Coronary grafts flow and cardiac pacing modalities: how to improve perioperative myocardial perfusion.

OBJECTIVE: Aim of this study was to investigate modifications of coronary grafts flow during different pacing modalities after CABG. MATERIALS AND METHODS: Two separate prospective studies were conducted in patients undergoing CABG and requiring intraoperative epicardial pacing. In a first study (22 patients) coronary grafts flows were measured during dual chamber pacing (DDD) and during ventricular pacing (VVI). In a second study (10 patients) flows were measured during DDD pacing at different atrio-ventricular (A-V) delay periods. A-V delay was adjusted in 25 ms increments from 25 to 250 ms and flow measurements were performed for each A-V delay increment. A transit time flowmeter was used for the measurements. RESULTS: An average of 3.4 grafts/patient were performed. In the first study, average coronary graft flow was 47.4+/-20.8 ml/min during DDD pacing and 41.8+/-18.2 ml/min during VVI pacing (P = 0.0004). Furthermore average systolic pressure was 94.3+/-10.1 mmHg during DDD pacing and 89.6+/-12.2 mmHg during VVV pacing (P = 0.0007). No significant differences in diastolic pressure were recorded during the two different pacing modalities. In the second study, maximal flows were achieved during DDD pacing with an A-V delay of 175 ms (54+/-9.6 ml/min) and minimal flows were detected at 25 ms A-V delay (38.1+/-4.7 ml/min) (P=ns). No significant differences in systolic or diastolic blood pressure were noticed during the different A-V delays. CONCLUSION: Grafts flowmetry provides an extra tool to direct supportive measures such as cardiac pacing after CABG. DDD mode with A-V delay around 175 ms. should be preferred to allow for maximal myocardial perfusion via the grafts.

Cardiac Pacing, Artificial↗

A new specifically designed forceps for chest drain insertion.

Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

Adolescent↗