Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method.

UNLABELLED: Calibration, i.e. the transformation in real time of the signal I(t) generated by the glucose sensor at time t into an estimation of glucose concentration G(t), represents a key issue for the development of a continuous glucose monitoring system. OBJECTIVE: To compare two calibration procedures. In the one-point calibration, which assumes that I(o) is negligible, S is simply determined as the ratio I/G, and G(t) = I(t)/S. The two-point calibration consists in the determination of a sensor sensitivity S and of a background current I(o) by plotting two values of the sensor signal versus the concomitant blood glucose concentrations. The subsequent estimation of G(t) is given by G(t) = (I(t)-I(o))/S. RESEARCH DESIGN AND METHODS: A glucose sensor was implanted in the abdominal subcutaneous tissue of nine type 1 diabetic patients during 3 (n = 2) and 7 days (n = 7). The one-point calibration was performed a posteriori either once per day before breakfast, or twice per day before breakfast and dinner, or three times per day before each meal. The two-point calibration was performed each morning during breakfast. RESULTS: The percentages of points present in zones A and B of the Clarke Error Grid were significantly higher when the system was calibrated using the one-point calibration. Use of two one-point calibrations per day before meals was virtually as accurate as three one-point calibrations. CONCLUSION: This study demonstrates the feasibility of a simple method for calibrating a continuous glucose monitoring system.

Biosensing Techniques↗

Calibration of a subcutaneous amperometric glucose sensor. Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current.

The calibration of a continuous glucose monitoring system, i.e. the transformation of the signal I(t) generated by the glucose sensor at time (t) into an estimation of glucose concentration G(t), represents a key issue. The two-point calibration procedure consists of the determination of a sensor sensitivity S and of a background current I(o) by plotting two values of the sensor signal versus the concomitant blood glucose concentrations. The estimation of G(t) is subsequently given by G(t) = (I(t)-I(o))/S. A glucose sensor was implanted in the subcutaneous tissue of nine type 1 diabetic patients during 3 (n = 2) and 7 days (n = 7). For each individual trial, S and I(o) were determined by taking into account the values of two sets of sensor output and blood glucose concentration distant by at least 1 h, the procedure being repeated for each consecutive set of values. S and I(o) were found to be negatively correlated, the value of I(o) being sometimes negative. Theoretical analysis demonstrates that this phenomenon can be explained by the effect of measurement uncertainties on the determination of capillary glucose concentration and of sensor output.

Biosensing Techniques↗

Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring.

The changes in plasma glucose concentration and in interstitial glucose concentration, determined with a miniaturized subcutaneous glucose sensor, were investigated in anesthetized nondiabetic rats. Interstitial glucose was estimated through two different calibration procedures. First, after a glucose load, the magnitude of the increase in interstitial glucose, estimated through a one-point calibration procedure, was 70% of that in plasma glucose. We propose that this is due to the effect of endogenous insulin on peripheral glucose uptake. Second, during the spontaneous secondary decrease in plasma glucose after the glucose load, interstitial glucose decreased faster than plasma glucose, which may also be due to the effect of insulin on peripheral glucose uptake. Third, during insulin-induced hypoglycemia, the decrease in interstitial glucose was less marked than that of plasma glucose, suggesting that hypoglycemia suppressed transfer of glucose into the interstitial tissue; subsequently, interstitial glucose remained lower than plasma glucose during its return to basal value, suggesting that the stimulatory effect of insulin on peripheral glucose uptake was protracted. If these observations obtained in rats are relevant to human physiology, such discrepancies between plasma and interstitial glucose concentration may have major implications for the use of a subcutaneous glucose sensor in continuous blood glucose monitoring in diabetic patients.

Animals↗

Continuous glucose monitoring in the free-moving rat.

The aim of this work was to set up an experimental model of glycemic fluctuations for assessing in the conscious freely moving rat, the performance of a continuous glucose-monitoring system, using a pocket-calculator-size electronic control unit and a miniaturized subcutaneous glucose sensor. The well-known triphasic glycemic pattern following streptozotocin injection (initial peak and secondary hypoglycemia preceding the establishment of permanent hyperglycemia) was used as a way to obtain spontaneous changes in blood glucose level over a wide concentration range. This report demonstrates that streptozotocin injection produced highly reproducible changes in the current generated by the sensor: an initial peak and a secondary nadir, during which blood sampling provided the evidence of hyperglycemia associated with immunoreactive hypoinsulinemia, and of hypoglycemia associated with hyperinsulinemia, respectively. This reproducible experimental model should be valuable for the assessment of a continuous glucose-monitoring system.

Animals↗

A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm.

A crucial step in developing a glucose monitoring system using a subcutaneous implanted glucose sensor is the transformation of the sensor signal (a current) into an estimation of a blood glucose concentration. We have developed an Electronic Control Unit (ECU) able to recognize, before and after a glucose load, that the sensor current presents a plateau, thus triggering an alarm asking for blood glucose determination. The system, fed with these results, subsequently transforms the current into an estimation of glucose concentration by linear extrapolation based on the sensor sensitivity and the background current computed from the two sets of current and glycaemia values (two-point calibration). In addition, the system is able to trigger an alarm when this estimation decreases below a threshold that can be set by the user. This system was evaluated in experiments performed in 12 normal rats. The quality of the calibration was assessed by comparing, by error grid analysis, the data displayed on the liquid-crystal display of the ECU to concomitant plasma glucose concentration determined at frequent intervals, 65 +/- 6 and 26 +/- 5% of the values were in zones A (good) and B (acceptable estimation) of the grid, respectively. The system was set to trigger an alarm when the estimation of glucose concentration decreased below 70 mg/dl. Following an insulin administration, the alarm was triggered when the system displayed a 64 +/- 2 mg/dl glucose concentration. The concomitant plasma glucose concentration was 59 +/- 5 mg/dl (NS). In conclusion, this work validates experimentally the new, user-friendly method for calibrating the glucose sensor integrated into the ECU, based on an automatic detection of plateaus. The quality of the sensor calibration performed with this procedure is compatible with the appropriate functioning of this continuous glucose monitoring system, which was demonstrated by its ability to detect mild hypoglycaemia following insulin injection.

Animals↗