Comparison of macular versus paramacular retinal sensitivity to femtosecond laser pulses.

Single 130 fs laser pulses in the near-IR (800 nm) were used to create ophthalmoscopically viewed minimum visible lesions (MVLs) within the macular and paramacular regions in rhesus monkey eyes. MVL thresholds at 1 and 24 h are reported as the 50% probability for damage (ED50) together with their fiducial limits at the 95% confidence level. These measured thresholds are compared with previously reported thresholds for near-IR and visible wavelengths for both macular and paramacular areas. Threshold doses were lower at the 24 h reading than at the 1 h reading for both retinal regions and the ED50s for the macula were slightly lower than for the paramacula. We measured the 24 h MVL ED50 thresholds to be 0.35 and 0.55 microJ for the macular and paramacular areas, respectively. The combined data for both areas yielded a threshold of 0.45 microJ.

Animals↗

Proposed maximum permissible exposure limits for ultrashort laser pulses.

Recent studies have provided considerable ED50 data for both visible and near infrared wavelengths from single laser pulses below one nanosecond of exposure. The current ANSI Z136.1 standard does not offer an approved maximum permissible exposure limit for subnanosecond single laser pulses and the current suggested maximum permissible exposure limit may be overly conservative. Lacking an approved standard industrial, medical, educational, and military uses of these types of laser systems may be limited or prohibited. A new set of laser maximum permissible exposure limits for subnanosecond visible and near infrared single laser pulses is recommended, along with the steps taken to develop the proposed standard.

Animals↗

Spectrally resolved white-light interferometry for measurement of ocular dispersion.

Spectrally resolved white-light interferometry was used to measure the wavelength dependence of refractive index (i.e., dispersion) for various ocular components. Verification of the technique's efficacy was substantiated by accurate measurement of the dispersive properties of water and fused silica, which have both been well-characterized in the past by single-wavelength measurement of the refractive index. The dispersion of bovine and rabbit aqueous and vitreous humors was measured from 400 to 1100 nm. In addition, the dispersion was measured from 400 to 700 nm for aqueous and vitreous humors extracted from goat and rhesus monkey eyes. An unsuccessful attempt was also made to use the technique for dispersion measurement of bovine cornea and lens. The principles of white-light interferometry, including image analysis, measurement accuracy, and limitations of the technique, are discussed. In addition, alternate techniques and previous measurements of ocular dispersion are reviewed.

Animals↗

Ultrashort laser pulse bioeffects and safety.

Recent studies of retinal damage due to ultrashort laser pulses have shown that less energy is required for retinal damage for pulses shorter than 1 ns than that for longer pulses. It has also been shown that more energy is required for near-infrared (NIR) wavelengths than in the visible because the light focuses behind the retina, requiring more energy to produce a damaging fluence on the retina. We review the progress made in determining the trends in retinal damage from laser pulses of 1 ns to 100 fs in the visible and NIR wavelength regimes. We have determined the most likely damage mechanism(s) operative in this pulse width regime.

Animals↗

Thresholds for visible lesions in the primate eye produced by ultrashort near-infrared laser pulses.

PURPOSE: To evaluate the effects of near-infrared (near-IR) ultrashort laser pulses on the retinas of rhesus monkey eyes and to perform threshold measurements for minimum visible lesions (MVLs) at pulse widths ranging from nanoseconds to femtoseconds. METHODS: Near-infrared single laser pulses were placed within the macular area of live rhesus monkey eyes for five different pulse widths (7 nsec; 80, 20, and 1 psec; and 150 fsec). One visible wavelength of 530 nm at 100 fsec was also included in the study. Visible lesion thresholds (MVL-ED50) were determined 1 hour and 24 hours after exposure. Fluorescein angiography thresholds (FAVL-ED50) were also determined using a probit analysis of the dosage. Thresholds were calculated as that dosage causing a 50% probability for damage, and the fiducial limits were calculated at the 95% confidence level. RESULTS: For all pulse widths, the 24-hour MVL-ED50 was lower than the 1-hour MVL-ED50, and they both decreased with decreasing pulse width. Thresholds at the 1-hour reading decreased from 28.7 microJ at 7 nsec to 1.8 microJ at 150 fsec, whereas thresholds at 24 hours decreased from 19.1 microJ at 7 nsec to 1.0 microJ at 150 fsec. The doubled 1060-nm wavelength of the 530-nm threshold decreased from 0.36 to 0.16 microJ after 24 hours. FAVL-ED50s were much higher than MVL-ED50s, showing that FA was not as sensitive in determining damage levels. CONCLUSIONS: Laser pulse widths less than 1 nsec in the near-IR are capable of producing visible lesions in rhesus monkey eyes with pulse energies between 5 and 1 microJ. Also, the near-IR thresholds for these pulse widths are much higher than for the visible wavelengths. As with visible wavelengths, FA is not as sensitive in determining threshold levels as is visually observing the retina through a fundus camera.

Animals↗

Longitudinal relaxation and diffusion measurements using magnetic resonance signals from laser-hyperpolarized 129Xe nuclei.

Methods for T1 relaxation and diffusion measurements based on magnetic resonance signals from laser-hyperpolarized 129Xe nuclei are introduced. The methods involve optimum use of the perishable hyperpolarized magnetization of 129Xe. The necessary theoretical framework for the methods is developed, and then the methods are applied to measure the longitudinal relaxation constant, T1, and the self-diffusion constant, D, of hyperpolarized 129Xe. In a cell containing natural abundance 129Xe at 790 Torr, the T1 value was determined to be 155 +/- 5 min at 20 degrees C and at 2.0 T field. For a second cell at 896 Torr, at the same field and temperature, the T1 value was determined to be 66 +/- 2 min. At a higher field of 7.05 T, the T1 values for the two cells were found to be 185 +/- 10 and 88 +/- 5 min, respectively. The 129Xe self-diffusion constant for the first cell was measured to be 0.057 cm2/ s and for the second cell it was 0.044 cm2/s. The methods were applied to 129Xe in the gas phase, in vitro; however, they are, in principle, applicable for in vivo or ex vivo studies. The potential role of these methods in the development of newly emerging hyper-polarized 129Xe MRI applications is discussed.

Animals↗

Pathology of macular lesions from subnanosecond pulses of visible laser energy.

PURPOSE: To demonstrate how current theories regarding ultrashort laser pulse effects may apply to ocular tissue, a prospective clinicopathologic study of macular lesions from ultrashort laser pulses compared the pathologic effects with the clinical and fluorescein angiographic appearance of the laser lesions. METHODS: Ninety-femtosecond, 3-picosecond, and 60-picosecond laser pulses, throughout a range of energies, were delivered to the retina of Macaca mulatta. Clinical examination and fluorescein angiography were performed at 1 hour in all eyes and 24 hours after exposure in selected eyes. Eyes were enucleated at 1 or 24 hours after lesion placement. The structure and extent of retinal lesions were scored for comparison with the clinical findings. RESULTS: Focal retinal pathologic appearance correlated well with a clinically visible lesion observed 24 hours after laser delivery. Retinal lesions were small foci of retinal pigment epithelium (RPE) and retinal disruption, without choriocapillaris involvement. Lesions that contained focal RPE vacuoles or lifting of the RPE also demonstrated leakage, in fluorescein angiographic studies. Suprathreshold laser delivery frequently caused focal columns of retinal injury and intraretinal hemorrhages from retinal vessel bleeding, with no rupture of choroidal blood vessels. CONCLUSIONS: The retinal response to ultrashort laser pulses at moderate energy followed a pattern of focal damage from laser-induced breakdown without significant thermal spread.

Animals↗

Digital integrated retinal surgical laser system.

The year is 2001--ophthalmic retinal surgery is now fully computer assisted. Patients arriving for scheduled treatments of diabetic retinopathy, retinal tears, or macular degeneration have their retina digitally mapped by a technician. From the retinal map, the ophthalmologist plots therapeutic lesion sites with a light pen on the computer screen that will automatically be placed by a computer controlled argon laser. The treatment only requires 100 ms per lesion placement thus reducing office calls to approximately 45 minutes freeing the ophthalmologist for other pressing cases. This paper reports on the development of a clinically significant prototype system that will help bring this scenario to fruition.

Animals↗

Retinal damage and laser-induced breakdown produced by ultrashort-pulse lasers.

BACKGROUND: In vivo retinal injury studies using ultra-short-pulse lasers at visible wavelengths for both rabbit and primate eyes have shown that the degree of injury to the retina is not proportional to the pulse energy, especially at suprathreshold levels. In this paper we present results of calculations and measurements for laser-induced breakdown (LIB), bubble generation, and self-focusing within the eye. METHODS: We recorded on video and measured the first in vivo LIB and bubble generation thresholds within the vitreous in rabbit and primate eyes, using external optics and femtosecond pulses. These thresholds were then compared with calculations from our LIB model, and calculations were made for self-focusing effects within the vitreous for the high peak power pulses. RESULTS: Results of our nonlinear modeling and calculations for self-focusing and LIB within the eye were compared with experimental results. The LIB ED50 bubble threshold for the monkey eye was measured and found to be 0.56 microJ at 120 fs, compared with the minimum visible lesion (MVL) threshold of 0.43 microJ at 90 fs. Self-focusing effects were found to be possible for pulsewidths below 1 ps and are probably a contributing factor in femtosecond-pulse LIB in the eye. CONCLUSIONS: Based on our measurements for the MVL thresholds and LIB bubble generation thresholds in the monkey eye, we conclude that in the femtosecond pulsewidth regime for visible laser pulses, LIB and self-focusing are contributing factors in the lesion thresholds measured. Our results may also explain why it is so difficult to produce hemorrhagic lesions in either the rabbit or primate eye with visible 100-fs laser pulses even at 100 microJ of energy.

Animals↗

Development of an integrated automated retinal surgical laser system.

Researchers at the University of Texas and the USAF Academy have worked toward the development of a retinal robotic laser system. The overall goal of this ongoing project is to precisely place and control the depth of laser lesions for the treatment of various retinal diseases such as diabetic retinopathy and retinal tears. Separate low speed prototype subsystems have been developed to control lesion depth using lesion reflectance feedback parameters and lesion placement using retinal vessels as tracking landmarks. Both subsystems have been successfully demonstrated in vivo on pigmented rabbits using an argon continuous wave laser. Preliminary testing on rhesus primate subjects have been accomplished with the CW argon laser and also the ultrashort pulse laser. Recent efforts have concentrated on combining the two subsystems into a single prototype capable of simultaneously controlling both lesion depth and placement. We have designated this combined system CALOSOS for Computer Aided Laser Optics System for Ophthalmic Surgery. Several interesting areas of study have developed in integrating the two subsystems: 1) "doughnut" shaped lesions that occur under certain combinations of laser power, spot size, and irradiation time complicating measurements of central lesion reflectance, 2) the optimal retinal field of view (FOV) to achieve both tracking and lesion parameter control, and 3) development of a hybrid analog/digital tracker using confocal reflectometry to achieve retinal tracking speeds of up to 100 dgs. This presentation will discuss these design issues of this clinically significant prototype system. Details of the hybrid prototype system are provided in "Hybrid Eye Tracking for Computer-Aided Retinal Surgery" at this conference. The paper will close with remaining technical hurdles to clear prior to testing the full-up clinical prototype system.

Animals↗

Ultrashort laser pulse effects in ocular and related media.

Relatively little experimental and theoretical data exist on the retinal hazards of ultrashort laser pulses operating in the visible and near infrared spectral regions. Because of potential nonlinear effects that can occur from high-peak irradiance, ultrashort laser pulses propagate from the cornea to the retina, we have developed four projects within our Ultrashort Pulse Effects program. First, we discuss preliminary ED50 threshold values for nanosecond (ns), picosecond (ps), and femtosecond (fs) single pulses for in-vivo ocular exposures in Dutch Belted Rabbits using pulses in the visible spectral region. Then we examine two experiments that study nonlinear absorption using water tubes and measure the nonlinear refractive index of ocular tissue using the Z-Scan technique. Finally, we determine laser-induced breakdown thresholds in ultrahigh purity water. These studies give reasonable estimates of the damage thresholds and insight into the biophysics of how ultrashort pulses interact with ocular media.

Animals↗

Porcine skin visible lesion thresholds for near-infrared lasers including modeling at two pulse durations and spot sizes.

With the advent of such systems as the airborne laser and advanced tactical laser, high-energy lasers that use 1315-nm wavelengths in the near-infrared band will soon present a new laser safety challenge to armed forces and civilian populations. Experiments in nonhuman primates using this wavelength have demonstrated a range of ocular injuries, including corneal, lenticular, and retinal lesions as a function of pulse duration. American National Standards Institute (ANSI) laser safety standards have traditionally been based on experimental data, and there is scant data for this wavelength. We are reporting minimum visible lesion (MVL) threshold measurements using a porcine skin model for two different pulse durations and spot sizes for this wavelength. We also compare our measurements to results from our model based on the heat transfer equation and rate process equation, together with actual temperature measurements on the skin surface using a high-speed infrared camera. Our MVL-ED50 thresholds for long pulses (350 micros) at 24-h postexposure are measured to be 99 and 83 J cm(-2) for spot sizes of 0.7 and 1.3 mm diam, respectively. Q-switched laser pulses of 50 ns have a lower threshold of 11 J cm(-2) for a 5-mm-diam top-hat laser pulse.

Animals↗