Computer-assisted total knee arthroplasty using patient-specific templating.

Current techniques used for total knee arthroplasty rely on conventional instrumentation that violates the intramedullary canals. Accuracy of the instrumentation is questionable, and assembly and disposal of the numerous pieces is time consuming. Navigation techniques are more accurate, but their broad application is limited by cost and complexity. We aimed to prove a new concept of computer-assisted preoperative planning to provide patient-specific templates that can replace conventional instruments. Computed tomography-based planning was used to design two virtual templates. Using rapid prototyping technology, virtual templates were transferred into physical templates (cutting blocks) with surfaces that matched the distal femur and proximal tibia. We performed 45 total knee arthroplasties on 16 cadaveric and 29 plastic knees, including a comparative trial against conventional instrumentations. All operations were performed using patient-specific templates with no conventional instrumentations, intramedullary perforation, tracking, or registration. The mean time for bone cutting was 9 minutes with a surgical assistant and 11 minutes without an assistant. Computer-assisted analyses of six random computed tomography scans showed mean errors for alignment and bone resection within 1.7 degrees and 0.8 mm (maximum, 2.3 degrees and 1.2 mm, respectively). Patient-specific templates are a practical alternative to conventional instrumentations, but additional clinical validation is required before clinical use.

Aged↗

Conditioning of cartilage during normal activities is an important factor in the development of osteoarthritis.

Mechanical factors have long been implicated in the aetiology of osteoarthritis (OA). The two most popular hypotheses regarding the mechanism of cartilage damage are: the application of too high a stress and the mechanism of fatigue. Mechanical failure in any material, however, can be caused by either or both of these mechanisms. It is hypothesized that, because cartilage is a living tissue, the threshold at which it fails by either mechanism is regulated by the prevalent stresses arising in a joint. As these stresses are determined by activities and lifestyles, a low failure threshold can be the result of prolonged periods of low-level activity, which, if interrupted with short periods of intense activities, can subject weakened cartilage to damaging stresses. Were this hypothesis proven, it would address difficulties encountered with these hypotheses and explain some clinical observations. It would also have implications for the activities and lifestyles of individuals.

Adult↗

Personalised image-based templates for intra-operative guidance.

The high rate of unplanned perforation, poor fixation, and nerve injury with freehand pedicle screw insertion has led to the use of image-guided navigation systems. Although these improve accuracy, they have several drawbacks that could be overcome by using image-based drilling guide templates. The accuracy of such templates was tested in a cadaveric study of screw placement in the lumbar, thoracic, and cervical regions of the spine. The dimensional stability with autoclaving of duraform polyamide, to be used for manufacturing the guides, was first determined using test specimens. Computed tomography (CT) images were acquired of 4 cadaveric spines, and placement of 4 cervical, 32 thoracic, and 14 lumbar screws was planned. Eighteen personalized drilling guide templates, in four different designs, were built. Orthopaedic surgeons experienced in the freehand techniques used the templates. CT images were acquired to assess placement position with respect to the pedicle. Duraform polyamide was found to be unaffected by sterilization. Two of the template designs facilitated the placement of 20/20 screws without error. Templates can lead to successful screw placement, even in small pedicles, providing their design is optimized for the application area, e.g. with enhanced rotational stabilization.

Bone Screws↗

Zonal and directional variations in tensile properties of bovine articular cartilage with special reference to strain rate variation.

UNLABELLED: THE AIMS of this study were: (i) to investigate the variation in the tensile properties of articular cartilage with depth through cartilage thickness and fibre orientation; (ii) to determine the effect of strain rate on tensile properties of articular cartilage. MATERIALS AND METHOD: All experimental work was performed on cartilage specimens taken from two bovine knee joints. Osteochondral plugs 12 mm in diameter were harvested with a special reamer from the femur and the tibial plateaux of each knee. Slices (0.2 mm thick), of articular cartilage were cut from the plug with a microtome. The predominant orientation of the collagen fibres on the cartilage surface was determined using the pinpricking technique. Each specimen used for the tensile test was cut, so as to produce a dumbbell shape, with a gauge length of 6 mm. Uniaxial tensile tests were performed on each specimen in order to determine the tensile Young's modulus, and ultimate tensile strength (UTS). In this investigation, these tensile tests were carried out at different strain rate: 1, 20, 50 and 70%/sec. RESULTS: As regards the zonal properties, it was found that tensile stiffness was greater in the superficial layer than in deep layer. However, a few specimens from the deep layer displayed similar or greater stiffness compared to the superficial layer. With respect to the directional properties, the specimens oriented parallel to the predominant alignment of collagen, were stiffer than those, which were perpendicular to it in each layer. However, only the results regarding the deep layer can be considered statistically significant. In regard to the variation of modulus with the strain-rate, the results showed that there is no significant increase of the modulus with increasing strain rate from 20 to 50% per second. However, at 70% per second, articular cartilage stiffness considerably increased by up to one order of magnitude greater than that determined at lower strain rates in both the superficial and deep layer. Moreover, the UTS of cartilage specimens tested at 70% per second showed a significant rise, reaching values of four to five times that of those measured at 1, 20 or 50% per second. CONCLUSION: The steep increases in both the stiffness and ultimate tensile strength of cartilage at high strain rates point to the existence in cartilage of a mechanism for its protection from damage by stresses arising in trauma, which are usually applied at high rates. This mechanism needs to be elucidated. The reduced anisotropy found in the present study pointed out that collagen is likely to be less organized in bovine cartilage than in the human and therefore, a study of its ultra-structure would be appropriate.

Adaptation, Physiological↗

The longitudinal Young's modulus of cortical bone in the midshaft of human femur and its correlation with CT scanning data.

This study was concerned with establishing the regional variations in the magnitude of the longitudinal Young's modulus of the cortical bone in the femoral midshaft and with investigating whether a relationship existed between the Young's modulus of bone and the CT number. Were such a relationship to exist this would provide a noninvasive method of assessing the quality of bone in the regions of fixation of implants to bone. The data would be of considerable aid to designers of implant stems to withstand the stresses arising at its interface with the bone. Five pairs of fresh frozen human femora were used. Several beam-shaped small specimens were methodically harvested from each pair and were used to measure the longitudinal modulus adopting the three-point bending test, which was carried out with a specially constructed and validated apparatus. CT scans of the bone were obtained, prior to harvesting the specimens, and the CT number was measured at locations corresponding with the specimen sites. The results indicate that in the femoral midshaft the cortical bone has an average Young's modulus value of 18600 +/- 1900 MPa. This agrees well with data obtained by other researchers using different experimental methods. Statistical analyses revealed no regional variations in the value of the longitudinal modulus of the bone. No correlation was found between the bone modulus and the CT number. Thus a noninvasive method for establishing the bone properties still remains a challenge.

Aged↗

Quality assessment of the cortical bone of the human mandible.

This study is the first to investigate simultaneously both the regional and the directional variations in mechanical properties and computed tomography (CT) numbers of the fresh mandible bone and to explore the correlation between the two sets of data with a view to provide a noninvasive method for determining the bone quality for designers of dental implants. Using a three-point bending test the regional variation of Young's modulus of bone in the human mandible was determined from five fresh specimens from donors representative of patients in need of dental implants in that some of the mandibles were fully dentulate, some partly so, and some fully edentulate. While a pattern of the modulus distribution was evident in the mandibles we tested, these mandibles did have, as a result of their respective states, their own peculiarities. We determined also the directional variations of the modulus for the mandible, which are due to the anisotropic nature of bone. The modulus values obtained in our study were much lower than those listed in the only other published study, which was conducted on dry mandibles. These differences in the modulus data from the two studies were attributed partly to the differences in condition of the bone and differences in the dimensions of specimens tested in the two studies. Because the values of the modulus obtained in this study are lower than those previously published, they would be safer as a basis for implant designs. A weak correlation was found between the modulus values and the CT number of the mandible. This would not be sufficient for accurate predictions of the bone properties from CT scans. The development of a noninvasive method for determining the bone quality in various patients thus remains a challenge for researchers.

Aged↗

Effect of implant lengthening and mode of fixation on knee laxity after ACL reconstruction with an artificial ligament: a cadaveric study.

An "apparent" lengthening of the ligament implant, which causes an increase in knee laxity after the reconstruction of the anterior cruciate ligament (ACL) may be due to either slippage of the implant from under the fixation devices, or tunnel migration (due to bone resorption). These two mechanisms are related to the initial ligament placement, implant tensioning, and fixation modes. This cadaveric study simulates, in a controlled experimental situation, the postoperative lengthening of artificial ACL implants, and seeks to quantify the consequent increase in joint laxity. Eight cadaveric right knees, in which the Leeds-Keio artificial ligament was implanted, were tested in a specially constructed apparatus, which allowed the knee joint six degrees of freedom. In each of the tested joints the laxity was measured under several test conditions for two final fixation modes of the implant. The difference between the fixation modes was the application (as in mode B) or not (as in mode A), of a posteriorly directed force of 50 N on the tibia, at the moment of final fixation of the ligament. In both cases a tensile load of 50 N was maintained along the implant. All measurements were taken at flexion angles of 20 degrees and 90 degrees and with controlled implant lengthening of up to 3 mm in 0.5-mm increments. After implantation, adopting fixation mode B resulted in the knee exhibiting an anterior laxity considerably less than the original physiological laxity, compared with that measured after using fixation mode A. Thus at 20 degrees of knee flexion, under an anterior load of 100 N applied on the tibia, adopting fixation mode B, the joint laxity was 2.8 mm smaller than the natural laxity, whereas, for fixation mode A, it was 1.4 mm larger. At 90 degrees of knee flexion, the situation was similar, but with smaller differences. However, the situation was overturned as the implant length was increased. Thus, at 20 degrees of knee flexion, when the implant was lengthened in a range of 1--2 mm, the laxity observed with fixation mode B was similar to that recorded when the ACL was intact, whereas the laxity observed with fixation mode A was about 3--4 mm greater. Similar data were observed at 90 degrees of knee flexion. It appears that fixing the implant finally by applying a tensile load on it while simultaneously pushing the tibia posteriorly could be an effective measure against the possible return of joint laxity.

Adult↗

Roles of the anterior cruciate ligament and the medial collateral ligament in preventing valgus instability.

Both the medial collateral ligament (MCL) and the anterior cruciate ligament (ACL) are reported to prevent valgus instability of the knee. In this study, the anatomical mechanisms by which these ligaments prevent valgus instability were experimentally investigated. The valgus rotation angle and the magnitude of the medial joint space opening were measured in six cadaveric knees, using biplanar photography before and after the MCL and/or the ACL were severed. A significant increase in the valgus rotation angle and a large medial joint space opening were observed when the MCL was severed. An increase in the valgus rotation angle was also observed when the ACL was severed, but only a small medial joint space opening was present. The increase in the valgus rotation angle after ACL severance was nearly parallel to the increase in the internal rotation of the tibia. Thus, we concluded that both ligaments function to prevent valgus instability, but that the anatomical reasons for their function are different. The MCL prevents valgus instability by stopping an opening in the medial joint space. The ACL, on the other hand, prevents the internal rotation of the tibia. When the ACL is severed, the internal rotation increases, and causes the valgus rotation angle to also increase, despite the presence of only a small medial joint space opening.

Adult↗

Mechanical behaviour of articular cartilage under tensile cyclic load.

INTRODUCTION: Although fatigue has been implicated in cartilage failure, there are only two published studies in this area, by the same author. However, in these previous studies cartilage was tested in the direction parallel to that of collagen orientation in the superficial layer, where it possesses greater tensile strength. In the present work, articular cartilage was also tested along the direction perpendicular to that of the collagen. Furthermore, the study investigated topographic and zonal variations in the fatigue behaviour of cartilage from the human knee. METHODS: Specimens were tested in a specially constructed apparatus that allowed the number of cycles at specimen failure, as well as the load and elongation of the specimen, to be monitored for each specimen. To date, some 72 specimens have been tested, all from the same knee joint, though from different sites and at different depths within the cartilage layer. RESULTS AND CONCLUSIONS: The most impressive of the outcomes of this study is the scatter of the data. Considering all the specimens used, the range of number of load cycles to failure was between 2 and 1.5 million. The zonal variation in fatigue behaviour was similar to that in tensile modulus reported previously; the surface and deep layers seemed to have better fatigue properties whether tested in the direction parallel or perpendicular to that of the collagen in the superficial layer. The middle layer was far weaker, suggesting that highly packed and ordered fibres in the surface and deep zones have better mechanical properties than the more random and loose fibres in the middle zone. The variation in fibre organization through the cartilage thickness was also reflected in the differences observed in the elongation of the specimen during the test. The surface and deep zones had a higher stiffness than the middle zone. Cartilage had better fatigue resistance when the specimen was loaded in a direction parallel rather than perpendicular to the collagen within the surface layer. This was true whether specimens were harvested from the superficial, intermediate or deep layer. There were many factors that confounded attempts to estimate the likely fatigue life from the data obtained in such a study.

Cartilage, Articular↗

The relationship of the compressive modulus of articular cartilage with its deformation response to cyclic loading: does cartilage optimize its modulus so as to minimize the strains arising in it due to the prevalent loading regime?

AIM: To investigate the relationship of the instantaneous compressive modulus with its deformation response to cyclic loading typical of that encountered at the knee joint during level walking. METHOD: The study was performed on 24 osteochondral plugs taken from three unembalmed cadaveric knees. As the compressive modulus of cartilage has been shown to vary topographically across the knee in an established manner, the specimens were taken from specific sites on the femur and tibia of each knee. All the cartilage specimens were immersed in Hanks' salt solution at 37 degrees C and were subjected to the same cyclic loading regimen that was representative of a typical walking cycle in a specialized indentation apparatus, for over 1 h. RESULTS AND CONCLUSION: The viscous and elastic components of matrix strain, the creep rate and the cartilage compressive modulus were measured. The latter was found to be significantly related to the strain response of cartilage to cyclic loading. Elastic strain varied exponentially with the compressive modulus; specimens with a modulus less than 4 MPa experienced elastic strains in the range 0.18-0.36, whereas stiffer specimens experienced strains between 0.05 and 0.13. Viscous strain varied linearly with cartilage stiffness and was as low as 0.02 at the lower values of the compressive modulus but increased to 0.22 for a compressive modulus of 18 MN/m(2). The rate of creep under cyclic load was inversely linearly related to cartilage stiffness. The strain response of soft specimens approached steady state by 200 cycles but that of stiff specimens did not approach it until 1300 cycles. It was hypothesized that the viscous strain response of cartilage can be explained in terms of differences in permeability between specimens of different compressive modulus, stiffer cartilage having a lower permeability than soft cartilage.

Cadaver↗

Modelling femoral curvature in the sagittal plane: a cadaveric study.

This study examined the possibility of representing the mid third of the human femur with two straight sections. This portion of the femur visually has a distinct curvature, which can potentially present problems when considering implant stem designs to be introduced in this region. Sixteen femora were sectioned at 10 mm intervals along the femoral shaft in the mid third region (35-65 per cent of femoral length). Photographic records were obtained of each section against a consistent axis system to which all coordinates were referenced. The position of the centre of the medullary canal cross-sectional area along the femur, in relation to fixed orthogonal planes, has been analysed; the outer anterior cortex was also modelled. The results showed that the medullary centre of area plots and the anterior cortex coordinates are suitably modelled as two straight lines. For each bone it was possible to define the intersection point between the two straight sections (point of angulation), and the subtended angle between these sections (angle of incidence). The average point of angulation for the medullary plots occurred at 57 per cent along the femur, while the mean angle of incidence was 6.5 degrees. The anterior surface had an average point of angulation at 58 per cent along the femur with the mean angle of incidence being 22.2 degrees. The centre-line of the medulla was also found to be almost parallel to the outer anterior surface for sections distal to the point of angulation. It is proposed therefore, that this difference in angulation is the result of medullary expansion/cortical thinning towards the proximal extremity of the femur, causing the straight-line model of the medulla to angulate less than the outer anterior cortex.

Cadaver↗

Axis location of tibial rotation and its change with flexion angle.

The magnitude and location of the axis of tibial rotation were measured at 15 degrees increments between 0 degree and 90 degrees flexion using 24 normal anatomic knee specimens, and their changes with flexion angle were investigated. The magnitude of tibial rotation was small (8.3 degrees) at 0 degree flexion, but increased rapidly as the flexion angle increased and reached a maximum rotation (31.7 degrees) at 30 degrees flexion. It then decreased again with additional flexion (24.8 degrees at 90 degrees flexion). The location of the axis was close to the tibial insertion of the anterior cruciate ligament at 0 degree flexion, gradually moving toward insertion of the posterior cruciate ligament (observed at 45 degrees and 60 degrees flexion), and then moved anteriorly again with additional flexion: the axis was approximately equidistant from the two cruciate insertions at 90 degrees flexion. The results showed that a relatively large degree of tibial rotation was possible in a normal knee and that the location of the axis remained approximately in the area between the two cruciate ligament insertions throughout the range of flexion. However, the location of the axis changed with the flexion angle within this area according to the changes in direction and tension of the cruciate ligaments and the surrounding soft tissues.

Adult↗

Anterior cruciate ligament reconstruction with the Leeds-Keio artificial ligament.

The Leeds-Keio (L-K) artificial ligament, developed for knee ligament reconstruction, is made of polyester with a maximum tensile strength of 2200 N. This implant works not only as a ligament but also as a scaffold onto which natural tissue grows from synovium. In an animal experiment, each strand of the L-K ligament was covered with new tissue by 2-3 weeks after anterior cruciate ligament reconstruction. Eight weeks postoperatively, abundant fibrous tissue with extensive vascularity covered the implant, which was still histologically immature. After 16 weeks, vascularization and tissue induction began to subside, and histologic analysis showed dense fibers running longitudinally and parallel. By 36 weeks, the new ligament looked like a natural anterior cruciate ligament, although histologically more cells could be seen than in the natural ligament. This maturation was observed only when the substitute was implanted under good tension. Clinically, the surgical procedure has been improved over the past 10 years, to the current practice in which the tape-in-tube double L-K ligament employs a small piece of autogenous tissue to promote early tissue induction and maturation. Using this practice (n = 135), more than 85% of the patients were satisfied subjectively, objectively, and arthroscopically at the 5-year postoperative FU period. Few patients had joint effusion postoperatively. Sacrifice of autogenous tissue is minimal. The patient can return to activities of daily living within 2 weeks, and more than 50% of them to sports within 10 weeks, and the new ligament is expected to keep its function for a long period as ingrowth completes the structure biologically.

Activities of Daily Living↗

Reconstructive treatment of posterolateral rotatory instability of the knee: a biomechanical study.

Twelve cadaveric knees were tested to determine effective reconstructive treatment for severe chronic posterolateral rotatory knee instability accompanied by excessive varus and posterior laxity. Posterolateral, varus, and posterior laxity were measured, first with the ligaments intact, then after complete sectioning of the posterior cruciate ligament (PCL) and posterolateral structures, and finally after reconstruction of these structures in different orders. The increases in those laxities were produced following the sectioning of all of the structures and disappeared throughout the flexion range after combined reconstruction of the PCL, lateral collateral ligament (LCL), and popliteus tendon. However, some residual increase in the laxity was always observed if any of the three structures were excluded from reconstruction. Therefore, combined reconstruction of the PCL, LCL, and popliteus tendon is essential and adequate for treating severe chronic posterolateral rotatory instability.

Biomechanical Phenomena↗

'Equivalent geometry' of the knee and the prediction of tensions along the cruciates: an experimental study.

In this paper we introduce the concept of the functional (or equivalent) geometry of the knee, which is an attempt to reduce the natural knee with its complex geometry, frictional resistance and deformable cartilage into a two-dimensional joint comprising rigid femur and tibia in frictionless contact. An apparatus and method are described to measure the slope of the tangent to the surfaces of the 'equivalent' bones at their 'point' of contact. An antero posterior force of +/-300-500 N and axial compressive load of twice body weight were applied on cadaveric knee joints. The corresponding displacement of the tibia in the saggital plane was measured firstly with both cruciates intact and then when each was severed in turn. From the data obtained both the slope of the tangent mentioned above and the tensions developed along the cruciates under the influence of the forces applied were calculated. The results showed that the functional geometry of the knee in the saggital plane can be represented by a convex femur and a concave tibia. The tensions along the cruciates calculated on the basis of the experimental measurements were nearly always lower than the antero posterior force applied, and although this corroborated the trend demonstrated in a previous theoretical analysis, they were lower still. The reason for this may be the deformation of the cartilage under load, thus modifying the geometry of contact resulting in a more concave tibia of the 'equivalent' knee joint, than that of the rigid model used in the theoretical analysis.

Anterior Cruciate Ligament↗

A new concept for a metacarpophalangeal prosthesis: consequence on joint biomechanics.

OBJECTIVE: The purpose of this work was to establish whether surface replacement non-constrained prostheses can duplicate the normal biomechanics of the metacarpophalangeal joint. DESIGN: A series of mathematical models. BACKGROUND: A non-constrained prostheses has been designed for the replacement of the metacarpophalangeal joint. It uses the concept of surface replacement in that it attempts to replicate the anatomy of the original cartilage surfaces. The centre of rotation of the prosthesis is also sited at the same position as in the natural joint to maintain the balance between the flexor and extensor tendon forces, such that the prosthesis duplicates the biomechanics of the normal joint. Due to the unique dimensions of each joint that may present for surgery, the four sizes of prosthesis that are available for implantation may not always produce an exact replication of the joint kinematics. These situations were examined to establish whether the biomechanics of the joint can indeed be restored. METHODS: Mathematical models for each size of prosthesis implanted into a range of different sized metacarpophalangeal joints were developed. The prosthetic and cartilage surface profiles were compared and the balance between the tendon forces was examined. RESULTS: Differences in size that may occur between the surface profiles of the normal joint and prosthesis, together with any relocation of the centre of rotation, would have negligible effects on the normal joint biomechanics. CONCLUSIONS: All four sizes of the non-constrained prosthesis can duplicate the normal biomechanics of the joint and hence provide normal function.

Biomechanical Phenomena↗

Ultrasonic measurement of the thickness of human articular cartilage in situ.

OBJECTIVE: The objective of the present study was to explore the possibility of using the ultrasonic pulse-echo technique for the non-invasive measurement of cartilage thickness in situ during a joint arthroscopic examination. The accuracy of the ultrasonic measurement was assessed in vitro against that of an established needling technique which is destructive. METHODS: The velocity of sound in articular cartilage was measured in an in vitro study of one set of ipsilateral human ankle and hip joints at 69 test sites. Its variability was determined. RESULTS: The velocity of sound in human articular cartilage measured in situ varied widely (1419-2428 m/s; mean: 1892 m/s; S.D. 183 m/s) and therefore the error in the thickness of cartilage obtained from ultrasonic measurement based upon a constant velocity of sound could be as large as 33.6% (mean 7. 38%; S.D. 6.25%). CONCLUSIONS: The ultrasonic pulse-echo technique is not accurate for the measurement of the thickness of cartilage in situ. An alternative (albeit minimally invasive) would be the needling technique. This requires the development of a specialized probe.

Aged↗

The 'instantaneous' compressive modulus of human articular cartilage in joints of the lower limb.

METHODS: The instantaneous compressive modulus of articular cartilage was surveyed in 11 sets of human lower limb joints obtained from the ipsilateral side. The average modulus for the entire joint surface of each joint and the topographical variations in the modulus within each joint were examined for all 11 sets, and subjected to statistical analysis. RESULTS: Within each set of joints (hip, knee and ankle), the ankle always had a significantly greater mean compressive modulus than the hip and knee (P < 0.001-P < 0.05). In seven sets of joints, there was no significant difference between the mean compressive moduli of the knee and hip joints. In three sets of joints, the compressive modulus of the knee was significantly greater than that of the hip (P < 0.001-P < 0.01), while in only one set of joints was the compressive modulus of the hip significantly greater than that of the knee (P < 0.01). CONCLUSION: The topographical variations in the cartilage instantaneous compressive modulus over the surfaces of the lower limb joints were matched by differences in the stresses occurring in different areas of each joint. The results of the present study corroborate previous findings and show that the site-specific stresses and corresponding values of the instantaneous cartilage compressive modulus over the surfaces of lower limb joints were correlated (r = 0.82 at P < 0.01), thus adding credence to the conditioning hypothesis of cartilage by prevalent stress.

Adult↗