Simple linear formulation for magnetostimulation specific to MRI gradient coils.

A simple linear formulation for magnetostimulation thresholds specific to MRI gradient coils is derived based on established hyperbolic electrostimulation strength vs. duration relations. Thresholds are derived in terms of the gradient excursion required to cause stimulation, and it is demonstrated that the threshold curve is a linear function of the gradient switching time. A parameter beta is introduced as being fundamental in the evaluation of gradient coil stimulation. beta is a map of the induced electric field per unit gradient slew rate, and can be calculated directly from the gradient coil wire pattern. Consideration of beta alone is sufficient to compare stimulation thresholds between different gradient coil designs, as well as to evaluate the expected dependency of stimulation threshold on position within the gradient coil. The linear gradient threshold curve is characterized by two parameters: SR(min) and DeltaG(min). SR(min) is the slope of the threshold curve and represents the minimum slew rate required to cause stimulation in the limit of infinite gradient strength. DeltaG(min) is the vertical axis intercept of the curve and represents the minimum gradient excursion required to cause stimulation in the limit of infinite slew rate. Both SR(min) and DeltaG(min) are functions of both beta and the standard tissue parameters E(r) (rheobase) and tau(c) (chronaxie time). The ease with which both the gradient system performance and the stimulation thresholds can be plotted on the same axes is noted and is used to introduce the concept of a piece-wise linear operational limit curve for a gradient system.

Electric Stimulation↗

A comparison between human magnetostimulation thresholds in whole-body and head/neck gradient coils.

Gradient coil magnetostimulation thresholds were measured in a group of 20 volunteers in both a whole-body gradient coil and a head/neck gradient coil. Both coils were operated using both x and y axes simultaneously (xy oblique mode). The waveform applied was a 64-lobe trapezoidal train with 1-ms flat-tops and varying rise times. Thresholds were based on the subjects' perception of stimulation, and painful sensations were not elicited. Thresholds were expressed in terms of the total gradient excursion required to cause stimulation as a function of the duration of the excursion. Thresholds for each subject were fit to a linear model, and values for the threshold curve slope (SR(min)) and vertical axis intercept (DeltaG(min)) were extracted. For the body coil, the mean values were: SR(min) = 62.2 mT/m/ms, DeltaG(min) = 44.4 mT/m. For the head/neck coil, the mean values were: SR(min) = 87.3 mT/m/ms, DeltaG(min) = 78.9 mT/m. These curve parameters were combined with calculated values for the induced electric field as a function of position within the coil to yield the tissue specific parameters E(r) (electric field rheobase) and tau(c) (chronaxie). For tissue stimulated within the body coil, the mean values were: E(r) = 1.8 V/m, tau(c) = 770 micros. For tissue stimulated within the head/neck coil, the mean values were: E(r) = 1.3 V/m, tau(c) = 1100 micros. Scalar potential contributions were not included in the calculation of induced electric fields. The mean threshold curves were combined with the gradient system performance curves to produce operational limit curves. The operational limit curves for the head/neck coil system were verified to be higher than those of the whole-body coil; however, the head/neck system was also found to be physiologically limited over a greater range of its operation than was the body coil. Subject thresholds between the two coils were not well correlated.

Female↗

Gradient-induced acoustic and magnetic field fluctuations in a 4T whole-body MR imager.

Both the acoustic and magnetic fluctuation frequency response functions for a Siemens AS25 body gradient coil inside a 4 Tesla whole-body MR system were measured and analyzed in this study. In an attempt to correlate the acoustic noise inside the gradient coil with magnetic field oscillations, triangular and trapezoidal gradient impulses of varying amplitudes and widths were used to excite the gradient coil. The acoustic and magnetic responses to these inputs were measured. The results show the existence of discrete resonances in both acoustic and uniform magnetic field fluctuation spectra, while gradient magnetic field fluctuation spectra show no such resonances. In addition, the dominant amplitude peaks in spectra fluctuate similarly with respect to trapezoidal gradient impulse flat-top widths. This implies that these phenomena are correlated, and that the trapezoidal impulse flat-top width may be used as a way to suppress both acoustic noise and uniform magnetic field oscillations.

Electromagnetic Fields↗

Design and fabrication of a three-axis edge ROU head and neck gradient coil.

The design, fabrication, and testing of a complete three-axis gradient coil capable of imaging the human neck is described. The analytic method of constrained current minimum inductance (CCMI) was used to position the uniform region of the gradient coil adjacent to and extending beyond the physical edge of the coil. The average gradient efficiency of the three balanced axes is 0.37 mT/m/A and the average inductance is 827 microH. With maximum amplifier current of 200A and receive signal sweep width of +/-125 kHz, the average minimum FOV using this gradient set is 7.9 cm. The completed coil has an inner diameter of 32 cm, an outer diameter of 42 cm, and a length (including cabling connections) of 80 cm. The entire coil was built in-house. The structure is actively water cooled. Heating measurements were made to characterize the thermal response of the coil under various operating conditions and it was determined that a continuous current of 100A could be passed through all three axes simultaneously without increasing the internal coil temperature by more than 23 degrees C. Eddy current measurements were made for all axes. With digital compensation, the gradient eddy current components could be adequately compensated. A large B(o) eddy current field is produced by the Gz axis that could be corrected through the use of an auxiliary B(o) compensation coil. Preliminary imaging results are shown in both phantoms and human subjects.

Brain↗

Constrained length minimum inductance gradient coil design.

A gradient coil design algorithm capable of controlling the position of the homogeneous region of interest (ROI) with respect to the current-carrying wires is required for many advanced imaging and spectroscopy applications. A modified minimum inductance target field method that allows the placement of a set of constraints on the final current density is presented. This constrained current minimum inductance method is derived in the context of previous target field methods. Complete details are shown and all equations required for implementation of the algorithm are given. The method has been implemented on computer and applied to the design of both a 1:1 aspect ratio (length:diameter) central ROI and a 2:1 aspect ratio edge ROI gradient coil. The 1:1 design demonstrates that a general analytic method can be used to easily obtain very short gradient coil designs for use with specialized magnet systems. The edge gradient design demonstrates that designs that allow imaging of the neck region with a head sized gradient coil can be obtained, as well as other applications requiring edge-of-cylinder regions of uniformity.

Algorithms↗

Practical design of a high-strength breast gradient coil.

A high-strength three-axis local gradient coil set was constructed for MRI of the breast. Gradient fields with good uniformity (<10% deviation from the desired gradient) over most of the volume required for breast imaging were generated with efficiencies of up to 3.3 mT/m/A. The coils will allow diffusion breast imaging in clinically acceptable examination times. The electrical design, water cooling system, and fabrication techniques are described. Preliminary tests of the coil included images of a grid phantom and diffusion measurements in a short-T2 agarose gel phantom.

Artifacts↗

A novel transverse gradient coil design for high-resolution MR imaging.

The authors describe a new gradient coil design for high resolution human, animal, specimen, or phantom imaging with high gradient efficiency and a large region of excellent gradient uniformity. Important features of our new design are the simple analytical description of the wire patterns that comprise the design, and ease of construction. Wires are spaced in a sinusoidal distribution around the circumference of the cylinder, and curved in an arcsin shape along the length of the cylinder. This coil produces a magnetic field pointing in a direction transverse to the axis of the coil with a gradient in the direction parallel to the axis of the coil. The same arcsin coil can be used to create a magnetic field pointing in a direction parallel to its axis with a gradient in a direction perpendicular to the coil axis. A prototype coil was constructed; field and inductance calculations were verified. Geometric variations on this coil design were modeled and their performance characteristics compared. This coil design is ideal for rapid implementation of a transverse gradient coil, since no specialized design software is required.

Algorithms↗