PubMed Health⌕ Search

Biomedical subjects

B Blümich

Publications and source records attributed to B Blümich.

60 records · Page 4Linked to original sources

Segmental anisotropy in strained elastomers detected with a portable NMR scanner.

Single-side NMR is particularly suitable for measurements of segmental anisotropy induced in elastomers by uniaxial forces or local strain. Proton transverse nuclear magnetic relaxation was investigated with the NMR-MOUSE by recording the Hahn-echo decay in cross-linked natural rubber bands. This provided information on the dependence of the Hahn-echo decay on the angle between the direction of the uniaxial stretching force and the axis Z defined direction perpendicular to the magnet pole faces of the NMR-scanner. The anisotropy effect on the Hahn-echo decay is correlated with the extension ratio, and it is more evident in the liquid-like regime of the decay. A weaker segmental anisotropy is detected by 1H solid- and Hahn-echo decays recorded by multi-pulse sequences. A qualitative understanding of the angular dependence is obtained by an analytical theory of the Hahn-echo decay adapted to the case of stretched elastomers and to strongly inhomogeneous magnetic fields. Using angular-dependent 1H residual second van Vleck moments and correlation times reported previously [P.T. Callaghan and E.T. Samulski, Macromolecules 30, 113 (1997)] from stretched natural rubber bands the segmental anisotropy measured in inhomogeneous magnetic fields by the Hahn-echo decay was numerically simulated. As an example of a macroscopic distribution of local segmental anisotropy, 1H Hahn-echo decays were measured by the NMR-MOUSE sensor in a stretched cross-linked natural rubber plate with a circular cut in the center.

Anisotropy↗

Multi-gradient pulse investigations of fluid transport in porous media.

NMR pulsed field gradient (PFG) experiments employing the application of n gradient pulses k(1) ellipsis k(n) are discussed in a general way as an n-fold encoding of position at successive times. The experiments are then represented by a sampling of n-dimensional k-space, K(n). Various parameters of motion can be derived from the evolution of correlations within the n-dimensional position (r-)space, R(n), which is the Fourier conjugate space to K(n). A wide class of NMR experiments may be described by this formalism, where the dimension of the experiment is often reduced by imposing conditions to the free variables. This is demonstrated for the case of displacement measurements where the condition summation operatork(i) = 0 is met. The two simplest pulse sequences which allow one to correlate displacements at two different times with each other are presented. While the three-pulse version of SERPENT encodes displacements in two interleaved time intervals Delta(1) and Delta(2), the four-pulse VEXSY experiment includes a mixing time tau(m) in between both encoding intervals Delta. The behaviour of fluid transport subject to external pressure through a model porous system is demonstrated by means of numerical simulations of SERPENT and VEXSY experiments for water flowing through a packed bed of monosized spherical particles. Displacements parallel (Z) and perpendicular (X) to the main flow direction are determined and the 2-D joint probability densities and the conditional probabilities are discussed along with the correlation coefficients related to the displacements at different encoding times. It is shown that all possible correlations between Z and X(2) in VEXSY decay with time constants comparable to the average time needed for a fluid molecule to cover one bead diameter, while a negative correlation is observed between transverse (X) displacements which is explained by molecules flowing along streamlines which follow the circumference of the spherical particles. Correlations for displacements during the different times in SERPENT generally decay much slower and provide complementary information about the evolution of displacements with time.

Computer Simulation↗

The NMR-MOUSE: quality control of elastomers.

New applications of the NMR-MOUSE (mobile universal surface explorer) to non-destructive quality control of elastomers are reported. One example concern the thermal aging of fast clutches which was probed by measurements of 1H transverse relaxation time. Novel methodological developments show that 1H double-quantum filtered NMR signals can be generated in the inhomogeneous fields of the NMR-MOUSE for characterization of residual dipolar couplings. This technique was applied to characterize reference natural rubber samples with different crosslink density and carbon black and silica fillers.

Elastomers↗

Analysis of historical porous building materials by the NMR-MOUSE.

Samples of sandstone with and without deposits of silicon oxide stone strengthener as well as samples of historical brick material were analyzed by transverse NMR relaxation and mercury intrusion porosimetry. Relaxation times and relaxation time distributions of the protons from the water saturated samples were measured by low-field NMR using homogeneous and inhomogeneous fields. The measurements in inhomogeneous fields were performed with two different NMR-MOUSE sensors, one with a field gradient of 2 T/m and the other with an average field gradient of about 20 T/m. In the sandstone samples the application of stone strengtheners was shown to result in a confinement of the large pores within the outer layer of a few millimeters depth. Depending on the ferromagnetic contamination of the brick samples, the relaxation time distributions can be affected. The agreement of T2 relaxation time distributions and pore size distributions from mercury intrusion porosimetry was found to be better for the NMR-MOUSE sensors than for the homogeneous field measurements. This is true even for different brick samples, unless the content in ferromagnetic particles is very strong.

Archaeology↗

The NMR-mouse: construction, excitation, and applications.

A mobile nuclear magnetic resonance (NMR) device similar to a bore-hole probe has been developed for applications in materials science and biomedicine. Inhomogeneous polarizing and radio-frequency (rf) magnetic fields are applied to arbitrarily large samples from one side. Different experimental techniques have been tested to measure transverse and longitudinal relaxation times and translational diffusion constants. Good contrast for discrimination of material properties is gained when the residual dipolar coupling is retained in soft matter by avoiding spinlock effects in multi-pulse techniques. Applications to characterization of products from technical elastomers, skin, and coatings on iron sheets are reported.

Animals↗

[Portable NMR-MOUSE: a new method and its evaluation of the Achilles tendon].

AIM: The increased demands placed on the Achilles tendon in recreational and professional sports have led to a rise in pathological changes in this anatomic region. Magnetic resonance evaluations of the tendon have proven to be a valid but expensive and stationary diagnostic tool. In this study, a new mobile NMR sensor was to be tested in the evaluation of the Achilles tendon. METHOD: The technical development of the so-called NMR-MOUSE ( Mobile Universal Surface Explorer) represents a novelty with an open and portable sensor. To appraise its diagnostic efficacy, healthy athletes (professional soccer players, track and field, as well as aquatic athletes), healthy controls and patients with Achilles tendon lesions were evaluated. As an accessible, sensitive and reproducible parameter for the study the transverse relaxation time T2 with its angular dependency was chosen. As part of the examination, the relaxation times of the skin, the tendon and the surrounding soft tissue were determined. RESULTS: During the evaluation with the NMR-MOUSE, the skin and peritendineous tissue exhibited relatively long T2 relaxation times, while the tendon itself had significantly shorter T2 times, allowing for a clear differentiation of the structures. The T2 relaxation time of the Achilles tendon in the control group averaged 5.8 ms. The MRI-MOUSE was able to demonstrate an increase in the T2 relaxation times in patients with pathological lesions of the tendon due to the increased water retention of the tissue. CONCLUSION: The novel NMR-MOUSE represents a cost efficient and portable sensor, which allows for a reliable evaluation of surface structures, such as the Achilles tendon. The anisotropic structure of the tendon and the surrounding soft tissue can be reliably differentiated with the help of the NMR-MOUSE.

Achilles Tendon↗