with the extracellular parameters T2, OD600, and pH, a relationship between cell growth and T2 variations was established. T2 is influenced by chemical exchange that depends on pH, composition, and concentration of the medium. Changes in the medium from bacterial metabolism are reflected in alternating T2 values. At 17.6 T, growth curves based on T2 values were measured simultaneously of several cultures of Streptococcus vestibularis. From T2 growth curves in the presence of varying concentrations of vancomycin, the minimum inhibitory concentration of the antibiotic could be determined to be 0.33+/-0.08 microM. This value was in good agreement with the result obtained by the conventional broth microdilution. In principle, T2 growth curves can be determined on a large number of cultures simultaneously and may potentially be used as a novel tool in high through-put screening of novel anti-infective substances.

Anti-Bacterial Agents↗

In vivo quantitative three-dimensional motion mapping of the murine myocardium with PC-MRI at 17.6 T.

This work presents a method that allows for the assessment of 3D murine myocardial motion in vivo at microscopic resolution. Phase-contrast (PC) magnetic resonance imaging (MRI) at 17.6 T was applied to map myocardial motion in healthy mice along three gradient directions. High-resolution velocity maps were acquired at three different levels in the murine myocardium with an in-plane resolution of 98 mum, a slice thickness of 0.6 mm, and a temporal resolution of 6 ms. The applied PC-MRI method was validated with phantom experiments that confirmed the correctness of the method with deviations of <1.7%. Myocardial in-plane velocities between 0.5 cm/s and 2.2 cm/s were determined for the healthy murine myocardium. Through-plane velocities of 0.1-0.83 cm/s were measured. Velocity data was also used to calculate the myocardial twist angle during systole at different slices in the short-axis view.

Algorithms↗

Improved cardiac sodium MR imaging by density-weighted phase-encoding.

PURPOSE: To show that density-weighted (DW) k-space sampling improves the quality of human cardiac sodium imaging, a novel method was implemented that combines the high signal-to-noise efficiency of three-dimensional phase-encoding with the advantageous localization performance of nonuniform sampling. A simulation demonstrates substantially reduced blood contamination in the myocardium. MATERIALS AND METHODS: At 2.0 T, DW cardiac "fast" sodium images with a voxel size of 844 microL in seven minutes and "high-resolution" scans in 30 minutes with a voxel size of 570 microL were acquired. For comparison, conventional gradient-echo imaging was also performed. RESULTS: In the DW images, a myocardial signal-to-noise ratio (SNR) of 16.0 in the left ventricle and 8.5 in the septum (N = 4) was measured. With longer experimental duration (about 30 minutes; N = 3), the image quality and the SNR could be further improved (voxel size: 570 microL; SNR: blood 16.1, septum 10.6). Compared to the gradient-echo images, the image quality was substantially improved. CONCLUSION: This new method for human cardiac sodium imaging provides high image quality combined with optimal sensitivity and thus may improve the clinical applicability of 23Na cardiac MRI.

Computer Simulation↗

In vivo assessment of absolute perfusion and intracapillary blood volume in the murine myocardium by spin labeling magnetic resonance imaging.

The absolute perfusion and the intracapillary or regional blood volume (RBV) in murine myocardium were assessed in vivo by spin labeling magnetic resonance imaging. Pixel-based perfusion and RBV maps were calculated at a pixel resolution of 469 x 469 mum and a slice thickness of 2 mm. The T(1) imaging module was a segmented inversion recovery snapshot fast low angle shot sequence with velocity compensation in all three gradient directions. The group average myocardial perfusion at baseline was determined to be 701 +/- 53 mL (100 g . min)(-1) for anesthesia with isoflurane (N = 11) at a mean heart rate (HR) of 455 +/- 10 beats per minute (bpm). This value is in good agreement with perfusion values determined by invasive microspheres examinations. For i.v. administration of the anesthetic Propofol, the baseline perfusion decreased to 383 +/- 40 mL (100 g . min)(-1) (N = 17, P < 0.05 versus. isoflurane) at a mean heart rate of 261 +/- 13 bpm (P < 0.05 versus isoflurane). In addition, six mice with myocardial infarction were studied under isoflurane anesthesia (HR 397 +/- 7 bpm). The perfusion maps showed a clear decrease of the perfusion in the infarcted area. The perfusion in the remote myocardium decreased significantly to 476 +/- 81 mL (100 g . min)(-1) (P < 0.05 versus sham). Regarding the regional blood volume, a mean value of 11.8 +/- 0.8 vol % was determined for healthy murine myocardium under anesthesia with Propofol (N = 4, HR 233 +/- 17 bpm). In total, the presented techniques provide noninvasive in vivo assessment of the perfusion and the regional blood volume in the murine myocardium for the first time and seem to be promising tools for the characterization of mouse models in cardiovascular research.

Analysis of Variance↗

Experimental autoimmune encephalomyelitis in the rat spinal cord: lesion detection with high-resolution MR microscopy at 17.6 T.

BACKGROUND AND PURPOSE: Experimental autoimmune encephalomyelitis (EAE) is an inflammatory demyelinating disorder of the CNS and an animal model of multiple sclerosis. We used high-field MR microscopy at 17.6 T to image spinal cord inflammatory lesions in the acute stage of chronic relapsing rat EAE. We sought to compare lesions detected on MR imaging with histopathologic findings and to quantify the inflammatory lesion load. METHODS: Imaging of fixed spinal cord specimens was performed by using a 3D gradient-echo sequence with a spatial resolution of 35 x 35 x 58 microm3 and a total imaging time of 5.5 hours. Histopathologic analysis was performed by staining axial sections with hematoxylin-eosin or Luxol fast blue to identify cellular infiltration and demyelination. RESULTS: Clinical signs of EAE occurred on days 10-14 after immunization. On day 22, healthy white matter and gray matter were differentiated by high contrast on T2*-weighted images, with white matter lesions appearing as hyperintense areas in the normal-appearing white matter. Inflammatory lesions identified on histopathologic evaluation were readily detected with MR imaging and vice versa. MR imaging and histopathologic analysis had excellent correlation regarding the extent of white matter lesions. Inflammatory infiltrates of gray matter were not detectable with MR imaging. Using a semiautomatic segmentation of the acquired MR data, we could quantify white matter lesion load. CONCLUSION: Ex vivo high-resolution MR microscopy of the spinal cord at 17.6 T allows rapid and highly accurate determination of CNS inflammation by demonstrating virtually all histologically detectable white matter inflammatory lesions.

Animals↗

Inversion recovery TrueFISP: quantification of T(1), T(2), and spin density.

A novel procedure is proposed to extract T(1), T(2), and relative spin density from the signal time course sampled with a series of TrueFISP images after spin inversion. Generally, the recovery of the magnetization during continuous TrueFISP imaging can be described in good approximation by a three parameter monoexponential function S(t) = S(stst)(1-INV exp(-t/T(*) (1)). This apparent relaxation time T(*) (1) <or= T(1) depends on the flip angle as well as on both T(1) and T(2). Here, it is shown that the ratio T(1)/T(2) can be directly extracted from the inversion factor INV, which describes the relation of the signal value extrapolated to t = 0 and the steady-state signal. Analytical expressions are given for the derivation of T(1), T(2), and relative spin density directly from the fit parameters. Phantom results show excellent agreement with single point reference measurements. In human volunteers T(1), T(2), and spin density maps in agreement with literature values were obtained.

Algorithms↗

Impact of hypoxia and the metabolic microenvironment on radiotherapy of solid tumors. Introduction of a multi-institutional research project.

BACKGROUND: Recent developments in imaging technology and tumor biology have led to new techniques to detect hypoxia and related alterations of the metabolic microenvironment in tumors. However, whether these new methods can predict radiobiological hypoxia and outcome after fractionated radiotherapy still awaits experimental evaluation. MATERIAL AND METHODS: The present article will introduce a multi-institutional research project addressing the impact of hypoxia and the metabolic microenvironment on radiotherapy of solid tumors. The four laboratories involved are situated at the universities of Dresden, Mainz, Munich and Würzburg, Germany. RESULTS: The joint scientific project started to collect data obtained on a set of ten different human tumor xenografts growing in nude mice by applying various imaging techniques to detect tumor hypoxia and related parameters of the metabolic microenvironment. These techniques include magnetic resonance imaging and spectroscopy, metabolic mapping with quantitative bioluminescence and single-photon imaging, histological multiparameter analysis of biochemical hypoxia, perfusion and vasculature, and immunohistochemistry of factors related to angiogenesis, invasion and metastasis. To evaluate the different methods, baseline functional radiobiological data including radiobiological hypoxic fraction and outcome after fractionated irradiation will be determined. CONCLUSION: Besides increasing our understanding of tumor biology, the project will focus on new, clinically applicable strategies for microenvironment profiling and will help to identify those patients that might benefit from targeted interventions to improve tumor oxygenation.

Animals↗

Myocardial perfusion measurements by spin-labeling under different vasodynamic states.

In this study absolute myocardial perfusion was determined using a spin-labeling magnetic resonance imaging (MRI) technique at 2 Tesla. The technique was applied to 16 healthy volunteers at resting conditions, adenosine-induced stress, and oxygen breathing. Overall myocardial quantitative perfusion was determined as 2.3 +/- 0.8 mL/g/min (rest), 4.2 +/- 1.0 mL/g/min (adenosine), and 1.6 +/- 0.6 mL/g/min (oxygen), respectively. T1 of left ventricular blood pool decreased from 1709 +/- 101 ms (rest) to 1423 +/- 61 ms (oxygen), whereas T1 of right ventricular blood did not change significantly (1586 +/- 126 ms and 1558 +/- 150 ms). In conclusion, the presented technique for quantification of myocardial perfusion is an alternative to contrast agent-based methods. The spin labeling method is noninvasive and easily repeatable and it could therefore become an important tool to study changes in myocardial perfusion under different vasodynamic states.

Adenosine↗

Cardiac hypertrophy is associated with decreased eNOS expression in angiotensin AT2 receptor-deficient mice.

Angiotensin II receptors play an essential role in cardiovascular physiology and disease. The significance of angiotensin type II (AT2) receptors in cardiac disease still remains elusive. Thus, we tested in gene-targeted mice whether AT2 receptors modulate cardiac function and remodeling after experimental myocardial injury. To generate myocardial infarcts of reproducible size, a cryolesion was generated at the free wall of the left ventricle of wild-type mice (Agtr2+/Y) and mice carrying a deletion of the AT2 receptor gene (Agtr2-/Y). Postinjury remodeling was followed up for 4 weeks after cryoinjury. The cryoprocedure led to an increased heart weight/body weight ratio and heart weight/tibia length ratio in AT2-deficient mice compared with control mice. Morphometric analysis revealed a significant increase in myocyte cross-sectional area after cardiac injury (infarct vs sham Agtr2+/Y, +53%; vs Agtr2-/Y, +95%). Expression of endothelial nitric oxide synthase (eNOS) was significantly lower in hearts from Agtr2-/Y than from Agtr2+/Y mice. eNOS downregulation was accompanied by a decrease in cardiac cGMP levels in Agtr2-/Y mice. In isolated murine cardiomyocytes, angiotensin II induced eNOS expression through AT2 receptors, and inhibition of NO production by NG-nitro-l-arginine methyl ester abolished the antihypertrophic effect of AT2 on cardiac myocytes. Our results demonstrate in a genetic mouse model that angiotensin II AT2 receptors exert an antihypertrophic effect in cardiac remodeling after myocardial cryoinjury and link the expression of cardiac eNOS to AT2 receptor activation.

Animals↗

Chronic coronary artery stenosis induces impaired function of remote myocardium: MRI and spectroscopy study in rat.

Our purpose was to study morphological, functional, and metabolic changes induced by chronic ischemia in myocardium supplied by the stenotic vessel and in the remote area by MR techniques. A new technique of image fusion is proposed for analysis of coronary artery stenosis involving coronary MR angiography and spectroscopic imaging. Cine-MRI was performed 2 wk after induction of coronary stenosis. Global heart function and regional wall thickening were determined in 11 Wistar rats with stenosis and compared with 7 control rats. Two weeks after stenosis was induced, spin-labeling MRI for measurement of perfusion was performed in 14 isolated hearts. In eight isolated hearts with coronary stenosis, MR spectroscopy was performed, followed by angiography. 31P metabolite maps were fused with three-dimensional coronary angiograms. Induction of stenosis led to reduced segmental wall thickening (control: 75 +/- 9%, ischemic region: 9 +/- 3%, P < 0.05 vs. control) but also to impaired function of the remote region and lower cardiac output. Perfusion was reduced by 74.9 +/- 4.0% within ischemic segments compared with a septal control region. The phosphocreatine (PCr)/ATP ratio as a marker of ischemia was reduced in the region associated with stenosis (1.09 +/- 0.09) compared with remote (1.27 +/- 0.08) and control hearts (1.43 +/- 0.08; P < 0.05). The histological fraction of fibrosis within the ischemic region (12.8 +/- 1.4%) correlated to ATP signal reduction from remote to the ischemic region (r = 0.71, P < 0.05), but not to reduced wall thickening. Coronary narrowing caused declining function accompanied by diminished PCr/ATP, indicating impaired energy metabolism. Neither decline of function nor PCr signal decline correlated to fraction of fibrosis in histology. In contrast, reduction of ATP correlated to fibrosis and therefore to loss of viability. Impaired function within the ischemic region is associated with decreased PCr. Function of the remote region was affected as well. The fusion of PCr metabolite maps and the coronary angiogram may help to assess coronary morphology and resulting metabolic changes simultaneously.

Animals↗

In vivo assessment of absolute perfusion in the murine skeletal muscle with spin labeling MRI. Magnetic resonance imaging.

PURPOSE: To assess absolute perfusion in the skeletal muscle of mice in vivo with spin labeling magnetic resonance imaging (MRI) under normal and stress conditions. MATERIALS AND METHODS: Absolute perfusion in the skeletal muscle of 27 C57BL/6 mice was assessed in vivo non-invasively by spin labeling MRI at 7.05 T. This technique was based on the acquisition of T1 maps with global and slice-selective spin inversion in separate acquisitions. T1 mapping was performed by inversion recovery snapshot fast low angle shot imaging. To guarantee proper spin inversion within the whole mouse, a dedicated radiofrequency (RF) coil combination was constructed. A birdcage resonator was used for transmission, while detection of the MRI signal was achieved by a surface coil. RESULTS: Basal perfusion in the hindlimbs was determined to be 94 +/- 10 mL (100 g x minute)(-1) (mean +/- standard error of the mean [SEM], N = 27). This value is in good agreement with perfusion values determined by invasive techniques such as microspheres. A subgroup of six animals received a constant dose of 4 mg (kg x minute)(-1) of the vasodilator adenosine by an intraperitoneal catheter. In this case, perfusion was significantly increased to 179 +/- 56 mL (100 g x minute)(-1) (mean +/- SEM, N = 6, P < 0.02). Mean basal perfusion in this subgroup was 96 +/- 26 mL (100 g x minute)(-1). CONCLUSION: Spin labeling MRI is a well-suited technique for the in vivo assessment of absolute perfusion in the murine skeletal muscle.

Adenosine↗

Quantitative assessment of myocardial perfusion with a spin-labeling technique: preliminary results in patients with coronary artery disease.

PURPOSE: To determine perfusion and coronary reserve in human myocardium without contrast agent using a spin labeling technique. MATERIALS AND METHODS: Assessment of myocardial perfusion is based on T1 measurements after global and slice-selective spin preparation. This magnetic resonance imaging (MRI) technique was applied to 12 healthy volunteers and 16 patients with suspected coronary artery disease under resting conditions and adenosine-induced vasodilatation. RESULTS: In volunteers, quantitative perfusion was calculated as 2.4 +/- 1.2 mL/g/minute (rest) and 3.9 +/- 1.3 mL/g/minute (adenosine), respectively. Perfusion reserve was 2.1 +/- 0.6. In patients, when comparing perfusion reserve in the anterior and posterior myocardium, reduced values according to a stenotic supplying vessel could be seen in seven of 11 patients who underwent stress testing. In these patients, the relative difference of coronary reserve was 44% +/- 18%. Two patients without stenosis of coronary arteries showed no differences in coronary reserve (with a relative change of 2 +/- 2%). CONCLUSION: In patients with single-vessel coronary artery disease, differences in coronary reserve were clearly detectable when comparing anterior and posterior myocardium. The spin labeling method is noninvasive and easily repeatable, and it could therefore become an important tool to study changes in myocardial perfusion.

Adenosine↗

In vivo time-resolved quantitative motion mapping of the murine myocardium with phase contrast MRI.

Myocardial motion of healthy mice and mice with myocardial infarction was assessed in vivo by phase contrast (PC) cine MRI. The imaging module was a segmented fast low angle shot (FLASH) sequence with velocity compensation in all three gradient directions. To accomplish additional motion encoding, the spin phase was prepared using bipolar gradient pulses, which resulted in a linear dependence between the voxel velocity and spin phase. This method provided accurate quantification of the velocity magnitude and direction of the murine myocardium at a spatial resolution of 234 microm and a temporal resolution of about 10 ms. The acquisition was EKG-gated and the mice were anesthetized by inhalation of 1.5-4.0 vol.% isoflurane at 1.5 l/min oxygen flow. To validate the MRI measurements, an experiment with a calibrated rotating phantom was performed. Deviations between MR velocity measurements and optical assessment by a light detector were lower than 1.6%. During our study, myocardial motion velocities between 0.4 cm/s and 1.7 cm/s were determined for the healthy murine myocardium across the heart cycle. Areas with myocardial infarction were clearly segmented and showed a motion velocity which was significantly reduced. In conclusion, the method is an accurate technique for the assessment of murine myocardial motion in vivo.

Animals↗

Visualization of myocardial microstructure using high-resolution T*2 imaging at high magnetic field.

The analysis of myocardial microstructure in vivo is important for the determination of myocardial contractility and function. The purpose of the present study was to demonstrate that high-resolution T*2 imaging has the potential to visualize the microstructure of beating, isolated rat hearts. To perform T*2 imaging, a multiple gradient-echo sequence was implemented on an 11.75 Tesla microscopy system. An in-plane resolution of 78 microm and a slice thickness of 250 microm were achieved in 24 min. In comparison to histological sections, the T*2 maps showed an excellent spatial correspondence to the myocardial fiber structure. To demonstrate the utility of this technique, morphologic alterations in myocardial microstructure were investigated in hearts with chronic myocardial infarction. Scar tissue and the extent of the infarcted region were clearly visualized and quantified using high-resolution T*2 imaging.

Animals↗

High-resolution MRI with cardiac and respiratory gating allows for accurate in vivo atherosclerotic plaque visualization in the murine aortic arch.

Genetically engineered mouse models provide enormous potential for investigation of the underlying mechanisms of atherosclerotic disease, but noninvasive imaging methods for analysis of atherosclerosis in mice are currently limited. This study aimed to demonstrate the feasibility of MRI to noninvasively visualize atherosclerotic plaques in the thoracic aorta in mice deficient in apolipoprotein-E, who develop atherosclerotic lesions similar to those observed in humans. To freeze motion, MR data acquisition was both ECG- and respiratory-gated. T(1)-weighted MR images were acquired with TR/TE approximately 1000/10 ms. Spatial image resolution was 49 x 98 x 300 micro m(3). MRI revealed a detailed view of the lumen and the vessel wall of the entire thoracic aorta. Comparison of MRI with corresponding cross-sectional histopathology showed excellent agreement of aortic vessel wall area (r = 0.97). Hence, noninvasive MRI should allow new insights into the mechanisms involved in progression and regression of atherosclerotic disease.

Animals↗

Time-resolved flow measurement in the isolated rat heart: characterization of left coronary artery stenosis.

The investigation of flow behavior in coronary arteries is of great importance for an understanding of heart failure and heart regulation mechanisms. The purpose of the present study was to demonstrate that flow velocity can be quantified in the coronary arteries of the isolated rat heart with high-resolution phase contrast MRI. A phase contrast cine-FLASH imaging sequence was used for flow quantification with an in-plane resolution of 70 microm and a slice thickness of 500 microm. With time-resolved measurements, coronary flow over the heart cycle was analyzed. Furthermore, the flow behavior in coronary stenosis was investigated and the degree of stenosis was quantified with MR phase contrast imaging. To achieve the required spatial resolution and a satisfactory signal-to-noise ratio, the experiments were performed at 11.75 T.

Animals↗