PubMed HealthSearch

Biomedical subjects

B A Weber

Publications and source records attributed to B A Weber.

12 recordsLinked to original sources

Application of an implantable bone conduction hearing device to patients with unilateral sensorineural hearing loss.

This investigation, comprised of five studies, was undertaken to determine if individuals with newly acquired profound unilateral hearing losses would benefit from an implantable bone-conduction hearing device. The bone conductor was implanted on the side of the deaf ear at the time of translabyrinthine acoustic tumor resection. Two areas greatly affected by unilateral hearing loss, speech recognition in noise and sound localization, were examined. No improvement in aided performance could be documented in either area.

Adult

Implantable bone-conduction hearing device: practical considerations.

An implantable bone conduction hearing device can be of significant benefit to carefully selected patients with noncorrectable conductive hearing losses. However, for some patients the device has significant limitations. This paper presents several practical issues that need to be considered before a decision is made regarding implant surgery. It is recommended that, whenever possible, air conduction hearing aids remain the first option considered when a patient's conductive hearing loss cannot be resolved through traditional medical management.

Adult

Comparative studies of speech processing strategies for cochlear implants.

A wide variety of speech processing strategies for multichannel auditory prostheses were compared in studies of two patients implanted with the UCSF electrode array. Each strategy was evaluated using tests of vowel and consonant confusions, with and without lipreading. Included among the strategies were the compressed analog processor of the present UCSF/Storz prosthesis and a group of interleaved pulses processors in which the amplitudes of nonsimultaneous pulses code the spectral variations of speech. For these patients, each with indications of poor nerve survival, test scores were significantly higher with the interleaved pulses processors. We believe this superior performance was a result of 1. the substantial release from channel interactions provided by nonsimultaneous stimuli and 2. a fast enough rotation among the channels to support adequate temporal and spectral resolution of perceived speech sounds.

Cochlear Implants

Auditory brain-stem response audiometry in children.

Auditory Brain-stem Response (ABR) Audiometry, also called Brain-stem Evoked Response Audiometry, is an effective procedure for assessing the hearing of children who cannot or will not perform satisfactorily on behavioral audiometric tests. Although ABR audiometry has limitations, it does permit an estimate of hearing status in nearly all children regardless of their age or developmental level.

Aphasia

The composite Corethane/Dacron vascular prosthesis. Canine in vivo evaluation of 4 mm diameter grafts with 1 year follow-up.

Polyurethane vascular prostheses offer the potential of superior thromboresistance and reduced anastomotic hyperplasia compared to existing Dacron and ePTFE alternatives, but have suffered from susceptibility to biodegradation, with resulting mechanical failure. To address this problem, the authors have developed and evaluated a composite prosthesis comprised of: 1) an inner blood interfacing elastomeric porous membrane made from Corethane, a proprietary Shore 80A polyurethane like material substantially devoid of ether/ester linkages, with superior biostability over conventional polyether urethanes, spun into a nonwoven structure with fiber diameters 10-15 microns and pore sizes 30-60 microns filled with gelatin +/- heparin; and 2) an outer soft, tissue interfacing, warp knitted Dacron mesh bonded to the inner layer to assure long-term dimensional stability. Twenty 4 mm ID x 5 cm L composite prostheses, half with heparinized gelatin (the remainder nonheparinized) were implanted as femoral interposition grafts in 10 dogs. Four of the 10 nonheparinized grafts occluded. All 10 with heparin remained widely patent, with two explanted at 6 months showing vascularized connective tissue growth through the graft, in contrast to the giant cell inflammatory response to the Dacron mesh, with a substantially endothelialized neointima and no Corethane biodegradation. Of the 10 patent grafts at 1 year follow-up, none showed aneurysm formation. This vascular prosthesis provides compliance superior to ePTFE and Dacron alternatives, with excellent suture retention and good kink resistance, while combining the superior thromboresistance and tissue ingrowth properties of polyurethanes with the proven biostability of Dacron.

Animals

Effects of increased stimulus rate on brainstem electric response (BER) audiometry as a function of age.

The purpose of this investigation was to describe the effects of rate of stimulus presentation on the brainstem electric response in groups selected as models for such brainstem disorders as demyelinating diseases and focal lesions. Two groups, infants and geriatric adults, were chosen as models because of their known neurological differences from a normal young adult population. Three groups of eight subjects each; infants, geriatric adults, and young adults were tested using routine brainstem electric response techniques with four rates of click presentations. Using the wave V latency at the slow rate (13/sec) as base line, three latency shift scores were obtained for each of the three fast rates (33/sec), 50/sec, 67/sec). Analysis of the data revealed greater shifts for infants and geriatric adults than were present for the young adults. The experimenters concluded that the imposition of a fast rate of click presentation offers a promise as a clinical tool for the discovery of brainstem differences.

Adolescent

Brainstem wave V latencies to tone pip stimuli.

The present study was undertaken to examine the feasibility of using tone pip stimuli rather than conventional clicks in brainstem evoked response (BER) audiometry. Trains of 2000-Hz tone pips, 4000-HZ tone pips or clicks were presented at seven intensity levels to six normal young adults. Results demonstrated that BERs can be readily elicited by tone pips. This latter finding may be attributable to the differences in stimulus rise times. Tone pips appear to introduce greater frequency specificity to BER audiometry without a marked loss in the ability to elicit the response.

Acoustic Stimulation

Brainstem evoked response (BER) audiometry at various stimulus presentation rates.

The utilization of the latency of the brainstem auditory evoked response to estimate the status of high frequency hearing is rapidly becoming a part of the audiologist's clinical armamentarium. Because it is important to utilize the most efficient rate of stimulus presentation, the present investigation was undertaken to provide some initial latency information for three commonly used stimulus rates. Brainstem auditory evoked responses were recorded from 22 adults for three click rates (13.3/sec, 33.3/sec, and 67/sec) at seven intensity levels (10 to 60 dB sensation level). It was shown that rate of click presentation markedly affects the intensity-latency functions for wave V. In clinical use, norms must be established for each stimulus rate used to maximize the accuracy of the test results.

Acoustic Stimulation