Chronic middle ear disease and cochlear implantation.

We have presented three patients with bilateral CSOM who were otherwise suitable for cochlear implantation. These patients had conventional surgical management of CSOM and were implanted after a period of 6 months through apparently healthy middle ears. However, all three had a recurrence of middle ear disease requiring further surgery, and one had a potentially life-threatening complication necessitating removal of the implant. Before considering cochlear implantation in patients with bilateral CSOM, it is essential to eradicate all disease, and radical mastoidectomy with obliteration may be necessary. The use of a cochlear sealing device may further ensure prevention of infection spreading into the cochlea.

Aged

Cochlear pathology following reimplantation of a multichannel scala tympani electrode array in the macaque.

The histopathologic consequence of removing and reimplanting intracochlear electrode arrays on residual auditory nerve fibers is an important issue when evaluating the safety of cochlear prostheses. The authors have examined this issue by implanting multichannel intracochlear electrodes in macaque monkeys. Macaques were selected because of the similarity of the surgical technique used to insert electrodes into the cochlea compared to that in humans, in particular the ability to insert the arrays into the upper basal turn. Five macaques were bilaterally implanted with the Melbourne/Cochlear banded electrode array. Following a minimum implant period of 5 months, the electrode array on one side of each animal was removed and another immediately implanted. The animals were sacrificed a minimum of 5 months following the reinsertion procedure, and the cochleas prepared for histopathologic analysis. Long-term implantation of the electrode resulted in a relatively mild tissue response within the cochlea. Results also showed that inner and outer hair cell survival, although significantly reduced adjacent to the array, was normal in 8 of the 10 cochleas apicalward. Moreover, the electrode reinsertion procedure did not appear to adversely affect this apical hair cell population. Significant new bone formation was frequently observed in both control and reimplanted cochleas close to the electrode fenestration site and was associated with trauma to the endosteum and/or the introduction of bone chips into the cochlea at the time of surgery. Electrode insertion trauma, involving the osseous spiral lamina or basilar membrane, was more commonly observed in reimplanted cochleas. This damage was usually restricted to the lower basal turn and resulted in a more extensive ganglion cell loss. Finally, in a number of cochleas part of the electrode array was located within the scala media or scala vestibuli. These electrodes did not appear to evoke a more extensive tissue response or result in more extensive neural degeneration compared with electrodes located within the scala tympani. In conclusion, the present study has shown that the reimplantation of a multichannel scala, tympani electrode array can be achieved with minimal damage to the majority of cochlear structures. Increased insertion trauma, resulting in new bone formation and spiral ganglion cell loss, can occur in the lower basal turn in cases where the electrode entry point is difficult to identify due to proliferation of granulation and fibrous tissue.

Animals

Factors predicting postoperative sentence scores in postlinguistically deaf adult cochlear implant patients.

A sample of 64 postlinguistically profoundly to totally deaf adult cochlear implant patients were tested without lipreading by means of the Central Institute for the Deaf (CID) sentence test 3 months postoperatively. Preoperative promontory stimulation results (thresholds, gap detection, and frequency discrimination), age, duration of profound deafness, cause of deafness, lipreading ability, postoperative intracochlear thresholds and dynamic ranges for electrical stimulation, depth of insertion of the electrode array into the scala tympani, and number of electrodes in use were considered as possible factors that might be related to the postoperative sentence scores. A multiple regression analysis with stepwise inclusion of independent variables indicated that good gap detection and frequency discrimination during preoperative promontory testing, larger numbers of electrodes in use, and greater dynamic ranges for intracochlear electrical stimulation were associated with better CID scores. The CID scores tended to decrease with longer periods of profound deafness.

Adolescent

Surgical complications with the cochlear multiple-channel intracochlear implant: experience at Hannover and Melbourne.

The surgical complications for the first 153 multiple-channel cochlear implant operations carried out at the Medizinische Hochschule in Hannover and the first 100 operations at the University of Melbourne Clinic, The Royal Victorian Eye and Ear Hospital, are presented. In the Hannover experience the major complications were wound breakdown, wound infection, electrode tie erosion through the external auditory canal, electrode slippage, a persistent increase in tinnitus, and facial nerve stimulation. The incidence of wound breakdown requiring removal of the package was 0.6% in Hannover and 1.0% in Melbourne. The complications for the operation at both clinics were at acceptable levels. It was considered that wound breakdown requiring implant removal could be kept to a minimum by making a generous incision and suturing the flap without tension.

Australia

The biologic safety of the Cochlear Corporation multiple-electrode intracochlear implant.

Studies have been undertaken to confirm the biologic safety of the Cochlear Corporation multi-electrode intracochlear implant. The materials used are biocompatible. The electrode array is flexible: it can be inserted with minimal or no trauma, providing the insertion is stopped when resistance is first felt. An atraumatic insertion is facilitated if a good view is obtained along the scala tympani of the basal turn of the cochlea by drilling through the crista fenestrae. The passage of the electrode around the cochlea can be facilitated if the electrode is rotated during insertion (clockwise for the left and anticlockwise for the right cochlea). The electrode can be explanted and another one reinserted with minimal or no trauma. A seal established around the electrode after an implantation period of 2 weeks can prevent infection extending from the middle to the inner ear. The electrical stimulus parameters produced by the Nucleus receiver-stimulator cause no loss of spiral ganglion cells or corrosion of the platinum band electrodes. Long-term stimulation has been carried out for up to 8 years in patients without affecting their clinical performance.

Animals

A multiple-electrode intracochlear implant for children.

A multiple-electrode intracochlear implant that provides 21 stimulus channels has been designed for use in young children. It is smaller than the adult version and has magnets to facilitate the attachment of the headset. It has been implanted in two children aged 5 and 10 years. The two children both lost hearing in their third year, when they were still learning language. Following implantation, it was possible to determine threshold and comfortable listening levels for each electrode pair. This was facilitated in the younger child by prior training in scaling visual and electrotactile stimuli. Both children are regular users of the implant, and a training and assessment program has been commenced.

Child

The University of Melbourne--nucleus multi-electrode cochlear implant.

To summarize, our preliminary results indicate that some prelingually deaf patients may get worthwhile help from a multiple-electrode cochlear implant which extracts formants. They can understand words and running speech better when using the cochlear implant with lip-reading compared to lip-reading alone. It has been encouraging that these improvements can occur in young adults and teenagers. It has also been encouraging that some can recognize place pitch as well as rate pitch. There are, however, considerable variations in performance and this may be due to the following factors: whether they have had some hearing after birth, the method of education used, the motivation of the patient and age at implantation. In conclusion it is important to emphasize that deaf children are severely disadvantaged however good their teacher of the deaf. Research on cochlear implants offers hope for profoundly-totally deaf children. These developments will not replace the caring, competent educators but complement their skills. There is also a greater need than ever for an interdisciplinary approach to these children.

Animals

Preliminary results for the cochlear corporation multielectrode intracochlear implant in six prelingually deaf patients.

The preliminary results from this study indicate that some prelingually deaf patients may get worthwhile help from a multiple-electrode cochlear implant that uses a formant-based speech processing strategy. It is encouraging that these improvements can occur in young adults and teenagers. The results for two children are also encouraging. A 10-year-old child obtained significant improvement on some speech perception tests. It was easy to set thresholds and comfortable listening levels on a 5-year-old child, and he is now a regular user of the device. There are, however, considerable variations in performance among the prelingual patients, which may be related to the following factors: whether they have had some hearing after birth, the method of education used, the motivation of the patient, and age at implantation.

Adolescent

Clinical trial of a multi-channel cochlear prosthesis: results on 10 postlingually deaf patients.

The clinical trial of a multi-channel cochlear prosthesis has been carried out on 10 profoundly-totally deaf adult patients. Speech perception tests have shown that all the patients received significant benefit from the device. They obtained improvements in understanding running speech from 47% to 550% when using the device in conjunction with lipreading compared to lipreading alone. With an open-set CID sentence test, three patients obtained scores showing an ability to understand speech without the need to lipread, and a further three patients had scores indicating they could also receive useful information without lipreading. In two patients, very limited open-set scores for electrical stimulation alone were obtained. This was most probably due to the fact that only a few channels of stimulation were possible due to cochlear disease, and they were therefore receiving information more like a single-channel device. The prosthesis has also been found to provide considerable help in hearing and recognizing everyday sounds.

Adult

Implanted material tolerance studies for a multiple-channel cochlear prosthesis.

We have performed a number of temporal bone and animal studies in order to evaluate the histopathological effects of intracochlear electrode implantation and chronic electrical stimulation. Our results indicate that (a) the insertion of a free-fit scala tympani array results in minimal damage to the membranous labyrinth; (b) the materials used in the electrode array evoke mild tissue reactions when implanted subcutaneously, in muscle, or within the scala tympani; (c) intracochlear electrical stimulation for periods of 500 to 2000 hours, using carefully controlled biphasic pulses, does not adversely affect the population or neural activity of the primary auditory neurones; (d) labyrinthine infection severely reduces the number of viable spiral ganglion cells; (e) an adequate fibrous tissue seal of the round window can prevent the spread of infection from the bulla to the implanted cochlea in cats, following inoculation of the bulla cavity with bacteria; (f) bone growth is not associated with electrical stimulation per se; (g) the electrode arrays show minimal platinum dissolution and no apparent degradation of the Silastic carrier following periods of long-term intracochlear electrical stimulation.

Animals