A performance comparison of flat-panel imager-based MV and kV cone-beam CT.

The use of cone-beam computed tomography (CBCT) has been proposed for guiding the delivery of radiation therapy, and investigators have examined the use of both kilovoltage (kV) and megavoltage (MV) x-ray beams in the development of such CBCT systems. In this paper, the inherent contrast and signal-to-noise ratio (SNR) performance for a variety of existing and hypothetical detectors for CBCT are investigated analytically as a function of imaging dose and object size. Theoretical predictions are compared to the results of experimental investigations employing largearea flat-panel imagers (FPIs) at kV and MV energies. Measurements were performed on two different FPI-based CBCT systems: a bench-top prototype incorporating an FPI and kV x-ray source (100 kVp x rays), and a system incorporating an FPI mounted on the gantry of a medical linear accelerator (6 MV x rays). The SNR in volume reconstructions was measured as a function of dose and found to agree reasonably with theoretical predictions. These results confirm the theoretically predicted advantages of employing kV energy x rays in imaging soft-tissue structures found in the human body. While MV CBCT may provide a valuable means of correcting 3D setup errors and may offer an advantage in terms of simplicity of mechanical integration with a linear accelerator (e.g., implementation in place of a portal imager), kV CBCT offers significant performance advantages in terms of image contrast and SNR per unit dose for visualization of soft-tissue structures. The relatively poor SNR performance at MV energies is primarily a result of the low x-ray quantum efficiencies (approximately a few percent or less) that are currently achieved with FPIs at high energies. Furthermore, kV CBCT with an FPI offers the potential of combined volumetric and radiographic/fluoroscopic imaging using the same device.

Dose-Response Relationship, Radiation↗

Correction of scatter in megavoltage cone-beam CT.

The role of scatter in a cone-beam computed tomography system using the therapeutic beam of a medical linear accelerator and a commercial electronic portal imaging device (EPID) is investigated. A scatter correction method is presented which is based on a superposition of Monte Carlo generated scatter kernels. The kernels are adapted to both the spectral response of the EPID and the dimensions of the phantom being scanned. The method is part of a calibration procedure which converts the measured transmission data acquired for each projection angle into water-equivalent thicknesses. Tomographic reconstruction of the projections then yields an estimate of the electron density distribution of the phantom. It is found that scatter produces cupping artefacts in the reconstructed tomograms. Furthermore, reconstructed electron densities deviate greatly (by about 30%) from their expected values. The scatter correction method removes the cupping artefacts and decreases the deviations from 30% down to about 8%.

Artifacts↗

An iterative algorithm for reconstructing incident beam distributions from transmission measurements using electronic portal imaging.

The problem of reconstructing incident radiotherapy beam profiles from electronic portal images recorded behind a phantom is addressed. To this end an iterative algorithm is presented, which is able to extract the input beam profile from a portal image by compensating for the attenuation of the beam and subtracting the amount of scatter emitted by the phantom. The algorithm requires only a thickness map of the phantom. Scatter is estimated using a superposition method based on precalculated Monte Carlo scatter kernels. The method is tested for a homogeneous water-equivalent slab phantom for simple rectangular and complex multileaf collimated fields. It is shown that the method produces a stable result within four iterations yielding an accuracy for the incident beam distribution of better than 3%.

Algorithms↗

Tomotherapeutic portal imaging for radiation treatment verification.

In their tomotherapy concept Mackie and co-workers proposed not only a new technique for IMRT but also an appropriate and satisfactory method of treatment verification. This method allows both monitoring of the portal dose distribution and imaging of the patient anatomy during treatment by means of online CT. This would enable the detection of inaccuracies in dose delivery and patient set-up errors. In this paper results are presented showing that a single electronic portal imaging device (EPID) could deliver all data necessary to establish such a complete verification system for tomotherapy and even other IMRT techniques. Consequently it has to be shown that it is able to record both the low-intensity photon fluences encountered in tomographic imaging and the intense photon transmission of each treatment field. The detector under investigation is a video-based EPID, the BIS 710 (manufactured by Wellhöfer Dosimetrie, Schwarzenbruck, Germany). To examine the suitability of the BIS for CT at 6 MV beam quality, different phantoms were scanned and reconstructed. The agreement between a diamond detector and BIS responses is quantitative. Tomographic reconstruction of a complete set of these transmission profiles resulted in images which resolve 3 cm large objects having a (theoretical) contrast to water of less than 9%. Three millimetre objects with a 100% contrast are clearly visible. The BIS signal was shown to measure photon fluence distributions. The reconstructed images possess a spatial and contrast resolution sufficient for accurate imaging of the patient anatomy, needed for treatment verification in many clinical cases.

Data Interpretation, Statistical↗